EEWORLDEEWORLDEEWORLD

Part Number

Search

ZWS100AF24/JA

Description
switching power supplies 103w 24v 4.3A
CategoryPower/power management   
File Size535KB,2 Pages
ManufacturerTDK Corporation
Websitehttp://www.tdk.com
Environmental Compliance
Download Datasheet Parametric View All

ZWS100AF24/JA Overview

switching power supplies 103w 24v 4.3A

ZWS100AF24/JA Parametric

Parameter NameAttribute value
ManufactureTDK-Lambd
Product CategorySwitching Power Supplies
RoHSYes
ProducSwitching Supplies
Open Frame/EnclosedOpen Frame
Output Power Rating103 W
Input Voltage85 VAC to 265 VAC
Number of Outputs1 Outpu
Output Voltage-Channel 124 V
Output Current-Channel 14.3 A
Commercial/MedicalCommercial
Length1.6 i
Width3.75 i
Heigh10.8 i
ApprovalsUL60950-1, EN60950-1
Dimensions1.6 in L x 3.75 in W
ZWS-AF Series
50W to 150W Single Output Low Cost, Worldwide Use
Features
u
Universal Input (85 - 265VAC)
u
Power factor Corrected
u
Input transient protected
u
2 year warranty
u
High quality design
u
Peak Power capability
Key Market Segments & Applications
Specifications
Model
AC Input Voltage range
DC Input Voltage range
Input Current (Typ) (1)
Inrush Current
Power Factor (1)
Maximum Ripple and Noise
Temperature Coefficient
Overcurrent Protection (4)
Hold Up Time (Typ) (1)
Leakage Current
Remote On / Off
Operating Temperature
Storage Temperature
Humidity (non condensing)
Withstand Voltage
Isolation Resistance
Vibration (non operating)
Shock
Safety Agency Approvals
Conducted & Radiated EMI
Immunity
Weight (Typ)
Size (W x H x D)
Warranty
VAC
VDC
A
A
-
mV
-
-
ms
-
-
-
-
-
-
-
-
-
-
-
-
g
mm
yrs
ZWS75AF
ZWS100AF
ZWS150AF
85-265VAC (47-63Hz)
120-370VDC
0.8/0.4
1.2/0.6
1.4/0.7
2.0/1.0
14/28 25°C Ambient, Cold Start
Meets EN61000-3-2 (0.99/0.95)
3.3 & 5V: 120mV; 12 to 24V: 150mV; 36 & 48V: 200mV
<0.02%/°C
>105% of Peak Current Capability
20ms
0.5mA max 0.1mA (Typ) at 100VAC 0.16mA (Typ) at 230VAC
See installation manual (Not available with /A cover option)
Convection cooling - See table on page 2
0.7m/s air -10°C to +70°C, derate linearly to 70% load from 60°C to 70°C (2)
-30° to +85°C
Operating: 30 - 90% RH, storage 10-95% RH
I/P~Grnd 2kVAC (20mA), I/P~O/P 3kVAC (20mA), O/P~Grnd 500VAC (100mA) for 1 min.
>100M at 25C & 70%RH, Output to Ground 500VDC
10 - 55Hz (1 minute sweep), 19.6m/s
2
constant X, Y, Z 1 hour
< 196.1 m/s
2
UL60950-1, CSA60950-1, EN60950-1, EN50178, CE Mark
designed to meet EN55011, EN55022-B, FCC Class B, VCCI-B
designed to meet EN61000-4-2,-3,-4,-5,-6,-8,-11
210
290
380
500
55 x 26 x 195
55 x 32 x 222
62 x 35 x 222
75 x 40 x 222
Two Years
ZWS50AF
Notes:
(1) 100/200VAC
(2) ZWS150AF -10 to 60°C, derate linearly to 70% load from 50°C to 60°C
(3) The peak current draw must not exceed a 10 second duration with a duty cycle of 35%
(4) Constant current limit with automatic recovery. Do not operate in a over-load or shorted output condition for more than 30 seconds.
(5) An overvoltage condition on the output will shut down the power supply. The power supply must be re-set by cycling the AC input.
For New Designs, See ZWSBAF Series
1-800-526-2324 • www.us.tdk-lambda.com/lp/
1
Disclaimer: us.tdk-lambda.com/lp/legal.htm
Maintenance of Fukang LPG dual fuel car
LPG (Liquefied Petroleum Gas) is an efficient, safe and clean alternative fuel for automobiles. It is the most mature low-pollution automobile fuel for promotion. The promotion and application of LPG ...
frozenviolet Automotive Electronics
GaN Power HEMT > 650 V: Parametric Analysis and Comparison with SiC MOSFET
Over the past few years, SiC MOSFETs have dominated high voltage (600V) and high power applications. Advantages such as thermal conductivity, high critical field, greatly improved switching efficiency...
兰博 RF/Wirelessly
Free e-contest format
[i=s]This post was last edited by paulhyde on 2014-9-15 09:40[/i] :P Everyone is welcome to express their opinions!...
flomingo Electronics Design Contest
stm32DMA peripheral address calculation problem
I would like to ask how the DMA peripheral address is calculated. For example, if ADC1 uses DMA1 channel 5, how is the data register address of ADC1 calculated? I checked the official manual, but it d...
2315862 stm32/stm8
Performance comparison of three classic wireless transceiver modules [ZT]
[i=s] This post was last edited by paulhyde on 2014-9-15 09:07 [/i] Performance comparison of three classic wireless transceiver modules The CC1100 module uses the CC1100 high-performance monolithic w...
yewen521 Electronics Design Contest
Voltage controlled current source composed of opa547
I want to use op07 and opa547 chips to form a voltage-controlled current source. The problem I encounter now is that the voltage at the positive and negative ends of opa547 are not equal. Why is this?...
alllllll Analog electronics

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1693  2112  2142  1713  2356  35  43  44  48  14 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号