DCMC342T550DN2B

Description
aluminum electrolytic capacitors - screw terminal 550v 3400uf case 3.00 X 7.625in
CategoryPassive components   
File Size327KB,16 Pages
ManufacturerAll Sensors
Environmental Compliance
Download Datasheet Parametric View All

DCMC342T550DN2B Overview

aluminum electrolytic capacitors - screw terminal 550v 3400uf case 3.00 X 7.625in

DCMC342T550DN2B Parametric

Parameter NameAttribute value
ManufactureCornell Dubilie
Product CategoryAluminum Electrolytic Capacitors - Screw Terminal
RoHSYes
Capacitance3400 uF
Voltage Rating DC550 V
Tolerance- 10 %, + 50 %
Minimum Operating Temperature- 40 C
Maximum Operating Temperature+ 85 C
Load Life2000 h
Diamete76 mm (3 in)
Length194 mm (7.625 in)
Lead Spacing31.75 mm (1.25 in)
PackagingBulk
ProducComputer Grade Electrolytic Capacitors
Termination StyleScrew
Type DCMC 85 °C High Capacitance, Screw Terminal, Aluminum
Highest Capacitance Screw Terminal Type
With more capacitance and often more ripple-current capabilty than
the best-value Type 3186 capacitor, the Type DCMC capacitor is the
better choice for high-capacitance, power supply filters and energy
storage applications such as welding equipment,UPS systems and
computer hold-up power. The extended cathode foil of the DCMC
assures cool operation with heatflow from the capacitor element to
the can.
Highlights
Specifications
Temperature Range
Capacitance Range
Capacitance Tolerance
Leakage Current
Ripple Current Multipliers
- Highest capacitance value
- Right for Power Supply and UPS systems
- Thermal-Pak™ extended cathode construction
–40 °C to +85 °C
6.3 Vdc to 550 Vdc
110 µF to 2.7 F
–10% +75% ≤ 100 Vdc
–10% +50% ≥ 160 Vdc
≤ 6 √CV µA, 6 mA max, at 5 min
Ambient Temperature
45 °C
2.24
Frequency
50 Hz 60 Hz 120 Hz 360 Hz 1 kHz 5 kHz
1 3/8” & 1 3/4”
Diameters
6.3 to 160 V
200 to 350 V
400 to 550 V
2” & 2 1/2”
Diameters
6.3 to 160 V
200 to 350 V
400 to 550 V
3” & 3 1/2”
Diameters
6.3 to 160 V
200 to 350 V
400 to 550 V
0.92
0.80
0.78
0.93
0.81
0.79
0.95
0.85
0.82
0.94
0.85
0.83
0.95
0.87
0.83
0.96
0.88
0.84
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.05
1.17
1.20
1.04
1.13
1.17
1.02
1.08
1.13
1.10
1.30
1.35
1.07
1.20
1.26
1.04
1.12
1.20
1.10
1.30
1.36
1.11
1.24
1.30
1.05
1.14
1.24
55 °C
2.00
65 °C
1.73
75 °C
1.41
85 °C
1.00
10 kHz
& up
1.12
1.32
1.40
1.12
1.26
1.34
1.05
1.17
1.27
Specifications
Rated Voltage Range
Low Temperature Characteristics
I
mpedance ratio: Z
–20⁰C
∕ Z
+25⁰C
≤ 20 (6.3–10 Vdc)
≤ 8 (16–50 Vdc)
≤ 4 (63–100 Vdc)
≤ 3 (150–550 Vdc
)
Endurance Life Test
2000 h @ full load at 85 °C
∆ Capacitance ±20%
ESR 200% of limit
DCL 100% of limit
500 h @ 85 °C
Capacitance 100% of limit
ESR 100% of limit
DCL 100% of limit
5 to 55 Hz, 0.06” and 10 g max, 1.5 h each of 2 axes
RoHS Compliant
Shelf Life Test
Vibration
CDM Cornell Dubilier • 140 Technology Place • Liberty, SC 29657 • Phone: (864)843-2277 • Fax: (864)843-3800
io port reading and writing problems
I can use open to open /dev/port, and then lseek to a certain io port, but where can I find the address of this io port? In which header files is it generally defined? Thank you...
chunlei9924 Embedded System
Multifunctional handheld oscilloscope function meter (CN0002, CN0156)
I've been very busy recently, haha, with final exams, smart cars, and the national competition. I only had one free day today, but I wrote eight papers in one day, so I didn't have time to go to the f...
梦之旅 ADI Reference Circuit
Please help me with the question of checking the register
CCS software simulation can be used to view and change the value of the CPU register.When running the program in single step during online simulation on the board, it is found that the program cannot ...
小威 Analogue and Mixed Signal
2812 Compilation Problem
[Linking...] "C:\CCStudio_v3.3PLA\C2000\cgtools\bin\cl2000" -@"Debug.lkf"fatal error: file "C:\\DSPcx\\test\ts2800.lib" specifies ISArevision "C2700", which is not compatible with ISA revision "C2800"...
1955521136 DSP and ARM Processors
Problems with using chipscope
My version is 11.1. When using chipscope, I use the method of inserting cdc, inserting ila, connecting the signal, generating a bit file, entering analyze, scanning jtag chain, and there is no problem...
jg4012 FPGA/CPLD
MSP430G2553 ultrasonic ranging cannot enter interrupt
Now it is displayed.....cm Timer A did not enter the interrupt. I want to know where the problem is and how to fix it. I am a newbie and I am in a hurry. Graduation project #include#include #include u...
andsk88 Microcontroller MCU

Technical ResourceMore

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 874  520  2771  1372  563  18  11  56  28  12 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号