Moisture Sensitivity Level (MSL) – This product is Hermetically Sealed and not Moisture
Sensitive - MSL = N/A: Not Applicable
Pb
RoHS
Compliant
3.2 x 2.5 x 0.8mm
FEATURES:
• Seam sealed package assures high reliability
• Tight tolerance and stability available
• Suitable for RoHS reflow
APPLICATIONS:
• High density applications
• Modems, communication and test equipment
• PMCIA, Wireless applications
STANDARD SPECIFICATIONS:
Parameters
Frequency Range
Operation Mode
Operating Temperature
Storage Temperature
Frequency Tolerance @+25°C
Frequency Stability over the Operating
Temperature ( ref. to +25°C)
Equivalent series resistance (R1)
Shunt capacitance (C0)
Load capacitance (CL)
Drive Level
Aging
Insulation Resistance
TABLE 1- Standard ESR
Frequency (MHz)
10.000 -11.999 (Fund)
12.000 -15.999 (Fund)
16.000 -19.999 (Fund)
20.000 - 29.999 (Fund)
-2
500
ESR( )
max
200
120
70
50
Minimum
10.000
Typical
Maximum
125.000*
Units
MHz
Notes
Contact Abracon for
available F<10MHz
10MHz - 54MHz
64MHz - 125MHz
Please contact Abracon for
available frequencies
Fundamental
3rd Overtone
(Standard Frequencies: 64, 66, 66.6666, 75,
80, 98.304, 100, 125MHz)
-10
+60
-55
+125
-50
+50
-50
See table 1 below
3.0
18.0
10
100
+2
+50
ºC
ºC
ppm
ppm
pF
pF
µW
ppm
M
(see options if other than STD)
Standard
Standard
Standard
(see options if other than STD)
(see options if other than STD)
Standard
(See options if
other than STD)
@25°C±3°C
First year
@ 100Vdc ± 15V
ESR( )
max
40
35
120
80
Frequency (MHz)
30.000 - 39.999 (Fund)
40.000 - 54.000 (Fund)
64.000 - 80.000 (3rd OT)
98.304 - 125.000 (3rd OT)
OPTIONS AND PART IDENTIFICATION: (Left blank if standard)
ABM8
Height (mm)
Blank: 0.80 max
1: 0.65±0.05
2: 0.60±0.10
Frequency in MHz
Please specify the
frequency in MHz.
e.g. 16.000MHz
Load Capacitance (pF)
Please specify CL (min
6pF) in pF or S for series
Custom ESR if
other than standard
R
: Specify a value in
(e.g.: R40)
Operating Temp.
E
Blank: -10°C ~ +60°C
E: 0°C ~ +70°C
B: -20°C ~ +70°C
C: -30°C ~ +70°C
N: -30°C ~ +85°C
D: -40°C ~ +85°C
J**: -40°C ~ +105°C
K**: -40°C ~ +125°C
** Frequency stability ±
50ppm and ± 100 ppm
-
MHz -
-
-
-
Packaging
Blank: Bulk
T: 1kpcs / reel
T2: 250pcs / reel
T3: 3kpcs / reel
Freq. Stability
Blank: ± 50 ppm
U: ± 10 ppm(*)
G: ± 15 ppm
X: ± 20 ppm
W: ± 25 ppm
Y: ± 30 ppm
H: ± 35 ppm
Q: ± 100 ppm
(*) Option E, B, and
-10°C to +60°C only.
Freq. Tolerance
Blank: ± 50 ppm
1: ± 10 ppm
7: ± 15 ppm
2: ± 20 ppm
3: ± 25 ppm
4: ± 30 ppm
LLC
5101 Hidden Creek Ln Spicewood TX 78669
Phone: 512-371-6159 | Fax: 512-351-8858
For terms and conditions of sales, please visit:
www.abracon.com
ABRACON IS
REVISED: 07-1-20
ISO9001-2015
CERTIFIED
CERAMIC SMD CRYSTAL
ABM8
OUTLINE DRAWING:
Pb
RoHS
Compliant
3.2 x 2.5 x 0.8mm
Note:
Due to material availability, the chamfer could be located
on pin #1, 3, or 4. Be advised that the chamfer location has
no impact on the electrical performance of the device.
