EEWORLDEEWORLDEEWORLD

Part Number

Search

BC10ZC273JZJ1AA0

Description
Ceramic Capacitor, Multilayer, Ceramic, 10V, 5% +Tol, 5% -Tol, X7R, 15% TC, 0.027uF, Surface Mount, 1210, CHIP
CategoryPassive components    capacitor   
File Size141KB,8 Pages
ManufacturerAVX
Download Datasheet Parametric View All

BC10ZC273JZJ1AA0 Overview

Ceramic Capacitor, Multilayer, Ceramic, 10V, 5% +Tol, 5% -Tol, X7R, 15% TC, 0.027uF, Surface Mount, 1210, CHIP

BC10ZC273JZJ1AA0 Parametric

Parameter NameAttribute value
Objectid7110152357
package instruction, 1210
Reach Compliance Codecompliant
ECCN codeEAR99
YTEOL6.9
capacitance0.027 µF
Capacitor typeCERAMIC CAPACITOR
dielectric materialsCERAMIC
high1.02 mm
JESD-609 codee0
length3.2 mm
Installation featuresSURFACE MOUNT
multi-layerYes
negative tolerance5%
Number of terminals2
Maximum operating temperature125 °C
Minimum operating temperature-55 °C
Package formSMT
method of packingTR, Embossed, 7 Inch
positive tolerance5%
Rated (DC) voltage (URdc)10 V
size code1210
surface mountYES
Temperature characteristic codeX7R
Temperature Coefficient15% ppm/°C
Terminal surfaceTin/Lead (Sn60Pb40)
Terminal shapeWRAPAROUND
width2.5 mm
COTS Plus - BC Series
General Specifications
GENERAL DESCRIPTION
Extended range MLCCs for avionic, defense, and space applications have
been available from AVX for many years, typically to customer specification
control documents. The COTS PLUS - BC series now consolidates the main
test options into standard catalog offerings, eliminating the need to generate
custom specifications for each application. Key test options from MIL-PRF-
55681 are applied to BME and PME devices in NP0 and X7R temperature
characteristic dielectrics.
PRODUCT ADVANTAGES
• Higher CV capability than standard PME
• BME and PME technology
• Voltage Range up to 500V
APPLICATIONS
Defense/Aerospace
• Extended Range MLCC for all Applications
• Low weight/payload, small footprint
• Low Voltage Ratings to Maximize Capacitance for High Speed Decoupling
HOW TO ORDER
BC
Series
03
Size
02 = 0402
03 = 0603
05 = 0805
06 = 1206
10 = 1210
12 = 1812
13 = 1825
5
C
102
Capacitance
Code (In pF)
2 Sig. Digits +
Number of
Zeros
K*
Z
T
9
AA
1
Extened Test Level
0 = Not Applicable
1 = DPA IAW EIA-469
2 = 85/85 @ RV for 96 hours
3 = DPA and 85/85 @ RV
Dielectric
Voltage
Z = 10V A = C0G (NP0)
Y = 16V C = X7R
3 = 25V
5 = 50V
1 = 100V
2 = 200V
V = 250V
7 = 500V
Capacitance
Failure Rate
Termination
Tolerance
Z = COTS Plus T = 100% TN
B = ±.10 pF
B = Tin/Lead
C = ±.25 pF
(5% min Lead)
D = ±.50 pF
J = Tin/Lead (60/40)
F = ±1% (≥ 10 pF)
G = ±2% (≥ 10 pF)
J = ±5%
K = ±10%
M = ±20%
* B, C & D tolerance for ≤10 pF values.
Packaging
Base Group A Test Level
1 = 7" T&R
AA = Group A per MIL-PRF-55681
3 = 13" T&R
SA = Group A per MIL-PRF-55681
6 = Waffle Pack
with SLDC
(SLDC = Single Lot Date Code)
9 = Bulk
CONFORMANCE TEST LEVELS
Base Group A Test Options
Voltage Conditioning IAW MIL-PRF-55681
Elevated IR Sample
Visual and Mechanical Inspection
Solderability
Single Lot Date Code (SLDC)
Group A Data Summary
AA
SA
Extended Test Options
Not Applicable
DPA IAW EIA-469
85°C/85% RH @ Rated Voltage / 96 Hrs
DPA and 85/85 @ Rated Voltage
Code
0
1
2
3
081516
1
SPICE modeling and simulation of phase-locked loop
Good article, everyone take a look...
edelajiang Microchip MCU
Windows SDIO bus driver log
Hello everyone. I am developing an SDIO device and want to implement it as an SDIO device instead of SD memory. When I plug it into a PC running Windows XP, Windows recognizes it as a disk. When I try...
zhanp324 Embedded System
Fully automatic sound-activated strobe light
[i=s]This post was last edited by jameswangsynnex on 2015-3-3 20:02[/i]...
探路者 Mobile and portable
Serial port settings under Linux are urgent! !
I wrote a serial port program under Linux to send and receive data. The program is as follows: #include #include#include #include #include #include #include #include #include #include#includechar xCal...
etual1983 Linux and Android
When WinCE starts up automatically, how can I display my program interface directly without the desktop appearing?
I now use the registry to let my program (window program) start after gwes and explore. In this way, the desktop will appear for 2 or 3 seconds before my program appears. What should I do if I don't w...
ased30 The Industrial Cloud
Anyone who has used MAX038 as a signal source please come in! I need help, thank you.
The frequency of MAX038 is the capacitance value connected to the 5th pin multiplied by the input current of the 10th pin. Therefore, different frequency bands can be selected by connecting a capacito...
523335234 51mcu

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1083  2165  1262  717  939  22  44  26  15  19 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号