EEWORLDEEWORLDEEWORLD

Part Number

Search

56.42.8.230.2350

Description
Electromechanical Relay, DPDT, AC/DC Output
CategoryMechanical and electronic products    relay   
File Size2MB,10 Pages
ManufacturerFINDER
Download Datasheet Parametric View All

56.42.8.230.2350 Overview

Electromechanical Relay, DPDT, AC/DC Output

56.42.8.230.2350 Parametric

Parameter NameAttribute value
Reach Compliance Codecompli
body width20.7 mm
body height36.8 mm
Body length or diameter27.7 mm
Coil operating voltage (AC)184 V
Coil resistance17000 Ω
Maximum coil voltage (AC)253 V
Nominal coil voltage230 V
Coil/Input Power TypeAC
Contact (AC) maximum rated R load20A@400VAC
Maximum contact current (AC)20 A
Maximum contact voltage (AC)400 V
Contact/Output Power TypeAC/DC
Dielectric strength between coil and contacts4000 Vrms
Dielectric strength between breaking contacts1000 Vrms
Electrical life100000 Cycle(s)
End contact materialSilver Cadmium Oxide
Number of terminals8
operating hours8 ms
PCB hole count8
physical size27.7mm x 20.7mm x 36.8mm
GuidelineCSA; IMQ; PCT; UL; VDE
Relay functionDPDT
release time3 ms
Terminal length0.0043 inch
Termination typeSOLDER
Base Number Matches1
56
56 Series - Miniature power relays 12 A
Features
Plug-in - 12 A Power relay, 2 & 4 pole
Flange mount option -
(Faston 187, 4.8x0.5 mm termination)
AC coils & DC coils
Lockable test button and mechanical flag indicator
Cadmium Free contacts (standard version)
Contact material options
96 series sockets
Coil EMC suppression
Accessories
European Patent
SERIES
56.32/56.34
56.32-0300
Plug-in / PCB Relays
1
2 or 4 pole changeover contact
Plug-in/Faston 187
2 pole normally open contact
(≥1.5 mm gap)
Plug-in/Faston 187
56.32
56.32-0300
56.34
* For 4 CO (4PDT) only.
F
OR
UL
RATINGS SEE
:
“General technical information” page
V
Contact specification
Contact configuration
Rated current/Maximum peak current
Rated load AC1
Rated load AC15 (230 V AC)
Single phase motor rating (230 V AC)
Breaking capacity DC1: 30/110/220 V
Minimum switching load
Standard contact material
Coil specification
Nominal voltage (U
N
)
Rated power AC/DC
Operating range
Holding voltage
Must drop-out voltage
Technical data
Mechanical life AC/DC
Electrical life at rated load AC1
Operate/release time
XI-2013, www.findernet.com
56.32
56.34
56.32-0300
2 CO (DPDT)
A
VA
VA
kW
A
12/20
250/400
3,000
700
0.55
4 CO (4PDT)
2NO (DPST-NO) -
≥1.5mm
gap
12/20
250/400
3,000
700
0.55
12/1/0.5
500 (10/5)
AgNi
Rated voltage/Maximum switching voltage V AC
12/0.5/0.25
500 (10/5)
AgNi
mW (V/mA)
V AC (50/60 Hz)
V DC
VA (50 Hz)/W
AC
DC
AC/DC
AC/DC
cycles
cycles
ms
V AC
°C
8/3
4
1.5/1
6 - 12 - 24 - 48 - 60 - 110 - 120 - 230 - 240 - 400*
6 - 12 - 24 - 48 - 60 - 110 - 125 - 220
2/1.3
(0.8…1.1)U
N
(0.8…1.1)U
N
(0.85…1.1)U
N
0.8 U
N
/0.6 U
N
0.2 U
N
/0.1 U
N
20 · 10
6
/50 · 10
6
100 · 10
3
10/4
5
1,000
–40…+70
RT I
1.5/—
(0.85…1.1)U
N
0.85 U
N
/—
0.2 U
N
/—
20 · 10
6
/—
100 · 10
3
8/4
4
2,000
–40…+70
RT I
Insulation between coil and contacts (1.2/50 µs) kV
Dielectric strength between open contacts
Ambient temperature range
Environmental protection
Approvals
(according to type)
Connect the display via wince smartphone usb
I have a project that requires an external display for a mobile phone, probably 10-15 inches, and I want to ask if there is a ready-made product. If not, is it feasible to develop a new product?...
jasonkiller Embedded System
If we can implement object-oriented programming with structures, then why do we need C++?
From EEWORLD cooperation group: 49900581...
秋水-剑圣 Embedded System
Temperature sensor in STM32
I'm using an STM32F103C8, and the datasheet says that sensors and VREFINT are only available on the main ADC peripheral. What does that mean?...
爱好汽车电子 stm32/stm8
Miscellaneous talks on rectification (Part 2)
[i=s] This post was last posted by maychang on 2016-2-26 15:13 Edit[/i][align=left][b][size=2]Except for very simple and crude loads such as DC motors, the rectifier circuits in electronic devices nee...
maychang Power technology
Help: Can FLASH write to any address for next access?
RT, I want to save 20 bytes of data in the program, and it will not be lost when the power is off. Can I write it directly into the FLASH, that is, I specify an address to write it in, and then read t...
自然的天意 stm32/stm8
Looking for 2 emergency lighting engineers~
:) First post "Help, everyone. Does anyone recommend a R&D engineer for emergency lights? Those who have worked on fire emergency lights and can independently develop all the technologies for fire eme...
Susanzhoull Industrial Control Electronics

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 914  467  2523  1382  1723  19  10  51  28  35 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号