EEWORLDEEWORLDEEWORLD

Part Number

Search

232-103-H7FT22-55PE-03

Description
Circular Connector Adapter, 55 Contact(s), Carbon Steel, Male-Female
CategoryThe connector    The connector   
File Size435KB,1 Pages
ManufacturerGlenair
Websitehttp://www.glenair.com/
Download Datasheet Parametric View All

232-103-H7FT22-55PE-03 Overview

Circular Connector Adapter, 55 Contact(s), Carbon Steel, Male-Female

232-103-H7FT22-55PE-03 Parametric

Parameter NameAttribute value
Reach Compliance Codecompli
Other featuresSTANDARD: MIL-DTL-38999
Connector typeCIRCULAR CONNECTOR ADAPTER
Contact point genderMALE-FEMALE
Coupling typeBAYONET
DIN complianceNO
empty shellNO
Filter functionNO
IEC complianceNO
MIL complianceYES
Manufacturer's serial number232-103-H7
Mixed contactsNO
Installation typePANEL
OptionsHERMETIC
Shell surfaceTIN
Shell materialCARBON STEEL
Total number of contacts55
Base Number Matches1
232-103-H7
Jam Nut Mount Hermetic Bulkhead Feed-Thru
MIL-DTL-38999 Series II Type
Connector Series
232
-
D38999 Series II Type
Shell Style
H7
- Jam Nut Mount
Shell Size
08
10
12
14
16
18
20
22
24
Insert Arrangement
Per MIL-DTL-38999 Series II
MIL-STD-1560
Alternate Key
Position
A, B, C, D
(N = Normal)
1.69 Max
.915 REF
B TYP
232
-
103
-
H7 Z1 10
-
35 P N
-
01
Connector Type
103
-
Hermetic Bulkhead
Feed-Thru
Connector Material and Finish
FT
- Carbon Steel, Fused Tin
Z1
- CRES, Passivated
ZL
- CRES, Nickel Finish
A Thread
Hole for .032 DIA Safety
Wire, 3 Equally Spaced
.125
.150 Max
Contact Termination
P
- Pin on Jam Nut Side
S
- Socket on Jam Nut Side
Panel Accom.
E Dia
Panel Accomodation
01
- .0625″ (Min) .125″ (Max)
02
- .0625″ (Min) .250″ (Max)
03
- .0625″ (Min) .500″ (Max)
F
Recommended Panel Cut-Out
TABLE I: CONNECTOR DIMENSIONS
SHELL
SIZE
08
10
12
14
16
18
20
22
24
A THREAD
CLASS 2A
.875-20 UNEF
1.000-20 UNEF
1.125-18 UNEF
1.250-18 UNEF
1.375-18 UNEF
1.500-18 UNEF
1.625-18 UNEF
1.750-18 UNS
1.875-16 UN
B DIA
MAX
.474(12.0)
.591(15.0)
.751(19.1)
.876(22.3)
1.001(25.4)
1.126(28.6)
1.251(31.8)
1.376(35.0)
1.501(38.1)
C
HEX
1.062(27.0)
1.188(30.2)
1.312(33.3)
1.438(36.5)
1.562(39.7)
1.688(42.9)
1.812(46.0)
2.000(50.8)
2.125(54.0)
D
FLATS
1.250(31.8)
1.375(34.9)
1.500(38.1)
1.625(41.3)
1.781(45.2)
1.890(48.0)
2.016(51.2)
2.140(54.4)
2.265(57.5)
E DIA
±.005(0.1)
.885(22.5)
1.010(25.7)
1.135(28.8)
1.260(32.0)
1.385(35.2)
1.510(38.4)
1.635(41.5)
1.760(44.7)
1.885(47.9)
F +.000-.005
(0-0.1)
.830(21.1)
.955(24.3)
1.085(27.6)
1.210(30.7)
1.335(33.9)
1.460(37.1)
1.585(40.3)
1.710(43.4)
1.835(46.6)
C
D
Insert Arrangement per
MIL-DTL-38999, Series Il
MIL-STD-1560
APPLICATION NOTES
1.
2.
3.
Power to a given contact on one end will result in power to contact directly
opposite, regardless of identification letter.
Hermeticity = less than 1 x 10
-4
cc/sec at one atmosphere. Not for use in liquid
atmosphere.
Material/finish:
Shell, nut – CRES/passivated, carbon steel/fused tin or CRES/nickel per QQ-N-290.
4.
Contacts – Gold Plated. Pin: alloy 52; Skt.: copper alloy
Insulator – fused vitreous glass/N.A.
Seals – fluorosilicone rubber/N.A.
Metric dimensions (mm) are indicated in parentheses.
© 2008 Glenair, Inc.
www.glenair.com
CAGE CODE 06324
Printed in U.S.A.
E-Mail: sales@glenair.com
GLENAIR, INC.
1211 AIR WAY
GLENDALE, CA 91201-2497
818-247-6000
FAX 818-500-9912
E-7
Bulkhead
Feed-Thrus
E
Can a three-phase 380V inverter be connected to two live inputs? Or one live and one neutral?
Three-phase 380V inverter input: 1. Can I connect two-phase live wires to debug parameters (but not run)? 2. Can I connect two-phase live wires to run? 3. Can I connect 1 fire and 1 zero to debug para...
eeleader Industrial Control Electronics
HMI Special Topic: Basic Functions and Selection Indicators of Three-Person Machine Interface Products
Basic functions and selection indicators of human-machine interface products Basic functions:  equipment working status display, such as indicator lights, buttons, text, graphics, curves, etc.  Data a...
蓝色心情 DSP and ARM Processors
About infrared optical communication
This design implements a voice and data infrared transmission system. It uses PCM codec to get digital voice. FPGA device is used as the main control unit to multiplex and encode the room temperature ...
sumanhu FPGA/CPLD
How to make high voltage pulse power supply
RT power supply: -200~40 Frequency: 1KHZ Duty cycle adjustable 30PF load Please give me some advice, thank you!...
chencl Power technology
Can't find boot.hv when compiling PB?
I added boot.hv to the .bib file: FILES boot.hv $(_FLATRELEASEDIR)\boot.hv XIPKERNEL SH default.hv $(_FLATRELEASEDIR)\default.hv XIPKERNEL SH user.hv $(_FLATRELEASEDIR)\user.hv XIPKERNEL SH However, w...
tanling79467240 Embedded System
How to write image files to ARM
I am now doing some experiments on the ARM7 development board, but the experimental tutorial does not tell me how to generate an image file from the compiled C language program and how to write it int...
gjfzb ARM Technology

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2224  575  1231  2347  2705  45  12  25  48  55 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号