EEWORLDEEWORLDEEWORLD

Part Number

Search

LCS052S26WB30EW

Description
SNAP ACTING/LIMIT SWITCH, SPST, MOMENTARY, 5.6mm, PANEL MOUNT, ROHS COMPLIANT
CategoryMechanical and electronic products    switch   
File Size326KB,4 Pages
ManufacturerC&K Components
Environmental Compliance  
Download Datasheet Parametric View All

LCS052S26WB30EW Overview

SNAP ACTING/LIMIT SWITCH, SPST, MOMENTARY, 5.6mm, PANEL MOUNT, ROHS COMPLIANT

LCS052S26WB30EW Parametric

Parameter NameAttribute value
Is it lead-free?Lead free
Is it Rohs certified?conform to
Objectid1084425213
package instructionROHS COMPLIANT
Reach Compliance Codecompliant
Country Of OriginMainland China
ECCN codeEAR99
YTEOL8.2
Actuator stroke5.6 mm
Actuator typeSIMULATED LEVER
body width6.4 mm
body height9.8 mm
Body length or diameter19.8 mm
Contact (AC) maximum rated R load5A@250VAC
Maximum contact current (AC)5 A
Maximum contact voltage (AC)250 V
Electrical life10000 Cycle(s)
Installation featuresPANEL MOUNT
Maximum operating force1.99 N
Maximum operating temperature120 °C
Minimum operating temperature
Maximum pre-travel4.6 mm
sealIP67
surface mountNO
Switch actionMOMENTARY
switch functionSPST
Switch typeSNAP ACTING/LIMIT SWITCH
Termination typeWIRE
LCS Series
Subminiature Sealed Snap-acting Switches
Features/Benefits
Compact design
Long life and high electrical capacity
Quick connect, solder terminals,
PC terminals, wire leads
Wide variety of actuator styles
RoHS compatible, RoHS compliant
IP67
Specifications
CONTACT RATING: 6 AMP, 250 V AC and
5 AMP, 125/250 V AC
0.1 AMP, 125/250 V AC
ELECTRICAL LIFE: 10,000 cycles
INSULATION RESISTANCE: 100 M ohm min.
DIELECTRIC STRENGTH: 1,000 VAC
OPERATING TEMPERATURE:
-40ºC to +120ºC (without wire)
-40ºC to +85ºC (with UL1007 wire)
-40ºC to +105ºC (with UL1015 wire)
-40ºC to +105ºC (with UL1430 wire)
-40ºC to +80ºC (with UL1061 wire)
-40ºC to +120ºC (with UL1330 wire)
OPERATING FORCE: (see ACTUATOR’S option sections).
MOUNTING: 2-56 screws, torque 2.3 in/lbs max.
NOTE:
Specifications and materials listed above are for switches with standard options.
For information on specific and custom switches, consult Customer Service center.
14
Typical Applications
Motorized equipment
Sump pump
Thermostatic controls
Computers
Air conditioners
14
Materials
SWITCH HOUSING: Thermoplastic polyester or high temperature
thermoplastic (PTS) (UL 94V-0).
ACTUATOR BUTTON: Thermoplastic polyester.
SPRING: Copper alloy.
PIVOT: Copper alloy.
MOVABLE CONTACTS: Silver nickel
STATIONARY CONTACTS: Silver nickel on copper alloy.
TERMINALS: Copper alloy.
ACTUATOR LEVEL: Stainless steel.
J
Snap-acting
Build-A-Switch
To order, simply select desired option from each category and place in the appropriate box. Available options are shown and
described on pages J-27 thru J-29. For additional options not shown in catalog, consult Customer Service Center.
L
Series
LCS
Contact Rating
05
5 AMP, 125/250 V AC
6 AMP, 250 V AC
01
0.1 AMP, 125/250 V AC
C
S
14
Operating Force
1
150 grams
2
203 grams
Actuator
P00
Pin plunger
T00
11.9 mm short lever
T05
17.4 mm short lever
T07
19.4 mm short lever
T13
25.5 mm lever
T19
33.3 mm lever
T28
40.7 mm lever
T43
55.9 mm lever
S26
18.6 mm simulated lever
A05
17.2 mm lever roller
Circuitry
C
SPDT
W
SPST N.C.
Y
SPST N.O.
Wire Type AWG
20
20 AWG
22
22 AWG
24
24 AWG
26
26 AWG
28
28 AWG
30
30 AWG
Wire UL #
(when required)
A
UL1007
B
UL1015
C
UL1430
D
UL1061
E
UL1330
Terminations
S
Solder
Q
0.110 Quick Connect
P
PC Thru Hole
W
Wire leads potted
Z
Wire leads non-potted
Wire Side (when required)
A
Wire out the bottom
B
Wire out the right side
C
Wire out the left side
D
None
Dimensions are shown: mm
Specifications and dimensions subject to change
J–26
www.ck-components.com
【LINK NODE final】Link node evaluation completed, the board can be recycled
Regarding LINK NODE, although I followed Johnrey's method and found some problems with the content of sending and receiving, the Bluetooth was working. To me, this seemed to just verify that under mbe...
辛昕 RF/Wirelessly
A Trigger Circuit for a Three-Terminal Bidirectional SCR
As shown in the figure: Can the TRIAC be triggered reliably? Also, how should the pulse low level duration T be selected? :loveliness: Why does it seem that the popularity of this forum is always low?...
harris Analog electronics
Time flies, I am still sweating in the summer, and today is the beginning of autumn~
[size=5][color=#0000ff]The title says it all. Today is the beginning of autumn~~ I’ll give you a big watermelon.jpg! :hug:[/color][/size]...
okhxyyo Talking
What is the function of the 3.3VD to DCDC3.3VD in the picture?
I don't understand the role of the 0 ohm...
chen468859 PCB Design
Why is the square wave voltage generated by the inverter circuit measured using the AC voltage range of a digital multimeter much smaller than the theoretical value?
Using the AC voltage range of a digital multimeter to measure the square wave voltage generated by the inverter circuit shows only 0.3V, but it should actually be around 10V. My instructor gave me a w...
寒香随彩蝶 Switching Power Supply Study Group
Experts~ Can you help me with the issue of IO simulation UART?
I use IO to judge whether there is data incoming. When doing the receiving and transmitting in timerA, it is normal for me to write the transmitting and receiving separately, but when they are combine...
lavender780510 Microcontroller MCU

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 823  181  1295  112  699  17  4  27  3  15 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号