FRN-R-25

Description
industrial & electrical fuses 250v 25a dual elemtent time delay
CategoryCircuit protection   
File Size324KB,2 Pages
ManufacturerBussmann (Eaton)
Download Datasheet Parametric Compare View All

FRN-R-25 Online Shopping

Suppliers Part Number Price MOQ In stock  
FRN-R-25 - - View Buy Now

FRN-R-25 Overview

industrial & electrical fuses 250v 25a dual elemtent time delay

FRN-R-25 Parametric

Parameter NameAttribute value
ManufactureCooper Bussm
Product CategoryIndustrial & Electrical Fuses
RoHSN
Body StyleCartridge Fuses
Current Rating25 A
Voltage Rating AC250 V
Voltage Rating DC125 V
Mounting StyleHolde
Termination StyleCli
Fuse TypeTime Delay / Slow Blow
Fuse Size / GrouClass RK5
Indicator StyleWithout Indic
Dimensions2 in L x 0.56 in D
Case Diamete0.56 i
Case Length2 i
Interrupt Rating200 kA
PackagingBulk
ProducIndustrial Power Fuses
Factory Pack Quantity10
TypeGeneral
Unit Weigh22.680 g
Fusetron
®
Dual-Element, Time-Delay Fuses
Class RK5 - 250 Volt
Dimensional Data
2"
(± 0.31)
0.56" (± 0.008)
1
/
10
A
FRN-R
1
10
-60A
to 30A
3"
(± 0.31)
0.81" (± 0.008)
35A to 60A
Catalog Symbol:
FRN-R
Current-Limiting
Dual-Element, Time-Delay – 10 seconds (minimum) at 500%
rated current (8 seconds for 0-30A sizes)
Ampere Rating:
1
10
to 60 Amperes
Voltage Rating:
250Vac (or less)
Interrupting Rating:
200,000A RMS Sym.
DC Ratings: 20,000 AIC @ 125Vdc
Agency Information:
UL Listed, Std. 248-12, Class RK-5, Guide JDDZ, File E4273
CSA Certified, C22.2 No. 248.12, Class 1422-01, File 53787
Catalog Numbers
FRN-R-
1
10
FRN-R- ⁄
8
1
FRN-R-1
8
10
FRN-R-2
FRN-R-2 ⁄
4
1
1
8
FRN-R-8
FRN-R-9
FRN-R-10
FRN-R-12
FRN-R-15
FRN-R-17
1
2
FRN-R-20
FRN-R-25
FRN-R-30
FRN-R-35
FRN-R-40
FRN-R-45
FRN-R-50
FRN-R-60
FRN-R- ⁄
100
15
2
1
3
FRN-R- ⁄
10
FRN-R- ⁄
4
FRN-R- ⁄
10
FRN-R-
4
10
FRN-R- ⁄
2
1
6
FRN-R-2 ⁄
2
FRN-R-2 ⁄
10
FRN-R-3
FRN-R-3
2
10
FRN-R-3 ⁄
2
1
General Information:
• Provides motor overload, ground fault and short-circuit
protection.
• Helps protect motors against burnout from overloads.
• Helps protect motors against burnout from single phasing
on three phase systems.
• Simplifies and improves blackout prevention (selective
coordination).
• Dual-element fuses can be applied in circuits subject
to temporary motor overloads and surge currents to
provide both high performance short-circuit and
overload protection.
• The overload element provides protection against low level
overcurrent of overloads and will hold an overload which is
five times greater than the ampere rating of the fuse for a
minimum of ten seconds.
Fuse Reducers For Class R Fuses
Equipment
Fuse Clips
60A
100A
200A
Desired Fuse
(Case) Size
30A
30A
60A
60A
Catalog Number
(Pairs) 250V
No. 263-R
No. 213-R
No. 216-R
No. 226-R
FRN-R- ⁄
10
FRN-R-
8
10
FRN-R-1
FRN-R-1
1
8
FRN-R-1 ⁄
4
1
4
1
6
FRN-R-4
FRN-R-4
1
2
FRN-R-5
FRN-R-5
6
10
FRN-R-6
FRN-R-6 ⁄
4
1
FRN-R-1 ⁄
10
FRN-R-1 ⁄
2
FRN-R-1 ⁄
10
FRN-R-7
FRN-R-7 ⁄
2
1
Fuseblocks for Class R Fuses
(Clip Retaining Spring Standard, Suffix “R”)
See Data Sheet 1110
Basic
Catalog
Poles Number
1
R25030-1
2
3
1
2
3
R25030-2
R25030-3
R25060-1
R25060-2
R25060-3
Terminal
Screw w/
Pres.
Plate
SR
PR
SR
SR
SR
SR
SR
PR
PR
Type (Suffix No.)
1
2
˝
Box Lug w/
Clip
Quick-
CU only Connect
CR
COR
QR
CR
CR
CR
CR
CR
COR
COR
Carton Quantity and Weight
Ampere
Ratings
0–15
17.5–30
35–60
*Weight per carton.
Carton
Qty.
10
10
10
Weight*
Lbs.
0.40
0.50
1.00
Kg.
0.181
0.227
0.453
Amps
1
10
to
30
31
to
60
10-08 BU-SB08353
Page 1 of 2
Data Sheet 1019

