EEWORLDEEWORLDEEWORLD

Part Number

Search

ZF6UGRSP01BMAUC

Description
PUSHBUTTON SWITCH, 6PDT, LATCHED, 0.01A, 50VDC, THROUGH HOLE-RIGHT ANGLE, ROHS COMPLIANT
CategoryMechanical and electronic products    switch   
File Size383KB,10 Pages
ManufacturerC&K
Environmental Compliance
Download Datasheet Parametric View All

ZF6UGRSP01BMAUC Overview

PUSHBUTTON SWITCH, 6PDT, LATCHED, 0.01A, 50VDC, THROUGH HOLE-RIGHT ANGLE, ROHS COMPLIANT

ZF6UGRSP01BMAUC Parametric

Parameter NameAttribute value
Is it lead-free?Lead free
Is it Rohs certified?conform to
MakerC&K
package instructionROHS COMPLIANT
Reach Compliance Codecompliant
ECCN codeEAR99
Actuator materialPOLYESTER
Actuator stroke4.699 mm
Actuator typePUSHBUTTON
body width9 mm
body height6.9 mm
Body length or diameter45 mm
center contact materialBRASS
Contact (AC) maximum rated R load.04A@50VAC
Maximum contact current (AC)0.04 A
Maximum contact current (DC)0.01 A
Contact (DC) maximum rated R load.01A@50VDC
Contact resistance0.02 mΩ
contact timeMAKE-BEFORE-BREAK
Maximum contact voltage (AC)50 V
Maximum contact voltage (DC)50 V
Electrical life35000 Cycle(s)
End contact materialBRASS
Insulation resistance1000000000 Ω
JESD-609 codee4
Manufacturer's serial numberF
Installation featuresTHROUGH HOLE-RIGHT ANGLE
Maximum operating force7.5 N
Maximum operating temperature70 °C
Minimum operating temperature-40 °C
sealTOP AND BOTTOM SEALED
surface mountNO
Switch actionLATCHED
switch function6PDT
Switch typePUSHBUTTON SWITCH
Terminal surfaceGold (Au) - with Nickel (Ni) barrier
Terminal materialBRASS
Termination typeSOLDER
Base Number Matches1
F Series
Pushbutton Switches
A
Features/Benefits
Up to 10 poles per module
Various contact terminals
Various mounting & switch
ganging configurations
Pushbutton
Typical Applications
Audio selection
Digital equipment interface
Medical equipment interface
Mechanical indicator buttons
RoHS compliant
Specifications
SWITCHING POWER: F module max. AC/DC: Silver: 50 VA/15W,
Gold: 1 VA/300 mW.
SWITCHING VOLTAGE: F module max. AC/DC: Silver: 125/30V,
Gold: 50/30 V.
SWITCHING CURRENT: F module max. AC/DC: Silver: 0.5A/0.5A,
Gold: 0.04A/0.01A.
CARRYING CURRENT: Max at du = 20C: Silver: < 2A, Gold: <0.5A.
DIELECTRIC STRENGTH (50 Hz, 1 min.): Chassis/contact: ^1500V
Between contacts: ^1500V.
OPERATING LIFE “OA/EE” (24V/200mA): >105 operations
“GR”: >3.5 x 104 operations.
CONTACT RESISTANCE: Initial: Typical %10 mΩ, max. 20 mΩ
After operating life: %100 mΩ
INSULATION RESISTANCE: ^109
between open contacts,
^109
between chassis and contacts.
CAPACITANCE (at f = 10 kHz): %0.7 pF between 2 contacts.
TOTAL TRAVEL/LATCHING TRAVEL: 4.7mm/3.3mm (.185 inch/
.130 inch).
All models and options are RoHS compliant and compatible.
NOTE:
All models and options are RoHS compliant and compatible.
NOTE:
Specifications and materials listed above are for switches with standard options.
For information on specific and custom switches, consult Customer Service Center.
TYPICAL F OPERATING FORCE: 2U: 6.5N (650 grams); 4U: 6.5N
(650 grams); 6U: 7.5N (750 grams); 8U: 9.0N (900 grams); 10U:
9.0N (900 grams).
EUROPEAN TYPICAL SF OPERATING FORCE:
2U: 3.5N±0.5N (350 grams±100 grams); 4U: 5N±1N (500
grams±100 grams); 6U: 6.5N±1N (650 grams±100 grams); 8U:
9.0N±1N (900 grams±100 grams).
OPERATING TEMPERATURE RANGE: -40˚C to 70˚C.
Materials
HOUSING: Polycarbonate UL 94V-0 or polyester UL 94V-0.
ACTUATOR: Polyester UL 94V-0.
