*Contact factory for SRC9000 Space Level SCD details.
For RoHS compliant products,
please select correct termination style.
TECHNICAL SPECIFICATIONS
Technical Data:
Capacitance Range:
Capacitance Tolerance:
Rated Voltage (V
R
)
Category Voltage (V
C
)
Surge Voltage (V
S
)
Surge Voltage (V
S
)
Temperature Range:
Unless otherwise specified, all technical data relate to an ambient temperature of 25°C
0.10 μF to 100 μF
±5%; ±10%; ±20%
4
6
10
15
20
25
35
50
2.7
4
6.7
10
13.3
16.7
23.3
33.3
5.3
8
13.3
20
26.7
33.3
46.7
66.7
3.5
5.3
8.7
13.3
17.8
22.2
31.1
44.5
-55°C to +125°C
≤ 85°C:
≤125°C:
≤ 85°C:
≤125°C:
The Important Information/Disclaimer is incorporated in the catalog where these specifications came from or available
online at www.kyocera-avx.com/disclaimer/ by reference and should be reviewed in full before placing any order.
032322
9
–
high reliability tantalum capacitors
–
TAZ SERIES
CWR09 - MIL-PRF-55365/4 Established Reliability,
COTS-Plus & Space Level
Parametric Specifications by Rating per MIL-PRF-55365/4
ESR
DCL max
DF Max
DC Rated
@
+(85/125)
Voltage
+25ºC
+85ºC
+125ºC
+25ºC
100kHz
ºC
V
Ohms
@ +85ºC @ +25ºC
4
4
4
4
4
4
4
4
4
4
6
6
6
6
6
6
6
6
10
10
10
10
10
10
10
10
10
10
10
15
15
15
15
15
15
15
15
20
20
20
20
20
20
20
20
20
45
12
8
8
5.5
4
3.5
2.2
1.1
0.9
8
8
5.5
4.5
3.5
2.2
1.1
0.9
50
50
10
10
8
5.5
4.5
3.5
2.5
1.1
0.9
12
8
5.5
5
4
2.5
1.1
0.9
14
10
12
6
5
4
2.4
1.1
0.9
(μA)
1
1
1
1
1
1
1
2
3
4
1
1
1
1
1
2
3
4
1
1
1
1
1
1
1
1
2
3
5
1
1
1
1
1
2
4
5
1
1
1
1
1
1
2
3
4
(μA)
10
10
10
10
10
10
10
20
30
40
10
10
10
10
10
20
30
40
10
10
10
10
10
10
10
10
20
30
50
10
10
10
10
10
20
40
50
10
10
10
10
10
10
20
30
40
(μA)
12
12
12
12
12
12
12
24
36
48
12
12
12
12
12
24
36
48
12
12
12
12
12
12
12
12
24
36
60
12
12
12
12
12
24
48
60
12
12
12
12
12
12
24
36
48
(%)
6
6
6
6
6
8
8
8
10
10
6
6
6
6
8
8
10
10
6
6
6
6
6
6
6
6
8
10
10
6
6
6
6
6
6
6
8
8
6
6
6
6
6
6
6
6
(%)
8
8
8
8
8
8
10
10
12
12
8
8
8
8
10
10
12
12
8
8
8
8
8
8
8
8
8
12
12
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