FRN-R-25 Related Products

FRN-R-25 FRN-R-12 FRN-R-3-1/2 FRN-R-4-1/2 FRN-R-1-1/4 FRN-R-45 FRN-R-200
Description industrial & electrical fuses 250v 25a dual elemtent time delay industrial & electrical fuses 250v 12a dual elemtent time delay industrial & electrical fuses 250v 3.5A dual elemtent time delay industrial & electrical fuses 250v 4.5A dual elemtent time delay industrial & electrical fuses 250v 1.25a dual elemtent time delay industrial & electrical fuses 250v 45a dual elemtent time delay industrial & electrical fuses 250v 200a dual elemtent time delay
Manufacture Cooper Bussm Cooper Bussm Cooper Bussm Cooper Bussm Cooper Bussm Cooper Bussm Cooper Bussm
Product Category Industrial & Electrical Fuses Industrial & Electrical Fuses Industrial & Electrical Fuses Industrial & Electrical Fuses Industrial & Electrical Fuses Industrial & Electrical Fuses Industrial & Electrical Fuses
RoHS N N N N N N N
Body Style Cartridge Fuses Cartridge Fuses Cartridge Fuses Cartridge Fuses Cartridge Fuses Cartridge Fuses Cartridge Blade Fuses
Current Rating 25 A 12 A 3.5 A 4.5 A 1.25 A 45 A 200 A
Voltage Rating AC 250 V 250 V 250 V 250 V 250 V 250 V 250 V
Voltage Rating DC 125 V 125 V 125 V 125 V 125 V 125 V 125 V
Mounting Style Holde Holde Holde Holde Holde Holde Holde
Termination Style Cli Cli Cli Cli Cli Cli Knife Blade
Fuse Type Time Delay / Slow Blow Time Delay / Slow Blow Time Delay / Slow Blow Time Delay / Slow Blow Time Delay / Slow Blow Time Delay / Slow Blow Time Delay / Slow Blow
Fuse Size / Grou Class RK5 Class RK5 Class RK5 Class RK5 Class RK5 Class RK5 Class RK5
Indicator Style Without Indic Without Indic Without Indic Without Indic Without Indic Without Indic Without Indic
Dimensions 2 in L x 0.56 in D 2 in L x 0.56 in D 2 in L x 0.56 in D 2 in L x 0.56 in D 2 in L x 0.56 in D 3 in L x 0.81 in D 3 in L x 13/16 in W
Case Length 2 i 2 i 2 i 2 i 2 i 3 i 3 i
Interrupt Rating 200 kA 200 kA 200 kA 200 kA 200 kA 200 kA 200 kA
Packaging Bulk Bulk Bulk Bulk Bulk Bulk Bulk
Produc Industrial Power Fuses Industrial Power Fuses Industrial Power Fuses Industrial Power Fuses Industrial Power Fuses Industrial Power Fuses Industrial Power Fuses
Type General General General General General General General
Unit Weigh 22.680 g 20.412 g 22.226 g 25 g 18.144 g 56.699 g 362.874 g
Case Diamete 0.56 i 0.56 i 0.56 i 0.56 i 0.56 i 0.81 i -
How to fill a sector in protel PCB diagram
The circle is divided into 18 sectors. Now I need to fill some sectors with black or red. How can I do it? It is difficult to use place fill. The key is that this sector needs to be filled with black....
swji Embedded System
Multi-node temperature acquisition system
The MSP430 microcontroller is used as the main controller to control multiple DS18B20 to collect temperature. After processing according to a certain protocol, it is sent to the handheld terminal base...
BruceLone Wireless Connectivity
Question about negative feedback resistors for op amps
This is the operational amplifier acquisition circuit of my experiment. There is also an embedded circuit at the input end, which is not drawn here. The problem is that the collected data is very unst...
hanwenli123 Analog electronics
Electronic racing camera
Since there was a camera on the list for this electronic competition, the teacher asked me to buy a camera. Before, considering that the maximum main frequency of 430F5529 was only 25M, I chose a seri...
好可爱的小多C Electronics Design Contest
LM3S9B92 MCU LCD displays pictures in SD card
What functions should be used to display pictures in SD card on LCD of LM3S9B92 microcontroller? How to write the program?...
素商 Microcontroller MCU
Bluetooth related issues
I have a Bluetooth module with a USB interface. I plug it into my development board, and then use the "Bluetooth Settings" under the "Control Panel" to search for other Bluetooth devices. This means t...
liso Embedded System

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1690  1757  2403  1215  1328  35  36  49  25  27 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号