EEWORLDEEWORLDEEWORLD

Part Number

Search

231-103-H7ZL23-53PD-01

Description
Circular Connector Adapter, 53 Contact(s), Stainless Steel, Male-Female
CategoryThe connector    The connector   
File Size436KB,1 Pages
ManufacturerGlenair
Websitehttp://www.glenair.com/
Download Datasheet Parametric View All

231-103-H7ZL23-53PD-01 Overview

Circular Connector Adapter, 53 Contact(s), Stainless Steel, Male-Female

231-103-H7ZL23-53PD-01 Parametric

Parameter NameAttribute value
Reach Compliance Codecompli
Other featuresSTANDARD: MIL-DTL-38999, POLARIZED
Connector typeCIRCULAR CONNECTOR ADAPTER
Contact point genderMALE-FEMALE
Coupling typeBAYONET
DIN complianceNO
empty shellNO
Filter functionNO
IEC complianceNO
MIL complianceYES
Manufacturer's serial number231-103-H7
Mixed contactsNO
Installation typePANEL
OptionsHERMETIC
Shell surfaceNICKEL
Shell materialSTAINLESS STEEL
Total number of contacts53
Base Number Matches1
Bulkhead
Feed-Thrus
Connector Series
231
-
D38999 Series I Type
Shell Style
H7
- Jam Nut Mount
Connector Type
103
-
Hermetic Bulkhead
Feed-Thru
Connector Material and Finish
FT
- Carbon Steel, Fused Tin
Z1
- CRES, Passivated
ZL
- CRES, Nickel Finish
231-103-H7
Jam Nut Mount Hermetic Bulkhead Feed-Thru
MIL-DTL-38999 Series I Type
Shell Size
09
11
13
15
17
19
21
23
25
Insert Arrangement
Per MIL-DTL-38999 Series I
MIL-STD-1560
Alternate Key
Position
A, B, C, D
(N = Normal)
2.040 (51.8)
1.310 (33.3)
.585
(14.9)
Ref
B
231
-
103
-
H7 Z1 11
-
35
P N
-
01
A Thread
Hole For .032 Dia
Safety Wire, 3
Equally Spaced
.125 (3.2)
.150 (3.8) Max
Panel
Accomodation
Contact Termination
P
- Pin on Jam Nut Side
S
- Socket on Jam Nut Side
E Dia
Panel Accomodation
01
- .0625″ (Min) .125″ (Max)
02
- .0625″ (Min) .250″ (Max)
03
- .0625″ (Min) .500″ (Max)
F
C
Recommended Panel Cut-Out
TABLE I: CONNECTOR DIMENSIONS
E
SHELL
SIZE
09
11
13
15
17
19
21
23
25
A THREAD
CLASS 2A
.688-24 UNEF
0.812-20 UNEF
1.000-20 UNEF
1.125-18 UNEF
1.250-18 UNEF
1.375-18 UNEF
1.500-18 UNEF
1.625-18 UNEF
1.750-18 UNS
B DIA
MAX
.573(14.6)
.701(17.8)
.851(21.6)
.976(24.8)
1.101(28.0)
1.208(30.7)
1.333(33.9)
1.458(37.0)
1.583(40.2)
C
HEX
.875(22.2)
1.000(25.4)
1.188(30.2)
1.312(33.3)
1.438(36.5)
1.562(39.7)
1.688(42.9)
1.812(46.0)
2.000(50.8)
D
FLATS
1.062(27.0)
1.250(31.8)
1.375(34.9)
1.500(38.1)
1.625(41.3)
1.812(46.0)
1.938(49.2)
2.062(52.4)
2.188(55.6)
E DIA
±.005(0.1)
.703(17.9)
.827(21.0)
1.015(25.8)
1.140(29.0)
1.265(32.1)
1.390(35.3)
1.515(38.5)
1.640(41.7)
1.765(44.8)
F +.000-.005
(0-0.1)
.669(17.0)
.769(19.5)
.955(24.3)
1.084(27.5)
1.208(30.7)
1.333(33.9)
1.459(37.1)
1.580(40.1)
1.709(43.4)
D
Insert Arrangement per
MIL-DTL-38999, Series l
MIL-STD-1560
APPLICATION NOTES
1.
2.
3.
Power to a given contact on one end will result in power to contact directly
opposite, regardless of identification letter.
Hermeticity = less than 1 x 10
-4
cc/sec at one atmosphere. Not for use in liquid
atmosphere.
Material/finish:
Shell, nut – CRES/passivated, carbon steel/fused tin or CRES/nickel per QQ-N-290.
4.
Contacts – Gold Plated. Pin: alloy 52; Skt.: copper alloy
Insulator – fused vitreous glass/N.A.
Seals – fluorosilicone rubber/N.A.
Metric dimensions (mm) are indicated in parentheses.
© 2008 Glenair, Inc.
www.glenair.com
CAGE CODE 06324
Printed in U.S.A.
E-Mail: sales@glenair.com
GLENAIR, INC.
1211 AIR WAY
GLENDALE, CA 91201-2497
818-247-6000
FAX 818-500-9912
E-2
[Project source code] Use of digital filter based on FPGA
There are two main ways, one is to use the matlab filter toolbox to design and generate Verilog or VHDL code, the other is to use the matlab filter toolbox to design and export coefficients, and then ...
小梅哥 FPGA/CPLD
Starting from analyzing the computer power supply--Detailed analysis of the working principle of the switching power supply
[b][size=5][color=#0000ff][backcolor=rgb(245, 248, 253)][font=simsun]The article reproduced below is from a foreign website a few years ago. For many power supply beginners, this article is still very...
qwqwqw2088 Analogue and Mixed Signal
Show the process of WEBENCH design + PH sensor circuit design
1. After selecting PH in the webench initial test interface, enter the interface as follows to select the sensor2. LMP91200 is a chip specially designed for measuring PH by TI, as shown below3. You ca...
一潭清水 Analogue and Mixed Signal
How to connect ARM9 ADC to external circuits
How to connect ARM9's ADC to an external amplifier circuit?...
wujieling ARM Technology
Nucleo-F413ZH Development Board Review_Unboxing and Development Environment Update
First of all, I would like to thank the organizers for giving me the opportunity to test it, so that I can experience it earlier. Among the three development boards, F411, F412 and F413, if F411 is a ...
jinglixixi stm32/stm8
A fatal error occurred in the quartus functional simulation. Fatal error: Module: quartus_sim.exe Exception: Access Violat
*** Fatal error: Module: quartus_sim.exe Exception: Access Violation Stack Trace: 01a314e6: SDB_DFF_INFO::set_last_clock_value() + 0x34 (tsm_sdb) 01a03144: EDS_ENGINE::propagate() + 0xb0 (TSM_EDS) 01a...
69056001 Embedded System

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 864  2423  1228  1828  320  18  49  25  37  7 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号