Typical RMS Ripple Data by Rating
-55ºC
(%)
8
8
8
8
8
10
12
12
12
12
8
8
8
8
12
12
12
12
8
8
8
8
8
8
8
8
10
12
12
8
8
8
8
8
8
8
10
10
8
8
8
8
8
8
8
8
Power
Dissipation
W
0.030
0.030
0.050
0.070
0.075
0.080
0.090
0.100
0.125
0.150
0.050
0.070
0.075
0.080
0.090
0.100
0.125
0.150
0.030
0.030
0.030
0.050
0.070
0.075
0.080
0.090
0.100
0.125
0.150
0.050
0.070
0.075
0.080
0.090
0.100
0.125
0.150
0.050
0.070
0.070
0.075
0.080
0.090
0.100
0.125
0.150
25ºC
Ripple
A
(100kHz)
0.03
0.05
0.08
0.09
0.12
0.14
0.16
0.21
0.34
0.41
0.08
0.09
0.12
0.13
0.16
0.21
0.34
0.41
0.02
0.02
0.05
0.07
0.09
0.12
0.13
0.16
0.20
0.34
0.41
0.06
0.09
0.12
0.13
0.15
0.20
0.34
0.41
0.06
0.08
0.08
0.11
0.13
0.15
0.20
0.34
0.41
85ºC
Ripple
125ºC
Ripple
25ºC
Ripple
85ºC
Ripple
125ºC
Ripple
RATING & PART NUMBER REFERENCE
CWR09 P/N
MIL & COTS-Plus P/N
TAZ R 334 * 004 C
#
@
0 ^ ++
TAZ R 225 * 004 C
#
@
0 ^ ++
TAZ A 225 * 004 C
#
@
0 ^ ++
TAZ B 475 * 004 C
#
@
0 ^ ++
TAZ C 685 * 004 C
#
@
0 ^ ++
TAZ D 106 * 004 C
#
@
0 ^ ++
TAZ E 156 * 004 C
#
@
0 ^ ++
TAZ F 336 * 004 C
#
@
0 ^ ++
TAZ G 686 * 004 C
#
@
0 ^ ++
TAZ H 107 * 004 C
#
@
0 ^ ++
TAZ A 155 * 006 C
#
@
0 ^ ++
TAZ B 335 * 006 C
#
@
0 ^ ++
TAZ C 475 * 006 C
#
@
0 ^ ++
TAZ D 685 * 006 C
#
@
0 ^ ++
TAZ E 106 * 006 C
#
@
0 ^ ++
TAZ F 226 * 006 C
#
@
0 ^ ++
TAZ G 476 * 006 C
#
@
0 ^ ++
TAZ H 686 * 006 C
#
@
0 ^ ++
TAZ R 334 * 010 C
#
@
0 ^ ++
TAZ R 474 * 010 C
#
@
0 ^ ++
TAZ R 105 * 010 C
#
@
0 ^ ++
TAZ A 105 * 010 C
#
@
0 ^ ++
TAZ B 225 * 010 C
#
@
0 ^ ++
TAZ C 335 * 010 C
#
@
0 ^ ++
TAZ D 475 * 010 C
#
@
0 ^ ++
TAZ E 685 * 010 C
#
@
0 ^ ++
TAZ F 156 * 010 C
#
@
0 ^ ++
TAZ G 336 * 010 C
#
@
0 ^ ++
TAZ H 476 * 010 C
#
@
0 ^ ++
TAZ A 684 * 015 C
#
@
0 ^ ++
TAZ B 155 * 015 C
#
@
0 ^ ++
TAZ C 225 * 015 C
#
@
0 ^ ++
TAZ D 335 * 015 C
#
@
0 ^ ++
TAZ E 475 * 015 C
#
@
0 ^ ++
TAZ F 106 * 015 C
#
@
0 ^ ++
TAZ G 226 * 015 C
#
@
0 ^ ++
TAZ H 336 * 015 C
#
@
0 ^ ++
TAZ A 474 * 020 C
#
@
0 ^ ++
TAZ B 684 * 020 C
#
@
0 ^ ++
TAZ B 105 * 020 C
#
@
0 ^ ++
TAZ C 155 * 020 C
