EEWORLDEEWORLDEEWORLD

Part Number

Search

FLUKE-1730/BASIC

Description
datalogging & acquisition portable energy logger no probes
CategoryTopical application    Test and measurement   
File Size5MB,6 Pages
ManufacturerFluke
Websitehttps://www.fluke.com
Environmental Compliance
Download Datasheet Parametric Compare View All

FLUKE-1730/BASIC Overview

datalogging & acquisition portable energy logger no probes

FLUKE-1730/BASIC Parametric

Parameter NameAttribute value
ManufactureFluke
Product CategoryDatalogging & Acquisiti
RoHSYes
ProducHubs
TypeDatalogging
Display TypeLCD
Connection MethodUSB
InterfaceUSB
Current Rating120 A
Description/FunctiThree-Phase electrical energy logger, excludes current probes
Frequency69 Hz
Heigh2.2 i
Operating Temperature Range- 10 C to + 50 C
Power Consumpti50 VA
Resoluti16 bi
Safety RatingIEC 61010-1
Voltage Rating500 V
Unit Weigh4.785 kg
Three-Phase Electrical
Energy Logger
Fluke 1730
Technical Data
Energy logging is now within your reach—
discover where you’re wasting energy, optimize
your facility’s energy use and reduce your bill.
The new Fluke 1730 Three-Phase Electrical Energy logger
introduces a new simplicity to discovering sources of
electrical energy waste. Discover when and where
energy in your facility is being consumed; from the
service entrance to individual circuits. Profiling energy
usage across your facility helps you identify opportunities
for energy savings, and provides you with the data you
need to act on them. The new Energy Analyze software
package allows you to compare multiple data points over
time to build a complete picture of energy usage, which
is the first step to reduce the cost of your energy bill.
Key measurements:
voltage, current, power,
power factor and associated values enable
energy saving strategies to be implemented.
Bright, color touch screen:
perform conve-
nient in-the-field analysis and data checks
with full graphical display.
Comprehensive logging:
all measured values
are automatically logged and can be reviewed
during logging and before downloading for on-
the-go analysis. More than 20 separate logging
sessions can be stored on the instrument.
Optimized user interface:
quick, guided,
graphical setup ensures you’re capturing the
right data every time, and the intelligent veri-
fication function indicates correct connections
have been made, reducing user uncertainty.
Complete ‘in-the-field’ setup through the
front panel:
no need to return to the workshop
for download and setup or to take a computer
to the electrical panel.
Wide range power:
power instrument directly
from the measured circuit eliminating the
need to find a power outlet while allowing the
instrument to be secured safely inside electri-
cal panels.
Two USB ports:
one for PC connection and
another for fast, simple download to standard
USB thumb drives, or other USB devices.
Compact size:
designed to fit in tight spaces
and panels.
Highest safety rating in the industry:
600 V
CAT IV/1000 V CAT III rated for use at the ser-
vice entrance and downstream.
Optimized measurement accessories:
flat
voltage cable and thin flexible current probes
ensure easy installation even in tight spaces.
Battery life:
four-hour operating time (backup
time) per charge on lithium-ion battery.
Security:
safeguard against theft with a
Kensington lock.
All new, Energy Analyze application soft-
ware:
download, analyze and automated
reporting for a complete picture of energy
saving potential.

FLUKE-1730/BASIC Related Products

FLUKE-1730/BASIC FLUKE-1730/US
Description datalogging & acquisition portable energy logger no probes datalogging & acquisition portable energy logger US version
Differential pressure sensor
I would like to ask you guys, for the pressure difference or pressure sensor, is the accuracy index at high temperature definitely looser than that at normal temperature? Since I am a novice, I don't ...
lizhonghao008 Sensor
Seeking long-term technical cooperation with engineers developing single-chip computers for signal acquisition such as capacitance, resistance, and millivolt
[font=宋体][size=10.5pt]Seeking long-term technical cooperation with engineers developing capacitor, resistor, millivolt and other signal acquisition microcontrollers. If interested, please send an emai...
LUKEBS MCU
About TI DSP EDMA debugging
[size=3]In EDMA operation, a total of two parameter tables are used, one of which is maintained by the EDMA controller and the other is maintained by the user. The parameter table maintained by the ED...
Jacktang DSP and ARM Processors
Electric Vehicle Electric Drive Theory and Design (2nd Edition)
This book comprehensively introduces the composition and control methods of electric drive systems for electric vehicles. This book is divided into ten chapters, which describe the development of elec...
arui1999 Download Centre
Choosing the Right Digital Potentiometer for Your Design
...
gaoyang9992006 ADI Reference Circuit
430 development board support package BSP430
[size=4]MSPGCC's [color=#000000]maintainer Peter(pabigot)[/font][/align] recently completed the release of the MSP430 board support package. [/color][/size] [size=4][color=#000000]Generally, BSPs are ...
wstt Microcontroller MCU

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 157  622  2589  535  315  4  13  53  11  7 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号