Ordering Information .................................................................................................................................................................... 2
Dimensions and Patterns ― 3.2 x 2.5 mm................................................................................................................................. 14
Dimensions and Patterns ― 5.0 x 3.2 mm................................................................................................................................. 14
Dimensions and Patterns ― 7.0 x 5.0 mm................................................................................................................................. 15
Additional Information ................................................................................................................................................................ 16
Revision History ......................................................................................................................................................................... 17
Rev 1.07
Page 3 of 17
www.sitime.com
SiT3372
1 MHz to 220 MHz Ultra-low Jitter Differential VCXO
Electrical Characteristics
Table 2. Electrical Characteristics – Common to LVPECL, LVDS and HCSL
All Min and Max limits in the Electrical Characteristics tables are specified over temperature and rated operating voltage with standard
output termination shown in the termination diagrams. Typical values are at 25°C and nominal supply voltage.
Parameter
Output Frequency Range
Frequency Stability
Symbol
f
F_stab
Min.
1
-15
-25
-35
-50
Operating Temperature Range
T_use
-20
-40
-40
-40
Supply Voltage
Vdd
2.97
2.7
2.52
2.25
Pull Range
PR
Typ.
–
–
–
–
–
–
–
–
–
3.3
3.0
2.8
2.5
Max.
220
+15
+25
+35
+50
+70
+85
+95
+105
3.63
3.3
3.08
2.75
Unit
MHz
ppm
ppm
ppm
ppm
°C
°C
°C
°C
V
V
V
V
ppm
See the APR (Absolute Pull Range)
Table 11.
Contact SiTime
for custom pull range options
Voltage at which maximum frequency deviation is guaranteed
Voltage at which minimum frequency deviation is guaranteed
Contact SiTime
for other input bandwidth options
Extended Industrial
Extended Commercial
Industrial
Condition
Accurate to 6 decimal places
Inclusive of initial tolerance, operating temperature, rated power
supply voltage, load variations, and first year aging at 25
°C,
with VIN voltage at Vdd/2.
±15
ppm is only guaranteed for pull range up to
±100
ppm.
Frequency Range
Frequency Stability
Temperature Range
Supply Voltage
Voltage Control Characteristics
±25, ±50, ±80, ±100, ±150,
±200, ±400, ±800, ±1600,
±3200
90%
–
–
–
–
–
–
10
10
–
–
10%
–
–
1.0
–
Input Characteristics
Input Voltage High
Input Voltage Low
Input Pull-up Impedance
Duty Cycle
Startup Time
OE Enable/Disable Time
VIH
VIL
Z_in
DC
T_start
T_oe
70%
–
–
45
–
–
–
–
100
–
–
–
–
30%
-
55
3.0
3.8
Vdd
Vdd
kΩ
%
ms
µs
Measured from the time Vdd reaches its rated minimum value
f = 156.25 MHz. Measured from the time OE pin reaches
rated VIH and VIL to the time clock pins reach 90% of swing
and high-Z. See
Figure 9
and
Figure 10
Pin 2, OE
Pin 2, OE
Pin 2, OE logic high or logic low
Upper Control Voltage
Lower Control Voltage
Control Voltage Input Impedance
Control Voltage Input Bandwidth
Pull Range Linearity
Frequency Change Polarity
VC_U
VC_L
VC_z
V_c
Lin
–
Vdd
Vdd
MΩ
kHz
%
Positive Slope
Output Characteristics
Startup and OE Timing
Rev 1.07
Page 4 of 17
www.sitime.com
SiT3372
1 MHz to 220 MHz Ultra-low Jitter Differential VCXO
Table 3. Electrical Characteristics – LVPECL Specific
Parameter
Current Consumption
OE Disable Supply Current
Output Disable Leakage Current
Maximum Output Current
Output High Voltage
Output Low Voltage
Output Differential Voltage Swing
Rise/Fall Time
RMS Period Jitter
[4]
RMS Phase Jitter (random)
Symbol
Idd
I_OE
I_leak
I_driver
VOH
VOL
V_Swing
Tr, Tf
T_jitt
T_phj
Min.
–
–
–
–
Vdd-1.15
Vdd-2.0
1.2
–
–
–
Typ.
78
53
0.15
–
–
–
1.6
225
1.0
0.225
Max.