#
@
0 ^ ++
TAZ D 225 * 020 C
#
@
0 ^ ++
TAZ E 335 * 020 C
#
@
0 ^ ++
TAZ F 685 * 020 C
#
@
0 ^ ++
TAZ G 156 * 020 C
#
@
0 ^ ++
TAZ H 226 * 020 C
#
@
0 ^ ++
SRC9000 P/N
Case
R
R
A
B
C
D
E
F
G
H
A
B
C
D
E
F
G
H
R
R
R
A
B
C
D
E
F
G
H
A
B
C
D
E
F
G
H
A
B
B
C
D
E
F
G
H
Cap
@ 120Hz
μF
@ 25ºC
0.33
2.2
2.2
4.7
6.8
10
15
33
68
100
1.5
3.3
4.7
6.8
10
22
47
68
0.33
0.47
1
1
2.2
3.3
4.7
6.8
15
33
47
0.68
1.5
2.2
3.3
4.7
10
22
33
0.47
0.68
1
1.5
2.2
3.3
6.8
15
22
A
A
V
V
V
(100kHz) (100kHz) (100kHz) (100kHz) (100kHz)
0.02
0.05
0.07
0.08
0.11
0.13
0.14
0.19
0.30
0.37
0.07
0.08
0.11
0.12
0.14
0.19
0.30
0.37
0.02
0.02
0.05
0.06
0.08
0.11
0.12
0.14
0.18
0.30
0.37
0.06
0.08
0.11
0.11
0.14
0.18
0.30
0.37
0.05
0.08
0.07
0.10
0.11
0.14
0.18
0.30
0.37
0.01
0.02
0.03
0.04
0.05
0.06
0.06
0.09
0.13
0.16
0.03
0.04
0.05
0.05
0.06
0.09
0.13
0.16
0.01
0.01
0.02
0.03
0.04
0.05
0.05
0.06
0.08
0.13
0.16
0.03
0.04
0.05
0.05
0.06
0.08
0.13
0.16
0.02
0.03
0.03
0.04
0.05
0.06
0.08
0.13
0.16
1.16
0.60
0.63
0.75
0.64
0.57
0.56
0.47
0.37
0.37
0.63
0.75
0.64
0.60
0.56
0.47
0.37
0.37
1.22
1.22
0.55
0.71
0.75
0.64
0.60
0.56
0.50
0.37
0.37
0.77
0.75
0.64
0.63
0.60
0.50
0.37
0.37
0.84
0.84
0.92
0.67
0.63
0.60
0.49
0.37
0.37
1.05
0.54
0.57
0.67
0.58
0.51
0.51
0.42
0.33
0.33
0.57
0.67
0.58
0.54
0.51
0.42
0.33
0.33
1.10
1.10
0.49
0.64
0.67
0.58
0.54
0.51
0.45
0.33
0.33
0.70
0.67
0.58
0.57
0.54
0.45
0.33
0.33
0.75
0.75
0.82
0.60
0.57
0.54
0.44
0.33
0.33
0.46
0.24
0.25
0.30
0.26
0.23
0.22
0.19
0.15
0.15
0.25
0.30
0.26
0.24
0.22
0.19
0.15
0.15
0.49
0.49
0.22
0.28
0.30
0.26
0.24
0.22
0.20
0.15
0.15
0.31
0.30
0.26
0.25
0.24
0.20
0.15
0.15
0.33
0.33
0.37
0.27
0.25
0.24
0.20
0.15
0.15
CWR09C^225*@+
CWR09C^475*@+
CWR09C^685*@+
CWR09C^106*@+
CWR09C^156*@+
CWR09C^336*@+
CWR09C^686*@+
CWR09C^107*@+
CWR09D^155*@+
CWR09D^335*@+
CWR09D^475*@+
CWR09D^685*@+
CWR09D^106*@+
CWR09D^226*@+
CWR09D^476*@+
CWR09D^686*@+
TAZ A 225 * 004 C
L
@
9 ^ ++
TAZ B 475 * 004 C
L
@
9 ^ ++
TAZ C 685 * 004 C
L
@
9 ^ ++
TAZ D 106 * 004 C
L
@
9 ^ ++
