EEWORLDEEWORLDEEWORLD

Part Number

Search

FC2311-0000-0050-L

Description
force sensors & load cells compression loadCell -25 lbs 0.5-4.5vout
CategoryThe sensor   
File Size111KB,4 Pages
ManufacturerMeasurement Specialties(TE Connectivity)
Websitehttp://www.te.com/usa-en/products/brands/meas.html?tab=pgp-story
Download Datasheet Parametric View All

FC2311-0000-0050-L Online Shopping

Suppliers Part Number Price MOQ In stock  
FC2311-0000-0050-L - - View Buy Now

FC2311-0000-0050-L Overview

force sensors & load cells compression loadCell -25 lbs 0.5-4.5vout

FC2311-0000-0050-L Parametric

Parameter NameAttribute value
ManufactureMeasurement Specialties
Product CategoryForce Sensors & Load Cells
Operating Force50 lbf
Accuracy1 %
Output TypeBasic
Mounting StyleCable
Heigh10.2 mm
Maximum Operating Temperature+ 85 C
Minimum Operating Temperature- 40 C
Operating Supply Voltage5 V
Sensor TypeLoad Cell
Width25 mm
FC23
Compression Load Cell
50 – 2000 lbf Ranges
High Level or mV
Interchangeable
Compact Load Button Design
Industry Standard Packaging
CE Compliance
DESCRIPTION
The FC23 is a
high compression force sensor that creates new markets previously unrealizable due to
cost and performance constraints. The FC23 offers normalized zero and span for interchangeability and is
thermally compensated for changes in zero and span with respect to temperature.
The FC23 incorporates MEAS’ proprietary Microfused™ technology which employs micromachined
silicon piezoresistive strain gages fused with high temperature glass to a high performance stainless steel
substrate. Microfused™ technology eliminates age-sensitive organic epoxies used in traditional load cell
designs providing excellent long term span and zero stability. The FC23 measures direct force and is therefore
not subject to lead-die fatigue failure common with competitive designs which use a pressure capsule
embedded within a silicone gel-filled cavity. Operating at very low strains, Microfused™ technology provides an
essentially unlimited cycle life expectancy, superior resolution, and high over-range capabilities.
The FC23 brings your OEM product to life whether you need thousands or millions of load cells
annually. Although the standard model is ideal for a wide range of applications, our dedicated design team at
our Load Cell Engineering Center is ready to provide you with custom designs for your OEM applications.
Please refer to models FS20 and FC22 for lower force applications.
FEATURES
Interchangeable
Low Noise
Robust: High Over-Range Capability
High Reliability
Low Deflection
Low Off Center Errors
Fast Response Time
Long Cycle Life Expectancy
APPLICATIONS
Batch Weighing
Robotics End-Effectors
Variable Force Control
Load and Compression Sensing
Assembly Line Force Measurement
Pumps
Hoist and Winch Loads
Weighing
STANDARD RANGES
Range
0 to 50
0 to 100
0 to 250
0 to 500
0 to 1000
0 to 2000
FC23
lbf
www.meas-spec.com
1/4
August 2012
An electronic engineer's salary increased from 5k to 20k in 3 years after graduation (transferred)
A while ago, I saw an article online about a beautiful programmer who graduated for 3 and a half years and whose salary increased from 2k to 8k and she changed 3 jobs. I felt the same way after readin...
unbj Talking
Selection of Practical Electronic Circuits
[i=s]This post was last edited by paulhyde on 2014-9-15 09:39[/i] It includes commonly used measurement circuits, sensor circuits, detection circuits, etc., and has certain reference value....
sweeden Electronics Design Contest
Modelsim simulation error after ROM instantiation
This error occurred: Instantiation of 'altsyncram' failed. The design unit was not found. Please give me some advice. Thank you!...
zhenpeng25 FPGA/CPLD
Batch question skip ask execution
@echo off md E:\网络游戏\世界魔兽xcopy /e "U:\世界魔兽" "E:\网络游戏\世界魔兽" start U:\世界魔兽\BigFoot.exe echo copy successful pause&exit This batch process always asks to execute. How can I not execute it? Thank you...
springmorn Embedded System
The wince420 serial port is opened successfully, but the parameters cannot be obtained.
The code is as follows [code] if (m_hComm != INVALID_HANDLE_VALUE) // Already opened, return directly { return TRUE; } m_hComm = CreateFile(_T("COM1:"), // Open serial port COM1 in synchronous read mo...
naebemn Embedded System
【TI's First Low Power Design Competition】Three-axis acceleration demonstration
[i=s]This post was last edited by ltbytyn on 2014-11-17 23:18[/i] Hardware: MSP430FR5969 Launchpad+430BOOST-SHARP96+ADXL345 ADXL345 digital three-axis gravity acceleration chip, supports I2C\SPI two i...
ltbytyn Microcontroller MCU

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2772  1792  2733  294  1557  56  37  6  32  17 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号