EEWORLDEEWORLDEEWORLD

Part Number

Search

2635LHA214000LI

Description
Rocker Switch, (on)-on, Momentary, 8A, 24VDC, Screw Terminal, Rocker Actuator, Panel Mount
CategoryMechanical and electronic products    switch   
File Size333KB,8 Pages
ManufacturerAPEM
Download Datasheet Parametric View All

2635LHA214000LI Overview

Rocker Switch, (on)-on, Momentary, 8A, 24VDC, Screw Terminal, Rocker Actuator, Panel Mount

2635LHA214000LI Parametric

Parameter NameAttribute value
Objectid312907977
Reach Compliance Codecompliant
Country Of OriginUK
ECCN codeEAR99
YTEOL9.1
Actuator colorGRAY
Actuator length0.354 inch
Actuator materialPOLYAMIDE
Actuator typeROCKER
body width24.9936 mm
body height16.9926 mm
Body length or diameter32.004 mm
center contact materialSILVER
Contact (AC) maximum rated R load10A@250VAC
Maximum contact current (AC)10 A
Maximum contact current (DC)8 A
Contact (DC) maximum rated R load8A@24VDC
Contact function(ON)-ON
Contact resistance0.01 mΩ
Maximum contact voltage (AC)250 V
Maximum contact voltage (DC)24 V
Dielectric withstand voltage2500VRMS V
Electrical life10000 Cycle(s)
End contact materialSILVER
Shell materialPOLYAMIDE
Insulation resistance1000000000 Ω
Manufacturer's serial number2600
Installation featuresPANEL MOUNT
Maximum operating temperature85 °C
Minimum operating temperature-20 °C
surface mountNO
Switch actionMOMENTARY
Switch typeROCKER SWITCH
Terminal length0.437 inch
Termination typeSCREW
2600 series
Power rocker switches
Distinctive features and specifications
Three rocker shapes : plain, V-shaped or concave
Various rocker colours
Frame with protection guard on 2600LP models
Illuminated or non-illuminated
UL, CSA, VDE and NF (EN 61058-1) approved
ELECTRICAL SPECIFICATIONS
• Max. current/voltage rating with resistive load and approved ratings : see table below.
• Initial contact resistance : 10mΩ max.
• Insulation resistance : 1.000 MΩ min. at 500VDC
• Dielectric strength : 2.500 Vrms 50 Hz min. between terminals
3.000 Vrms 50 Hz min. between terminals and metal panel
• Electrical life : 10.000 cycles at full load
APPROVED RATINGS
FUNCTIONS
CSA (double pole)
CSA 22-2
DIRECT CURRENT
NF
EN 61058-1
UL (double pole)
UL 1054
VDE
EN 61058-1
24 VDC
12 VDC
D
ON - OFF
ON - ON
1/6 HP 125VAC
16A 125VAC
16A 250VAC
1/3 HP 250VAC
10A 125VAC
10A 250VAC
1/6 HP 125/250VAC
-
10A 125VAC
10A 250VAC
1/6 HP 250VAC
1/6 HP 125VAC
16A 125VAC
16A 250VAC
1/3 HP 250VAC
10A 125VAC
10A 250VAC
1/6 HP 125/250VAC
-
-
10(4)A 250VAC
T 85/55
-
10A
15A
ON - OFF - ON
ON - ON - ON
OTHERS
L I option
10(4)A 250VAC
-
L I option
10(4)A 250VAC
L I option
10(4)A 250VAC
-
L I option
10(4)A 250VAC
8A
5A
8A
10A
8A
10A
MATERIALS
GENERAL SPECIFICATIONS
• Case : melamine/polyester
• Frame : polyamide
• Actuator : polyamide
• Contacts :
A
: silver
C
: copper, silver plated
• Panel thickness : 0,8 mm to 4 mm (.031 to .157)
• Operating temperature :
- silver contacts (A) : -20°C to +85°C
- silver plated contacts (C) : -10°C to +55°C
AGENCY APPROVALS
EN 61058-1
EN 61058-1
Availability
: consult factory for details of approved models.
Marking
: approved models are standard marked.
APEM
www.apem.com
D-45
Guidance: What should I learn if I want to develop in the hardware field in the electronic information major?
I am a student majoring in electronic information and I want to study for a master's degree. I personally prefer hardware-related things and hate programming. Although hardware also requires programmi...
zhaolequan Embedded System
Common protection circuit design
Protection circuit design...
tonytong Power technology
PCB production of nRF905
I am now drawing a nRF905 module circuit. Anyone who has personally made nRF905 PCB can give me some help? Now I have some questions: Does this support 433, 868 and 915 frequency bands? It seems that ...
melodyooo RF/Wirelessly
Dual-channel data acquisition based on ARM
The input end is connected to a function signal generator. How do I write square waves, sine waves, triangle waves, etc. based on LM3S9B96 and display them on the screen?...
L_古斯 ARM Technology
s7-200 programming cable problem
I have many Siemens PLCs that use S7-200, but I don't have a programming cable. Now some machines need programming. I have a RS232-RS485 converter for Siwei inverters. I don't know if it can be used o...
eeleader Industrial Control Electronics
Typical Questions about Clock Gating
In my design , the main internal working clock is provided after the reset is cancelled. My original design expected that when the reset is cancelled, all flip-flops would be asynchronously reset to a...
eeleader-mcu FPGA/CPLD

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 105  1952  165  144  16  3  40  4  1  42 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号