TAZ E 156 * 004 C
L
@
9 ^ ++
TAZ F 336 * 004 C
L
@
9 ^ ++
TAZ G 686 * 004 C
L
@
9 ^ ++
TAZ H 107 * 004 C
L
@
9 ^ ++
TAZ A 155 * 006 C
L
@
9 ^ ++
TAZ B 335 * 006 C
L
@
9 ^ ++
TAZ C 475 * 006 C
L
@
9 ^ ++
TAZ D 685 * 006 C
L
@
9 ^ ++
TAZ E 106 * 006 C
L
@
9 ^ ++
TAZ F 226 * 006 C
L
@
9 ^ ++
TAZ G 476 * 006 C
L
@
9 ^ ++
TAZ H 686 * 006 C
L
@
9 ^ ++
CWR09F^105*@+
CWR09F^225*@+
CWR09F^335*@+
CWR09F^475*@+
CWR09F^685*@+
CWR09F^156*@+
CWR09F^336*@+
CWR09F^476*@+
CWR09H^684*@+
CWR09H^155*@+
CWR09H^225*@+
CWR09H^335*@+
CWR09H^475*@+
CWR09H^106*@+
CWR09H^226*@+
CWR09H^336*@+
CWR09J^474*@+
CWR09J^684*@+
CWR09J^105*@+
CWR09J^155*@+
CWR09J^225*@+
CWR09J^335*@+
CWR09J^685*@+
CWR09J^156*@+
CWR09J^226*@+
TAZ A 105 * 010 C
L
@
9 ^ ++
TAZ B 225 * 010 C
L
@
9 ^ ++
TAZ C 335 * 010 C
L
@
9 ^ ++
TAZ D 475 * 010 C
L
@
9 ^ ++
TAZ E 685 * 010 C
L
@
9 ^ ++
TAZ F 156 * 010 C
L
@
9 ^ ++
TAZ G 336 * 010 C
L
@
9 ^ ++
TAZ H 476 * 010 C
L
@
9 ^ ++
TAZ A 684 * 015 C
L
@
9 ^ ++
TAZ B 155 * 015 C
L
@
9 ^ ++
TAZ C 225 * 015 C
L
@
9 ^ ++
TAZ D 335 * 015 C
L
@
9 ^ ++
TAZ E 475 * 015 C
L
@
9 ^ ++
TAZ F 106 * 015 C
L
@
9 ^ ++
TAZ G 226 * 015 C
L
@
9 ^ ++
TAZ H 336 * 015 C
L
@
9 ^ ++
TAZ A 474 * 020 C
L
@
9 ^ ++
TAZ B 684 * 020 C
L
@
9 ^ ++
TAZ B 105 * 020 C
L
@
9 ^ ++
TAZ C 155 * 020 C
L
@
9 ^ ++
TAZ D 225 * 020 C
L
@
9 ^ ++
TAZ E 335 * 020 C
L
@
9 ^ ++
TAZ F 685 * 020 C
L
@
9 ^ ++
TAZ G 156 * 020 C
L
@
9 ^ ++
TAZ H 226 * 020 C
L
@
9 ^ ++
All technical data relates to an ambient temperature of +25°C. Capacitance and DF are measured at 120Hz, 0.5V RMS with a maximum DC bias of 2.2 volts. DCL is measured at rated voltage after 5 minutes.
NOTE: KYOCERA AVX reserves the right to supply a higher voltage rating or tighter tolerance part in the same case size, to the same reliability standards.
10
The Important Information/Disclaimer is incorporated in the catalog where these specifications came from or available
online at www.kyocera-avx.com/disclaimer/ by reference and should be reviewed in full before placing any order.
