12 ~ 18W AC-DC Single Output Interchangeable Wall-mounted type
Features :
GE18
series
Interchangeable AC plugs (plug kit sold seperately)
Universal AC input / Full range
No load power consumption< 0.3W/230VAC for 5~24V(<0.5W/230VAC for 48V)
Meet energy star(CEC) level V for 5~24V(level
for 48V)
Meet EISA 2007 (Energy Independence and Security Act)
Class power (without earth pin)
Protections: Short circuit / Overload / Over voltage
Fully enclosed plastic case
LED indicator for power on
Pass LPS
Approvals: UL / CUL / TUV / CB / FCC / CE / C-Tick
2 years warranty
AC INLET PLUG
TUV
Rheinland
Product Safety
geprUfre
Sicherheit
TYPE
Australian type
ORDER NO.
AC plug-AU
U.K type
AC plug-UK
European type
AC plug-EU
US type
AC plug-US
Mix four type
AC plug-MIX
SPECIFICATION
I I
I I
I I
I I
I I
I I
I I
POWER SUPPLY MAIN BODY ORDER NO. GE18
I
05-P1J GE18
I
07-P1J GE18
I
09-P1J GE18
I
12-P1J GE18
I
15-P1J GE18
I
18-P1J GE18
I
24-P1J GE18
I
48-P1J
I I
I I
I I
I I
I I
SAFETY MODEL NO.
DC VOLTAGE
RATED CURRENT
CURRENT RANGE
OUTPUT
RATED POWER (max.)
VOLTAGE TOLERANCE
Note.4
LINE REGULATION
LOAD REGULATION
Note.5
Note.6
I I
I I
I I
FRA018-S05-
I
FRA018-S07-
I
FRA018-S09-
I
FRA018-S12-
I
FRA018-S15-
I
FRA018-S18-
I
FRA018-S24-
I
FRA018-S48-
I
Note.2
5V
7.5V
1.73A
0 ~ 1.73A
13W
75mVp-p
5.0%
1.0%
5.0%
9V
2.0A
0 ~ 2.0A
18W
100mVp-p
5.0%
1.0%
5.0%
12V
1.5A
0 ~ 1.5A
18W
120mVp-p
3.0%
1.0%
3.0%
15V
1.2A
0 ~ 1.2A
18W
150mVp-p
3.0%
1.0%
3.0%
18V
1.0A
0 ~ 1.0A
18W
180mVp-p
3.0%
1.0%
3.0%
24V
0.75A
0 ~ 0.75A
18W
240mVp-p
3.0%
1.0%
3.0%
48V
0.375A
0 ~ 0.375A
18W
300mVp-p
3.0%
1.0%
3.0%
2.4A
0 ~ 2.4A
12W
5.0%
1.0%
5.0%
RIPPLE & NOISE (max.)
Note.3
50mVp-p
SETUP, RISE, HOLD UP TIME
4000ms, 100ms, 30ms / 230VAC
90 ~ 264VAC
135 ~ 370VDC
VOLTAGE RANGE
FREQUENCY RANGE
INPUT
EFFICIENCY (Typ.)
AC CURRENT
INRUSH CURRENT (max.)
LEAKAGE CURRENT (max.)
OVERLOAD
PROTECTION
OVER VOLTAGE
WORKING TEMP.
WORKING HUMIDITY
47 ~ 63Hz
72%
0.7A / 100VAC
75%
0.4A / 230VAC
75%
4000ms, 100ms, 10ms / 115VAC at full load
78%
80%
80%
81%
81%
COLD START 40A / 100VAC
80A / 230VAC
0.25mA / 240VAC
110% ~ 200% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
115% ~ 135%
Protection type : Clamp by zener diode
-10 ~ +50
(Refer to output load derating curve)
20% ~ 90% RH non-condensing
ENVIRONMENT STORAGE TEMP., HUMIDITY
-20 ~ +85 , 10 ~ 95% RH
TEMP. COEFFICIENT
0.03% / (0 ~ 50 )
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
VIBRATION
SAFETY STANDARDS
WITHSTAND VOLTAGE
SAFETY & ISOLATION RESISTANCE
EMC
EMI CONDUCTION & RADIATION
HARMONIC CURRENT
EMS IMMUNITY
LIFE
OTHERS
MTBF
DIMENSION
PACKING
UL60950-1, CSA C22.2, TUV EN60950 -1 approved
I/P-O/P:4242VDC
I/P-O/P:100M Ohms / 500VDC / 25 / 70% RH
Compliance to EN55022 class B, FCC PART 15 / CISPR22 class B
Compliance to EN61000-3-2,3
Compliance to EN61000-4-2,3,4,5,6,8,11, light industry level, criteria A
2 years : 100% load 30 , 8 hours / day
100Khrs min.
MIL-HDBK-217F (25
)
81*43*40.5mm (L*W*H)
134g ; 60pcs / 12.32kg / CARTON
Standard type P1J: 2.1 * 5.5
See page2
* 11mm turning fork type, center positive for stock ; Other type available by customer requested
DC OUTPUT PLUG
CONNECTOR CABLE
NOTE
1.All parameters are specified at 230VAC input, rated load, 25 70% RH ambient.
2.DC voltage: The output voltage set at point measure by plug terminal & 50% load.
3.Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1uf & 47uf capacitor.
4.Tolerance: includes set up tolerance, line regulation, load regulation.
5.Line regulation is measured from low line to high line at rated load.
6.Load regulation is measured from 10% to 100% rated load
7.Main body unit and AC inlet plug should be ordered seperately ; it needs to be used along with any of the AC inlet plug.
MeanWell Direct Tel: +44 (0)118 970 3858 E-mail: sales@meanwelldirect.co.uk
File Name:GE18-SPEC 2009-03-26
I I