MOVABLE CONTACTS: Bimetal brass, silver plated, gold plate
over nickel.
STATIONARY CONTACTS & TERMINALS: Brass, silver plated,
gold plated.
TERMINAL BOARD: Polyester UL 94V-0.
RETURN SPRING: Music wire.
TERMINAL SEAL: RTV adhesive sealant.
CHASSIS: Steel.
LOCKOUT PIN: Steel.
BLOCKERS: Steel.
Build-A-Switch
To order, simply select desired option from each category and place in the appropriate box. Available options are shown
and described on pages A-89 thru A-97. For additional options not shown in catalog, consult Customer Service Center.
If requesting only a switch, select either a North American or European switch as noted below. Chassis and buttons are sold
separately. If multiple stations are selected, we will assume all switches are the same unless noted otherwise.
North American Order Code - Switch Only
Designation
F
F Series
FLT
Light touch F series
ZF
Central mounted F series
Contact Arrangement
2U
2PDT
Mechanical Function
4U
4PDT
OA
Momentary
6U
6PDT
EE
Alternate (push-push)
8U
SPDT
GR
Interlock
10U
1OPDT
AOR
Central release
OASP
Momentary with lockout
GRSP
Interlock with lockout
Terminal Sealing
(NONE)
None
TB
Top/bottom
Terminal Style
(NONE)
Solder lugs & PC pins
01A
Cut solder lugs
01B
Cut PC pins, for other configurations,
consult factory
Electrical Function
(NONE)
BBM
M
MBB (special)
Contact Material
(NONE)
Silver, AG
AU
Gold
Dress nut*
*Central mounted F series only
(NONE)
No dress nut
B
Black
C
Chrome
Dimensions are shown: Inches (mm)
Specifications and dimensions subject to change
A-88
www.ck-components.com
In Ubuntu single-user mode, the VI command is invalid. What command should I use to edit the file?
As the title says, I tried to enter Ubuntu single-user mode today. Commands such as mkdir, mk echo, rm, ls, etc. can all be used, but vi or vim gedit cannot be used. What command can I use to modify t...
xiaoqzq Linux and Android
Can I use ARM LPC2138 to solve Problem F?
[i=s]This post was last edited by paulhyde on 2014-9-15 08:59[/i] Can I use lpc2138 to solve problem F? Can the digital filtering time plus the AD/DA conversion transmission time guarantee a sampling ...
bmr1179 Electronics Design Contest
The ST-LINK on the three-in-one board cannot display the memory data correctly
I wrote a program that writes to an array in memory. Using software simulation, it seems that all the data has been rewritten. However, after running the simulator, I found that only a part of it has ...
afreebird stm32/stm8
The main functions of the engineering safety black box have been completed
[i=s]This post was last edited by sipower on 2020-6-14 23:31[/i]There are a lot of things to do during this period, and I basically use my spare time to do them. These are the main functions in my cur...
sipower ST MEMS Sensor Creative Design Competition
This error occurs in evc, why can't I use AfxMessageBox?
void CHello2Dlg::OnButton1() { // TODO: Add Ayour control notification handler code here AfxMessageBox("Simple message box."); } Compiling... hello2Dlg.cpp D:\myVC\eVC\hello2\hello2Dlg.cpp(65) : error...
wb1985432 Embedded System
Brothers, please help me, thank you for your hard work. Use VERILOG to simulate a three-story elevator.
Brothers, our school's homework is due soon. I really won't trouble you. Just implement some basic functions....
蹦2008 Embedded System

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2380  153  2413  493  202  48  4  49  10  5 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号