EEWORLDEEWORLDEEWORLD

Part Number

Search

5145.A04WF150C0.511

Description
Mains Power Connector, 6A, 250/125VAC, Male, Solder Terminal, ROHS COMPLIANT
CategoryThe connector    The connector   
File Size1MB,6 Pages
ManufacturerSCHURTER
Websitehttp://www.schurterinc.com/
Environmental Compliance
Download Datasheet Parametric View All

5145.A04WF150C0.511 Overview

Mains Power Connector, 6A, 250/125VAC, Male, Solder Terminal, ROHS COMPLIANT

5145.A04WF150C0.511 Parametric

Parameter NameAttribute value
Is it lead-free?Lead free
Is it Rohs certified?conform to
package instructionROHS COMPLIANT
Reach Compliance Codecompliant
ECCN codeEAR99
Other featuresSTANDARDS: IEC/EN 60320-1; IEC/EN 60950; UL 94V-0; CSA; VDE; QUICK CONNECT
Connector typeMAINS POWER CONNECTOR
Contact to complete cooperationTIN/TIN COPPER
Contact completed and terminatedTIN/TIN COPPER
Contact point genderMALE
Contact materialNOT SPECIFIED
Coupling typeSNAP
DIN complianceNO
IEC complianceYES
JESD-609 codee3/e2
MIL complianceNO
Power Connector Ratings6A, 250/125VAC
Installation typePANEL
OptionsGENERAL PURPOSE
Shell materialPOLYETHYLENE
Termination typeSOLDER
Total number of contacts3
Base Number Matches1
Power entry modules with line filter
www.schurter.com/pg06
Inlet filter, front side mounting, circuit breaker TA45 2-pole
545
Standard- or Medical-Filter
Screw-On Version
C14
70° C
Description
- Panel Mount:
Screw-on from front side
- 3 Functions:
Appliance Inlet Protection class I, circuit breaker type TA45 2-
pole, Line filter in standard and medical version
- Quick connect terminals 6.3 x 0.8 mm
- Alternative: version without line filter 6145
- We recommend for new applications the new type DF12
Characteristics
- All single elements are already wired
Unwired versions available on request
- Line switch non-illuminated or illuminated
Thermal overload protection
Optional with undervoltage release or remote trip release
- Qualified for use in equipment according IEC/EN 60950
Weblinks
Approvals
Approvals, RoHS, CHINA-RoHS, e-Store, SCHURTER-Stock-Check,
Distributor-Stock-Check
- VDE License Number: 117118
- UL License Number: E72928
Technical Data
Ratings IEC
Ratings UL/CSA
Leakage Current
Dielectric Strength
1 - 10 A @ Ta 40 °C / 250 VAC; 50 Hz
1 - 15 A @ Ta 40 °C / 125 VAC; 60 Hz
standard < 0.5 mA (250 V / 60 Hz)
medical < 5 µA (250 V / 60 Hz)
> 1.7 kVDC between L-N
> 2.7 kVDC between L/N-PE
Test voltage (2 sec)
-10 °C to 55 °C
10/055/21acc. to, IEC 60068-1
from front side IP 40 acc. to IEC 60529
Suitable for appliances with protection
class I acc. to IEC 61140
Quick connect terminals 6.3 x 0.8 mm
Screw-on: max 8 mm
Mounting screw torque max 0.5 Nm
Thermoplastic, black, UL 94V-0
Appliance-Inlet/-Outlet
C14 acc. to IEC/EN 60320-1,
UL 498, CSA C22.2 no. 42 (for cold
conditions) pin-temperature 70 °C, 10 A,
Protection class I
Acc. IEC/EN 60934, UL 1077, CSA
22.2 no. 235
2-pole rocker switch, illuminated or non-
illuminated. Optional with undervoltage-
or remote trip release
Short circuit capacity Icn:
at In < 3A/240VAC : 10 x In
at In ≥ 3A/240VAC : 300A
Rocker switch 2-pole non-illuminated or
illuminated acc. to IEC 61058-1
Technical details
Standard and Medical Version, IEC
60939, IEC 60601-1, UL 1283, UL 544,
EN 133 200, CSA C22.2 no. 8
Technical details
> 100'000 h acc. to MIL-HB-217 F
Circuit breaker
Allowable Operation Temp.
Climatic Category
Degree of Protection
Protection Class
Terminal
Panel Thickness s
Material: Housing
Line Switch
Line Filter
MTBF
EMC products

Why does the prompt disappear when the mouse points to a variable or function in CCStudio?
When I used CCStudio to do DSP experiments before, when I pointed the mouse at a variable or function in the program, the relevant information would be automatically displayed. Moreover, when writing ...
dmz04 Embedded System
What are the differences between DSP, MCU and MPU?
[size=4] The CPU (Central Processing Unit) has developed into three branches, one is DSP (Digital Signal Processing/Processor), and the other two are MCU (Micro Control Unit) and MPU (Micro Processor ...
fish001 DSP and ARM Processors
What does it mean when these words appear on the burned film?
Can\'t Set Breakpoint: Cannot set/verify breakpoint at 0x2CA Breakpoint Manager: An error was encountered attempting to set a breakpoint usedfor end of program detection.还有一句是:The address specified in...
liuyanying Analogue and Mixed Signal
Help: How to get the space occupied by a directory
Dear experts, I would like to ask: How can I get the size of the space occupied by a directory (that is, the sum of the space occupied by all files in the directory)?...
wangshaolei8701 Embedded System
Who can write a wavelet transform program based on DSP?
The DSP model is 5402, thank you very much...
songxinmeng123 DSP and ARM Processors
CPLD as a DSP peripheral to read and write data program code
When CPLD is used as a DSP peripheral, DSP puts data in IO space, CPLD reads data, and controls the peripheral program according to the corresponding address and information. I bought a CPLD+DSP devel...
happysee FPGA/CPLD

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 956  1481  583  1726  2309  20  30  12  35  47 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号