062620
–
high reliability tantalum capacitors
–
TAZ SERIES
CWR09 - MIL-PRF-55365/4 Established Reliability,
COTS-Plus & Space Level
RATING & PART NUMBER REFERENCE
CWR09 P/N
CWR09K^334*@+
CWR09K^684*@+
CWR09K^105*@+
CWR09K^155*@+
CWR09K^225*@+
CWR09K^475*@+
CWR09K^685*@+
CWR09K^106*@+
CWR09K^156*@+
CWR09M^224*@+
CWR09M^474*@+
CWR09M^684*@+
CWR09M^105*@+
CWR09M^155*@+
CWR09M^335*@+
CWR09M^475*@+
CWR09M^685*@+
CWR09N^104*@+
CWR09N^154*@+
CWR09N^224*@+
CWR09N^334*@+
CWR09N^474*@+
CWR09N^684*@+
CWR09N^105*@+
CWR09N^155*@+
CWR09N^225*@+
CWR09N^335*@+
CWR09N^475*@+
MIL & COTS-Plus P/N
TAZ A 334 * 025 C
#
@
0 ^ ++
TAZ B 684 * 025 C
#
@
0 ^ ++
TAZ C 105 * 025 C
#
@
0 ^ ++
TAZ D 155 * 025 C
#
@
0 ^ ++
TAZ E 225 * 025 C
#
@
0 ^ ++
TAZ F 475 * 025 C
#
@
0 ^ ++
TAZ G 685 * 025 C
#
@
0 ^ ++
TAZ G 106 * 025 C
#
@
0 ^ ++
TAZ H 156 * 025 C
#
@
0 ^ ++
TAZ A 224 * 035 C #
@
0 ^ ++
TAZ B 474 * 035 C #
@
0 ^ ++
TAZ C 684 * 035 C #
@
0 ^ ++
TAZ D 105 * 035 C #
@
0 ^ ++
TAZ E 155 * 035 C #
@
0 ^ ++
TAZ F 335 * 035 C #
@
0 ^ ++
TAZ G 475 * 035 C #
@
0 ^ ++
TAZ H 685 * 035 C #
@
0 ^ ++
TAZ A 104 * 050 C #
@
0 ^ ++
TAZ A 154 * 050 C #
@
0 ^ ++
TAZ B 224 * 050 C #
@
0 ^ ++
TAZ B 334 * 050 C #
@
0 ^ ++
TAZ C 474 * 050 C #
@
0 ^ ++
TAZ D 684 * 050 C #
@
0 ^ ++
TAZ E 105 * 050 C #
@
0 ^ ++
TAZ F 155 * 050 C #
@
0 ^ ++
TAZ F 225 * 050 C #
@
0 ^ ++
TAZ G 335 * 050 C #
@
0 ^ ++
TAZ H 475 * 050 C #
@
0 ^ ++
SRC9000 P/N
TAZ A 334 * 025 C
L
@
9 ^ ++
TAZ B 684 * 025 C
L
@
9 ^ ++
TAZ C 105 * 025 C
L
@
9 ^ ++
TAZ D 155 * 025 C
L
@
9 ^ ++
TAZ E 225 * 025 C
L
@
9 ^ ++
TAZ F 475 * 025 C
L
@
9 ^ ++
TAZ G 685 * 025 C
L
@
9 ^ ++
TAZ G 106 * 025 C
L
@
9 ^ ++
TAZ H 156 * 025 C
L
@
9 ^ ++
TAZ A 224 * 035 C L
@
9 ^ ++
TAZ B 474 * 035 C L
@
9 ^ ++
TAZ C 684 * 035 C L
@
9 ^ ++
TAZ D 105 * 035 C L
@
9 ^ ++
TAZ E 155 * 035 C L
@
9 ^ ++
TAZ F 335 * 035 C L
@
9 ^ ++
TAZ G 475 * 035 C L
@
9 ^ ++
TAZ H 685 * 035 C L
@
9 ^ ++
TAZ A 104 * 050 C L
@
9 ^ ++
TAZ A 154 * 050 C L
@
9 ^ ++
TAZ B 224 * 050 C L
@
9 ^ ++
TAZ B 334 * 050 C L
@
9 ^ ++
TAZ C 474 * 050 C L
@
9 ^ ++
TAZ D 684 * 050 C L
@
9 ^ ++
TAZ E 105 * 050 C L
@
9 ^ ++
TAZ F 155 * 050 C L
@
9 ^ ++
TAZ F 225 * 050 C L
@
9 ^ ++
TAZ G 335 * 050 C L
@
9 ^ ++
TAZ H 475 * 050 C L
@
9 ^ ++
Case
A
B
C
D
E
F
G
G
H
A
B
C
D
E
F
G
H
A
A
B
B
C
D
E
F
F
G
H
Cap
@ 120Hz
μF
@ 25ºC
0.33
0.68
1
1.5
2.2
4.7
6.8
10
15
0.22
0.47
0.68
1
1.5
3.3
4.7
6.8
0.1
0.15
0.22
0.33
0.47
0.68
1
1.5
2.2
3.3
4.7
Parametric Specifications by Rating per MIL-PRF-55365/4
ESR
DCL max
DF Max
DC Rated
@
+(85/125)
Voltage
+25ºC
+85ºC
+125ºC
+25ºC
100kHz
ºC
V
Ohms
@ +85ºC @ +25ºC
25
25
25
25
25
25
25
25
25
35
35
35
35
35
35
35
35
50
50
50
50
50
50
50
50
50
50
50
15
7.5
6.5
6.5
