125W Triple Output with PFC Function
Features :
P P T- 1 2 5
series
Universal AC input / Full range
Built-in active PFC function
Protections: Short circuit / Overload / Over voltage
PWM control and regulated
High power density 6.117W/inch
3
LED indicator for power on
100% full load burn-in test
125W with 18CFM FAN
5"x3" compact size
3 years warranty
SPECIFICATION
MODEL
OUTPUT NUMBER
DC VOLTAGE
RATED CURRENT
PPT-125A
CH1
3.3V
10A
CH2
5V
8A
CH3
12V
0.5A
PPT-125B
CH1
5V
11.5A
CH2
12V
3A
CH3
-12V
0.5A
PPT-125C
CH1
5V
11A
CH2
15V
2.5A
CH3
-15V
0.5A
PPT-125D
CH1
5V
7A
CH2
24V
2.5A
CH3
12V
0.5A
CURRENT RANGE (convection)
1 ~ 10A
RATED POWER (convection)
79W
OUTPUT
RATED POWER (18CFM FAN)
98.81W
VOLTAGE ADJ. RANGE
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
HOLD UP TIME (Typ.)
VOLTAGE RANGE
FREQUENCY RANGE
POWER FACTOR (Typ.)
INPUT
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
OVERLOAD
PROTECTION
OVER VOLTAGE
WORKING TEMP., HUMIDITY
WORKING TEMP.
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SAFETY STANDARDS
SAFETY & WITHSTAND VOLTAGE
ISOLATION RESISTANCE
EMC
(Note 4)
EMC EMISSION
EMC IMMUNITY
MTBF
OTHERS
DIMENSION
PACKING
NOTE
0.8 ~ 8A 0.05 ~ 0.5A 1 ~ 11.5A 0.3 ~ 3A
99.5W
124.46W
CH1:4.75 ~ 5.25V
3.0%
5.0%
0.5%
3.0%
0.5%
3.0%
0.05 ~ 0.5A 1 ~ 11A
100W
125.15W
0.25 ~ 2.5A 0.05 ~ 0.5A 1 ~ 7A
101W
126.43W
0.25 ~ 2.5A 0.05 ~ 0.5A
CURRENT RANGE (18CFM FAN)
1 ~ 12.5A 0.8 ~ 10A 0.05 ~ 0.63A 1 ~ 14.38A 0.3 ~ 3.75A 0.05 ~ 0.63A 1 ~ 13.75A 0.25 ~ 3.13A 0.05 ~ 0.63A 1 ~ 8.75A 0.25 ~ 3.13A 0.05 ~ 0.63A
RIPPLE & NOISE (max.)
Note.2
100mVp-p 100mVp-p 120mVp-p 100mVp-p 120mVp-p 120mVp-p 100mVp-p 150mVp-p 150mVp-p 100mVp-p 240mVp-p 120mVp-p
CH1:3.13 ~ 3.46V
VOLTAGE TOLERANCE
Note.3
3.0%
5.0%
0.5%
3.0%
0.5%
3.0%
6.0%
0.5%
5.0%
6.0%
0.5%
5.0%
CH1:4.75 ~ 5.25V
3.0%
5.0%
0.5%
3.0%
0.5%
3.0%
6.0%
0.5%
5.0%
CH1:4.75 ~ 5.25V
3.0%
5.0%
0.5%
3.0%
0.5%
3.0%
6.0%
0.5%
5.0%
1000ms, 30ms/230VAC
24ms/230VAC
90 ~ 264VAC
47~63Hz
PF>0.93/230VAC
75%
2000ms, 30ms/115VAC at full load
24ms/115VAC at full load
127 ~ 370VDC
PF>0.98/115VAC at full load
78%
78%
78%
1.7A/115VAC
0.75A/230VAC
COLD START 24A/230VAC
<2mA / 240VAC
130 ~ 160% rated output power
Protection type : Fold back current limiting, recovers automatically after fault condition is removed
CH1:3.6 ~ 4.45V
CH1:5.75 ~ 6.75V
CH1:5.75 ~ 6.75V
Protection type : Hiccup mode, recovers automatically after fault condition is removed
-20 ~ +70 (Refer to "Derating Curve")
20 ~ 90% RH non-condensing
-40 ~ +85
0.05%/
, 10 ~ 95% RH
(0 ~ 50
CH1:5.75 ~ 6.75V
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
UL60950-1, TUV EN60950-1 approved
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
Compliance to EN55022 (CISPR22) Class B, EN61000-3-2,-3
Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, light industry level, criteria A
94.7Khrs min. MIL-HDBK-217F (25
127*76.2*34.6mm (L*W*H)
0.37Kg; 36pcs/14.3Kg/0.79CUFT
)
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies.
(as available on http://www.meanwell.com)
5. Heat Sink HS1,HS2 & HS3 can not be shorted.
File Name:PPT-125-SPEC 2011-08-18