Table 2
Height (mm)
ABM8
0.80 max
ABM81
0.65+/-0.05
ABM82
0.60+/-0.10
Dimensions: mm
TAPE & REEL:
Option "-T"
: Tape and reel (1,000pcs/reel) : ABM8, ABM82
Tape and reel (3,000pcs/reel) : ABM81
Option "-T2" : Tape and reel (250pcspcs/reel) : ABM8
Option "-T3" : Tape and reel (3,000pcs/reel) : ABM8, ABM82 only
REFLOW PROFILE:
Zone
1
2
3
Dimensions: mm
Description
Temperature
Time
Preheat
Reflow
Peak heat
T
SMIN
~ T
SMAX
150°C ~ 180°C
T
L
230°C
T
P
260°C
±
5°C
60 ~ 120 sec.
30 ~ 40 sec.
10 sec. MAX
ATTENTION:
Abracon LLC’s products are COTS – Commercial-O -The-Shelf products; suitable for Commercial, Industrial and, where designated, Automotive Applica-
tions. Abracon’s products are not specifically designed for Military, Aviation, Aerospace, Life-dependent Medical applications or any application requiring high reliability
where component failure could result in loss of life and/or property. For applications requiring high reliability and/or presenting an extreme operating environment,
written consent and authorization from Abracon LLC is required. Please contact Abracon LLC for more information.
[i=s]This post was last edited by paulhyde on 2014-9-15 09:05[/i] This is the complete English information of AD602, which may be useful in question C....
I can't read the meter data. The source code is as follows: Please give me some advice. Thank you very much. I am a newbie and don't know where to check my points. If the problem is solved, I will get...
I want to save data (3 bytes) to EEPROM when power is off, and use BOD power-off detection, but I don't know how to use it. I hope experts can give me some advice:1. After setting BODEN and BODLEVEL i...
[i=s]This post was last edited by eagler8 on 2021-10-5 19:26[/i]For this project, four specifications of OLED organic screens were specially prepared....
[align=left][color=#444444][font=微软雅黑][size=9.0pt]I was so stuck in the hard data work.[/size][/font][/color][/align] [align=left][color=#444444][font=微软雅黑][size=9.0pt]I tried to make a small prototyp...
Designers use PSpice primarily to simulate analog circuits. However, it can also be used to simulate digital filters. The main components in a digital filter are delay elements, adders, and multipl...[Details]
Medicines are special commodities. If patients are given the wrong medicine, fake medicine, inferior medicine or expired medicine, it will pose a threat to people's health and lives.
In recent...[Details]
introduction
Oxygen is an important substance for human metabolism. Brain tissue has a high metabolic rate and consumes about 20% of the total oxygen in the body. In the clinical rescue and ...[Details]
With the advancement of computer technology, the development of image processing and pattern recognition methods, fingerprint processing technology has become more mature and has been widely used i...[Details]
At present, the global medical electronics industry is gradually showing attractive development prospects, and the speed of product replacement is constantly increasing. At the same time, due to the p...[Details]
The particularity of portable medical devices determines that they should be user-friendly, must work in a sterile environment, and occupy little space and consume low energy.
At the same time, por...[Details]
Many medical applications require portable, self-powered devices that do not require external power and data cables. The most obvious example is a portable data logger that patients carry with them to...[Details]
Due to the needs of medical development, in many cases, general thermometers can no longer meet the requirements of fast and accurate temperature measurement, such as measuring human body temperature ...[Details]
introduction
The data detected by various measuring instruments often need to be transferred to the PC for data processing and archiving, so as to make full use of the rich hardware and softwa...[Details]
MOSFETs are widely used as power switching elements in regulators and motor controllers. They are available as discrete devices or integrated into ICs in various H-bridge configurations.
A hig...[Details]
Preface
In recent years, many compact portable electronic products have been developed, such as mobile phones, digital cameras, MP3, MP4, PDA, GPS and DVD, etc. They are not only small in size...[Details]
In the issue of ensuring the safety of drivers and pedestrians, the proportion of electronic technology has increased. According to the survey, 80% to 90% of traffic accidents are caused by driver...[Details]
1 Introduction
Reliability research originated from weapon systems. After nearly half a century of development, it has become an engineering discipline that covers all disciplines and industri...[Details]
Introduction: Generally speaking, the power supplies used to drive today's high-resolution analog/digital converters have AC or DC loads of hundreds of ohms or more. Therefore, an operational ampli...[Details]
With the advent of the new economic era represented by the Internet, PCs have lost their former glory, and smart 3C products (Computer, Communication and Consumer) will set off a new wave. As one o...[Details]