3.5
2.5
1.2
1.4
1
18
10
8
6.5
4.5
2.5
1.5
1.3
22
17
14
12
8
7
6
4
2.5
2
1.5
(μA)
1
1
1
1
1
2
2
3
4
1
1
1
1
1
1
2
3
1
1
1
1
1
1
1
1
2
2
3
(μA)
10
10
10
10
10
20
20
30
40
10
10
10
10
10
10
20
30
10
10
10
10
10
10
10
10
20
20
30
(μA)
12
12
12
12
12
24
24
36
48
12
12
12
12
12
12
24
36
12
12
12
12
12
12
12
12
24
24
36
(%)
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
(%)
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
Typical RMS Ripple Data by Rating
-55ºC
(%)
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
Power
Dissipation
W
0.050
0.070
0.075
0.080
0.090
0.100
0.125
0.125
0.150
0.050
0.070
0.075
0.080
0.090
0.100
0.125
0.150
0.050
0.050
0.070
0.070
0.075
0.080
0.090
0.100
0.100
0.125
0.150
25ºC
Ripple
A
(100kHz)
0.06
0.10
0.11
0.11
0.16
0.20
0.32
0.30
0.39
0.05
0.08
0.10
0.11
0.14
0.20
0.29
0.34
0.05
0.05
0.07
0.08
0.10
0.11
0.12
0.16
0.20
0.25
0.32
85ºC
Ripple
125ºC
Ripple
25ºC
Ripple
85ºC
Ripple
125ºC
Ripple
A
A
V
V
V
(100kHz) (100kHz) (100kHz) (100kHz) (100kHz)
0.05
0.09
0.10
0.10
0.14
0.18
0.29
0.27
0.35
0.05
0.08
0.09
0.10
0.13
0.18
0.26
0.31
0.04
0.05
0.06
0.07
0.09
0.10
0.11
0.14
0.18
0.23
0.28
0.02
0.04
0.04
0.04
0.06
0.08
0.13
0.12
0.15
0.02
0.03
0.04
0.04
0.06
0.08
0.12
0.14
0.02
0.02
0.03
0.03
0.04
0.04
0.05
0.06
0.08
0.10
0.13
0.87
0.72
0.70
0.72
0.56
0.50
0.39
0.42
0.39
0.95
0.84
0.77
0.72
0.64
0.50
0.43
0.44
1.05
0.92
0.99
0.92
0.77
0.75
0.73
0.63
0.50
0.50
0.47
0.78
0.65
0.63
0.65
0.51
0.45
0.35
0.38
0.35
0.85
0.75
0.70
0.65
0.57
0.45
0.39
0.40
0.94
0.83
0.89
0.82
0.70
0.67
0.66
0.57
0.45
0.45
0.43
0.35
0.29
0.28
0.29
0.22
0.20
0.15
0.17
0.15
0.38
0.33
0.31
0.29
0.25
0.20
0.17
0.18
0.42
0.37
0.40
0.37
0.31
0.30
0.29
0.25
0.20
0.20
0.19
All technical data relates to an ambient temperature of +25°C. Capacitance and DF are measured at 120Hz, 0.5V RMS with a maximum DC bias of 2.2 volts. DCL is measured at rated voltage after 5 minutes.
NOTE: KYOCERA AVX reserves the right to supply a higher voltage rating or tighter tolerance part in the same case size, to the same reliability standards.
The Important Information/Disclaimer is incorporated in the catalog where these specifications came from or available
online at www.kyocera-avx.com/disclaimer/ by reference and should be reviewed in full before placing any order.
062620
11
–
high reliability tantalum capacitors
–
TAZ SERIES
CWR19 - MIL-PRF-55365/11 Established Reliability,
COTS-Plus & Space Level
An extended range of capacitor ratings beyond
CWR09 that is fully qualified to MIL-PRF-55365/11,
this series represents the most flexible of surface
mount form factors, offering nine case sizes (the
original A through H of CWR09) and adds the new
X case size.
