BK/HLRGMF-1.6

Description
fuse holder fuseholder W/fuse
CategoryCircuit protection   
File Size49KB,2 Pages
ManufacturerBussmann (Eaton)
Download Datasheet Parametric Compare View All

BK/HLRGMF-1.6 Overview

fuse holder fuseholder W/fuse

BK/HLRGMF-1.6 Parametric

Parameter NameAttribute value
ManufactureCooper Bussm
Product CategoryFuse Holde
RoHSN
ProducFuse Holders
Current Rating12 A
Voltage Rating300 V
Number of Poles1
Mounting StylePanel
Shaft TypeNon Rejecting
ColBlack
IlluminatiNot Illuminated
PackagingBulk
Factory Pack Quantity500
Unit Weigh17.237 g
Bussmann
®
Specialty Fuse
Time-Delay, Non-Rejecting
GMF & GRF
GMF, GRF
& HLR
Dimensional Data
FUSE
0.63"
(15.9mm)
HLR
FUSE AND CARRIER
.850"
(21.59mm)
2.250"
(57.15mm)
Catalog Symbols:
GMF, GRF & HLR
Time-Delay
Non-Rejection Style Fuse
GMF
Amperes
Volts AC
⁄Ω•-6⁄Ω¢,10
300
Line Lead
GRF
7-10
300
.720"
(18.29mm)
.850"
(21.59mm)
C
L
MOUNTING HOLE
Load Lead
.410"
(10.41mm)
Interrupting Rating:
10,000 Amperes
Agency Information:
GMF and GRF Fuse:
UL Listed, Std. 248-14, Guide JDYX, File E19180
CSA Certified, C22.2 No. 248.14, Class 1422-01, File 53787
HLR Fuseholder:
UL Recognized, 12A, 300 Vac, Guide IZLT2, File E14853
CSA Certified, 12A, 300 Vac, Class 6225-01, File 47235
HLR-2A:
UL Recognized, 15A, 300 Vac, Guide IZLT2, File E14853
CSA Certified, 15A, 300 Vac, Class 6225-01, File 47235
Electrical Ratings for Type GMF and GRF Fuses and
Non-Rejection Style Carriers
Fuse
GMF-‹Ω¡º
GMF-⁄Ω™
GMF-flꭧ
GMF-°Ω¡º
GMF-1
GMF-1⁄Ω¢
GMF-1flꭧ
GMF-2
GMF-2⁄Ω™
GMF-2°Ω¡º
Carrier
HLR
HLR
HLR
HLR
HLR
HLR
HLR
HLR
HLR
HLR
Fuse
GMF-3
GMF-3¤Ω¡º
GMF-4
GMF-5
GMF-6⁄Ω¢
GRF-7
GRF-8
GRF-10
GMF-10
Carrier
HLR
HLR
HLR
HLR
HLR
HLR
HLR
HLR
HLR
.870"
(22.10mm)
.635"
(16.13mm)
.740"
(18.80mm)
Knockout Hole
.255"
(6.48mm)
Keyhole Punch
General Information:
• HLR carrier comes with
6∑
of #18 red insulated solid copper
wire attached to the line side.
• Customer inserts a #18 insulated solid copper wire into load
side receptacle.
• Order part number HLR-2A to obtain
6∑
of #18 black insulat-
ed solid copper wire pre-installed in a load side receptacle.
• Order part number HLR-2L to obtain
6∑
of #18 black insulated
solid copper wire packaged loose (un-installed).
• An alternative to the HLR fuseholder is the A fuseholder. The
A fuseholder comes WITHOUT leads. The customer inserts
#18 insulated solid copper wire into the line side receptacle as
well as into the load side receptacle. It has the same body
dimensions, utilizes the same mounting hole, and takes the
same mounting clips as the HLR. The A fuseholder is UL
Recognized, 10A, 300Vac, Guide IZLT2, File E14853 and CSA
Certified, 10A, 300Vac, Class 6225-01, File 47235.
• Fuse and knob are an integral one-piece unit. There are no
replacement knobs (caps).
• Units can be panel mounted with a separate steel clip. For the
knockout hole (see above), choose #BK/A-104. For the key-
hole punch type hole, choose #6374 for panels .043” to .062”
thick, or #4909 for panels .030” to .042” thick.
• Do not put tension on line (rear) terminal of fuseholder.
CE logo denotes compliance with European Union Low Voltage Directive
(50-1000 Vac, 75-1500 Vdc). Refer to Data Sheet: 8002 or contact Bussmann
Application Engineering at 636-527-1270 for more information.
5-22-02
SB02233
Form No. GMF, GRF & HLR
Page 1 of 2
Data Sheet: 2031

BK/HLRGMF-1.6 Related Products

BK/HLRGMF-1.6 GMF-5
Description fuse holder fuseholder W/fuse specialty fuses 300vac time delay non-rejecting
Manufacture Cooper Bussm Cooper Bussm
Product Category Fuse Holde Specialty Fuses
RoHS N N
Produc Fuse Holders Specialty Fuses
Current Rating 12 A 5 A
Mounting Style Panel Cable
Packaging Bulk Bulk
Factory Pack Quantity 500 5
Unit Weigh 17.237 g 5.897 g
The computer shows that the program has been downloaded successfully, but the board still runs the original program
Please help me, thanks. What is the problem (O_O)? I feel desperate orz...
乐乐乐乐舒瑶 stm32/stm8
W77E58 Header File
Help: I downloaded a header file for W77E58, but I don't know how to use it. Some people on the Internet said that I can just copy it into the project file. Does this project file refer to the window ...
szwangwei Embedded System
[Evaluation of EC-01F-Kit, the NB-IoT development board of Anxinke] A thermometer based on STM32F103C8T6 connected to MQTT network
[i=s]This post was last edited by lugl4313820 on 2021-12-19 22:49[/i]Yesterday, I realized the data publishing on MQTT. Today, I realized that stm32F103C8T6 uses DS18B20 to collect temperature, publis...
lugl4313820 RF/Wirelessly
Power supply dynamic response test, what kind of waveform is considered qualified?
Dynamic response generally refers to the response of the output of a control system from the initial state to the final state under the action of a typical input signal. When a unit step input x(t) is...
木犯001号 Power technology
Does anyone have the schematic diagram of the IPM driver module? Please share it! Thank you very much!
Does anyone have the schematic diagram of the IPM driver module? Please share it! Thank you very much!...
1540260972 Power technology
Please help design a control circuit for elevator operation
A four-story building with two elevators: Elevator 1 and Elevator 2Requirements: 1. When a person on a certain floor presses the "Call" command, the elevator closer to him arrives;2. If the two elevat...
jincheng520 FPGA/CPLD

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2353  849  2150  140  1669  48  18  44  3  34 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号