92
61
–
33
Vdd-0.7
Vdd-1.5
2.0
290
1.6
0.270
Unit
mA
mA
A
mA
V
V
V
ps
ps
ps
Condition
Excluding Load Termination Current, Vdd = 3.3 V or 2.5 V
OE = Low
OE = Low
Maximum average current drawn from OUT+ or OUT-
See
Figure 5
See
Figure 5
See
Figure 6
20% to 80%, see
Figure 6
f = 100, 156.25 or 212.5 MHz, Vdd = 3.3 V or 2.5 V
f = 156.25 MHz, Integration bandwidth = 12 kHz to 20 MHz, all
Vdd levels, includes spurs, pull range =
±100
ppm. Temperature
ranges -20 to 70°C and -40 to 85°C
f = 156.25 MHz, Integration bandwidth = 12 kHz to 20 MHz, all
Vdd levels, includes spurs, pull range =
±100
ppm. Temperature
ranges -40 to 95°C and -40 to 105°C
f = 156.25 MHz, IEEE802.3-2005 10 GbE jitter mask integration
bandwidth = 1.875 MHz to 20 MHz, includes spurs, all Vdd
levels
f = 100, 156.25 or 212.5 MHz, Vdd = 3.3 V or 2.5 V
f = 156.25 MHz, Integration bandwidth = 12 kHz to 20 MHz, all
Vdd levels, includes spurs, pull range =
±100
ppm. Temperature
ranges -20 to 70°C and -40 to 85°C
f = 156.25 MHz, Integration bandwidth = 12 kHz to 20 MHz, all
Vdd levels, includes spurs, pull range =
±100
ppm. Temperature
ranges -40 to 95°C and -40 to 105°C
f = 156.25 MHz, IEEE802.3-2005 10 GbE jitter mask integration
bandwidth = 1.875 MHz to 20 MHz, includes spurs, all
My development environment is VS2008. I want to write a program for operating the GPIO of S3C2440 under WinCE. How should I write it? For example, if I want to operate a certain pin of GPB, how should...
[i=s]This post was last edited by dontium on 2014-5-11 17:30[/i] I originally used E-coins to buy a scanner, and originally planned to scan the books in the bookcase and save them. Today I was free, s...
[i=s]This post was last edited by paulhyde on 2014-9-15 03:13[/i] I have been working on program-controlled filtering recently, so I have collected some information and papers for your reference. This...
A program I wrote before used template classes. All definitions and implementations of the template classes were in the same h file, compiled with the -frepo switch. It worked fine before, but today I...
My hardware schematic is as follows: Please feel free to open it! http://www.dzjia.cn/html/jiejuefangan/20070619/24939_2.html As shown in the figure: P2.7 is connected to the NCS chip select pin of RC...
PV DC fuses are safety devices used to protect PV panels, inverters, and DC loads. To ensure their safety and reliability, they must be UL248 certified.
Before applying for UL248 certifi...[Details]
Electric vehicles are currently gaining momentum, but this is just a facade. Fuel-powered vehicles remain unchallenged. While electric vehicles boast unique advantages in environmental emissions an...[Details]
With the rapid advancement of automation technology, collaboration between robots is no longer just science fiction. Imagine dozens of machines moving goods in a warehouse without interfering with ...[Details]
Learned the following information.
Customer product: industrial computer motherboard
Glue application area: CPU/BGA filling
Glue color requirements: black or t...[Details]
In daily life, power transformers have different functions and uses due to different usage scenarios. The most common ones can be divided into: control transformers, isolation transformers, rectifi...[Details]
Common methods for troubleshooting roller press bearing wear include repair welding, thermal spraying, brush plating, and scrapping and replacement. However, these methods are often subject to asse...[Details]
Electric vehicles will revolutionize transportation, changing fuel consumption, carbon emissions, costs, maintenance, and driving habits. Currently, a major selling point for electric vehicles is t...[Details]
introduction
With the development of society, people's requirements for the quality of refrigerated and frozen foods are constantly improving. The changes in food appearance and nutritional co...[Details]
In this final installment of a five-part blog series, I will discuss noise in op amps driving headphone loads and some techniques for reducing it. Previous posts have discussed headphone load power...[Details]
The Radxa Cubie A7A is a single-board computer (SBC) powered by the Allwinner A733 octa-core Cortex-A76/A55 SoC, equipped with a 3 TOPS AI accelerator and up to 16GB of LPDDR5 memory.
Fo...[Details]
As the power density of modern electronic systems continues to increase, effective thermal management has become critical to ensuring system performance, reliability, and longevity—especially in hi...[Details]
The intelligent
dust monitoring system intelligently monitors dust concentrations at and around construction sites. All concentration values are transmitted to a cloud server for
cloud co...[Details]
The primary control objective in this case is the display and alarming of data parameters on the Xinheng control scale instrument. The system's main PLC uses a Siemens CPU, and data is collected vi...[Details]
Servo motors, also known as actuator motors, serve as actuators in automatic control systems, converting received electrical signals into angular displacement or angular velocity output on the moto...[Details]
The term "remote meter reading" literally emphasizes remoteness. But how far is remote? One kilometer? Two kilometers? Those aren't considered far at all. Currently, the longest distance for ...[Details]