The molded body / compliant termination
construction ensures no TCE mismatch with any
substrate. This construction is compatible with
a wide range of SMT board assembly processes
including convection reflow solder, conductive epoxy
or compression bonding techniques. The parts also
carry full polarity and capacitance / voltage marking.
The four smaller cases are characterized by their low
profile construction, with the A case being the world’s
smallest molded military tantalum chip.
The series is qualified to MIL-PRF-55365 Weibull
“B”, “C”, “D” and “T” levels, with all surge options
(“A”, “B” & “C”) available.
For Space Level applications, SRC 9000
qualification is recommended (see ratings table
for part number availability).
There are four termination finishes available:
solder plated, fused solder plated, hot solder
dipped and gold plated (these are “H”, “K”, “C” and
“B” termination, respectively, per MIL-PRF-55365).
In addition, the molding compound has been
selected to meet the requirements of UL94V-0
(Flame Retardancy) and outgassing requirements
of ASTM E-595.
For moisture sensitivity levels please refer to the High
Reliability Tantalum MSL section located in the back
of the High Reliability Tantalum Catalog.
CASE DIMENSIONS:
Case
Code
Length (L)
±0.38
(0.015)
Width (W)
±0.38
(0.015)
Height (H)
±0.38
(0.015)
Term. Width
(W
1
)
1.27±0.13
(0.050±0.005)
1.27±0.13
(0.050±0.005)
1.27±0.13
(0.050±0.005)
2.41+0.13/-0.25
(0.095+0.005/-0.010)
2.41+0.13/-0.25
(0.095+0.005/-0.010)
3.30±0.13
(0.130±0.005)
2.67±0.13
(0.105±0.005)
3.68+0.13/-0.51
(0.145+0.005/-0.020)
3.05±0.13
(0.120±0.005)
millimeters (inches)
Term. Length (A)
+0.25/-0.13
(+0.010/-0.005)
0.76 (0.030)
0.76 (0.030)
0.76 (0.030)
0.76 (0.030)
0.76 (0.030)
0.76 (0.030)
1.27 (0.050)
1.27 (0.050)
1.19 (0.047)
S min
0.38 (0.015)
1.65 (0.065)
2.92 (0.115)
1.65 (0.065)
2.92 (0.115)
3.43 (0.135)
3.56 (0.140)
4.06 (0.160)
3.67 (0.144)
Typical
Weight (g)
0.016
0.025
0.035
0.045
0.065
0.125
0.205
0.335
0.420
MARKING
(White marking on black body)
Polarity Stripe (+)
Capacitance Code
Rated Voltage
A
B
C
D
E
F
G
H
X
2.54 (0.100) 1.27 (0.050) 1.27 (0.050)
3.81 (0.150) 1.27 (0.050) 1.27 (0.050)
5.08 (0.200) 1.27 (0.050) 1.27 (0.050)
3.81 (0.150) 2.54 (0.100) 1.27 (0.050)
5.08 (0.200) 2.54 (0.100) 1.27 (0.050)
5.59 (0.220) 3.43 (0.135) 1.78 (0.070)
6.73 (0.265) 2.79 (0.110)
7.24 (0.285) 3.81 (0.150)
6.93 (0.273) 5.41 (0.213)
2.79 (0.110)
2.79 (0.110)
2.74 (0.108)
CWR19-MIL-PRF 55365/11
CAPACITANCE AND RATED VOLTAGE, V
R
(VOLTAGE CODE) RANGE (LETTER DENOTES CASE SIZE)
Capacitance
µF
0.33
0.47
0.68
1.0
1.5
2.2
3.3
4.7
6.8
10
15
22
33
47
68
100
150
220
330
Code
334
474
684
105
155
225
335
475
685
106
156
226
336
476
686
107
157
227
337
4V (C)
6V (D)
Rated Voltage DC (V
R
) at 85ºC
10V (F)
15V (H)
20V (J)
25V (K)
A
B
D
E
F
G
G/H
H/X
G
H
X
35V (M)
A
A
A
A
B
B
B/D
D/E
E
E
F
G
H
H
A
A
B
B
B/D/E
D/E
E
F
F/G
G
G
H
H
A
A
B/C
B/C/D
B/C/D/E
D/E
E
F
F/G
G
G/H
H/X
H
A
A
A
B
B/C/D
D/E
D/E
E/F
F
F/G
G/H
G/H
H
A
A
B
B
D
E
E
E/F
F
G
H
H/X
12
The Important Information/Disclaimer is incorporated in the catalog where these specifications came from or available
online at www.kyocera-avx.com/disclaimer/ by reference and should be reviewed in full before placing any order.
