EEWORLDEEWORLDEEWORLD

Part Number

Search

2159-N3-26-10

Description
118 CONTACT(S), FEMALE, RIGHT ANGLE SINGLE PART CARD EDGE CONN, SOLDER
CategoryThe connector    The connector   
File Size151KB,2 Pages
ManufacturerECS
Websitehttp://www.ecsxtal.com/
Download Datasheet Parametric View All

2159-N3-26-10 Overview

118 CONTACT(S), FEMALE, RIGHT ANGLE SINGLE PART CARD EDGE CONN, SOLDER

2159-N3-26-10 Parametric

Parameter NameAttribute value
Objectid1970589124
Reach Compliance Codeunknown
ECCN codeEAR99
Connector typeCARD EDGE CONNECTOR
Contact point genderFEMALE
DIN complianceNO
Filter functionNO
IEC complianceNO
MIL complianceNO
Mixed contactsNO
Installation methodRIGHT ANGLE
Installation typeBOARD
Number of rows loaded2
OptionsGENERAL PURPOSE
Terminal pitch3.175 mm
Termination typeSOLDER
Total number of contacts118
UL Flammability Code94V-0
CC
S
2100 Series Card Edge Connector
.125” X .250” Contact Spacing
Features
Extra large chamfered entry
Conforms to Bell-core spec TR-TSY-00078
Extended card scoops available
Replaceable contacts
Molded in polarization available between
contact, or on contact position.
• De-population of contacts per
customer specification.
• Available in selective gold plate at contact point
• Many other custom options available, including,
but not limited to:
• Single or Both Ends Open
• Shorting Contacts
Specifications
Insulator Material: Glass filled polyester, type PBT,
94 V-O, UL Rated.
Contact Material: Phosphor Bronze Alloy
Contact Plating: Gold and/or Tin over .000050” Nickel,
(See Contact Plating Options).
Current Rating:
3 amp at 30°C
Contact Resistance:
Contact to Daughter Card:
10 m
W
max.
Insulation Resistance:
5000 M
W
min.
Dielectric Withstand Voltage:
1500 V AC
Daughter Board Insertion Force:
16 oz max. per contact pair
when tested with a .071” thick
gage.
Daughter Board Withdrawal Force:
1 oz min. per contact pair
when tested with a .054” thick
gage.
Operating Temperature:
-54
B
C to +125
B
C
R
C
NO. OF CONTACTS
R
A
Recognized under the recognized component
Program of Underwriters Laboratories, Inc.
File Numbers: E146967 and E176234
POS. / CONTACTS
06/12
10/20
12/24
16/32
18/36
20/40
22/44
25/50
28/56
30/60
36/72
38/76
40/80
43/86
50/100
51/102
56/112
60/120
A
1.011 [25.68]
1.511 [38.38]
1.761 [44.73]
2.261 [57.43]
2.511 [63.78]
2.761 [70.13]
3.011 [76.48]
3.386 [86.00]
3.761 [95.53]
4.011 [101.88]
4.761 [120.93]
5.011 [127.28]
5.261 [133.63]
5.626 [143.15]
6.511 [165.38]
6.636 [168.55]
7.261 [184.43]
7.761 [197.13]
B
0.875 [22.23]
1.375 [34.93]
1.625 [41.28]
2.125 [53.98]
2.375 [60.33]
2.625 [66.68]
2.875 [73.03]
3.250 [82.55]
3.625 [92.08]
3.875 [98.43]
4.625 [117.48]
4.875 [123.83]
5.125 [130.18]
5.500 [139.70]
6.375 [161.93]
6.500 [165.10]
7.125 [180.98]
7.625 [193.68]
C
0.625 [15.88]
1.125 [28.58]
1.375 [34.93]
1.875 [47.63]
2.125 [53.98]
2.375 [60.33]
2.625 [66.68]
3.000 [76.20]
3.375 [85.73]
3.625 [92.08]
4.375 [111.13]
4.625 [117.48]
4.875 [123.83]
5.250 [133.35]
6.125 [155.58]
6.250 [158.75]
6.875 [174.63]
7.375 [187.33]
Dimensions are in inch [mm]
For reference only, can go 1 through 60 positions.
MOUNTING STYLE
.250
[6.35]
.180
[4.57]
.610
[15.49]
.250
[6.35]
1
= Clearance Hole
2
= #4-40 Threaded Insert
3
= Flush Mount
4
= #4-40 Threaded Insert
5
= No Mounting Ear
6
= Side Mounting
WWW.ECSCONN.COM
Beginner's Guide to DSP
May I ask what is going on in the picture? I am using TI's routines. After the board is connected, I click file->workspace->load space and an error occurs. Does anyone know what is going on? ?...
老牛18岁 Microcontroller MCU
Interrupt issues under MPC
I am working on MPC8260. Currently, I want to add an interrupt handler for DMA. The MPC8260 reference manual says that the interrupt number of IDMA1 is 6. I use the following function: intConnect(INUM...
freejames Embedded System
MT8888 and telephone line interface
Can anyone provide the interface circuit between MT8888 and telephone line?...
Qd650 Embedded System
EMI/EMC Design Tips
Detailed analysis of EMI/EMC design techniques...
zhdming123 PCB Design
Water Leakage Location Alarm Based on Single Chip Microcomputer
XW 1000 water leakage sensing line, when there is water contact, the two sensing lines will be short-circuited, resulting in a change in current. According to the proportional relationship between res...
zhimingli Microchip MCU
Please advise on the transplantation of STM32 in UCOSII
① Is it necessary to initialize the system clock? ② When does the task switching detection occur? Because I see that they have no system delay or anything, there are only two tasks....
乱起东城 stm32/stm8

Technical ResourceMore

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2844  2700  1147  2884  1916  58  55  24  59  39 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号