The temperature is measured by thermocouple, PID is adjusted by single chip microcomputer, and the solid state relay is triggered to realize linear temperature rise. However, when the grid voltage cha...
[img]http://www.dzdiy.com/uppic/31929102007211857_1.gif[/img] There are many designs that use infrared remote control as switch control. You can find some good designs on the Internet. However, to rea...
Competition schedule: From now on to December 21st Competition entrance: https://www.eeworld.com.cn/huodong/201508_STM32F746/index.html https://www.eeworld.com.cn/huodong/201508_STM32F746/index.html P...
Although the score is small, it is more than half of my own score. Sorry, let me explain the content of the question in detail: The core is to burn the mp3 file into the off-chip NOR flash of the arm7...
[i=s]This post was last edited by dontium on 2015-1-23 11:28[/i]Linear power supply technology is very mature and can achieve high stability and small ripples. It can achieve high-precision and low-ri...
Assume that data is read from 8-bit AD (if it is a higher-bit AD, the data type can be defined as int), the subroutine is get_ad();
1. Limited secondary filtering
/* A value can be adjust...[Details]
introduction
With the continuous optimization of surface mount technology (SMT) and the rapid development of chip component manufacturing technology, the application of chip mounters in the el...[Details]
1. Introduction
Automobile pollution is one of the most important issues that people are most concerned about and need to solve urgently. As an important method for detecting automobile exhau...[Details]
Floating-point digital signal processing has become a constant requirement for precision technology, often in applications requiring high accuracy in areas such as aviation, industrial machinery, a...[Details]
The Portable Digital Data Acquisition System (PDDAS) uses LabVIEW Real-Time and PXI to control the wind tunnel test and record air pressure data from 128 different channels.
"The LabVIEW Real-...[Details]
1 Introduction
Solar street lights are mainly composed of four parts: solar photovoltaic cell components, batteries, charge and discharge controllers, and lighting fixtures. The bo...[Details]
My colleague and I spent the day chatting in the hotel bar. We had met with several customers. We were both wondering how come these engineers we were meeting knew almost nothing about analog techn...[Details]
introduction
The emergence of high-performance, low-power embedded CPUs and high-reliability network operating systems has made it possible to implement applications with large amounts of comp...[Details]
1 Introduction
Water resources are the basic conditions for human survival and the lifeline of economic development. The reality shows that due to the global shortage of water resources and th...[Details]
In the analysis of electronic circuits, static analysis (also known as DC analysis) is the basis of circuit analysis. However, it is well known that electronic components are nonlinear, so the anal...[Details]
RS-422 and RS-485 are both serial data interface standards, which were developed and published by the Electronic Industries Association (EIA). RS-422 defines a balanced communication interface with a ...[Details]
Overview
In spectral measurement, photomultiplier tubes (PMT) and charge-coupled devices (CCD) are often used as photoelectric converters. PMT is used in slow-changing, high-precision spectral...[Details]
Describe how to meet the challenges of complexity with a modern wiring design toolset. Option codes and expressions can simulate the variables of an automotive project. A full-featured tool suite c...[Details]
1 Introduction to LED
With the development of science and technology, people have higher and higher requirements on automobile light sources. LED (Light Emitting Diode) has gradually attracted...[Details]
This article discusses the six design steps of LED lighting system design in detail: (1) determine the lighting requirements; (2) determine the design goals and estimate the optics; (3) the efficie...[Details]