HGN-365A02W-16-1ES

Description
Mains Power Connector, 2A, 115/250VAC, Male, Socket
CategoryThe connector    The connector   
File Size475KB,3 Pages
ManufacturerPower Dynamics, Inc.
Websitehttp://www.powerdynamics.com/
Environmental Compliance
Download Datasheet Parametric View All

HGN-365A02W-16-1ES Overview

Mains Power Connector, 2A, 115/250VAC, Male, Socket

HGN-365A02W-16-1ES Parametric

Parameter NameAttribute value
Is it lead-free?Lead free
Is it Rohs certified?conform to
MakerPower Dynamics, Inc.
Reach Compliance Codecompliant
Other featuresSTANDARDS: IEC 60320; UL; VDE
Body/casing typeSOCKET
Connector typeMAINS POWER CONNECTOR
Contact to complete cooperationNOT SPECIFIED
Contact point genderMALE
Contact materialNOT SPECIFIED
Coupling typeSNAP
DIN complianceNO
IEC complianceYES
MIL complianceNO
Power Connector Ratings2A, 115/250VAC
Manufacturer's serial numberHGN-365A
Installation typePANEL
OptionsGENERAL PURPOSE
Total number of contacts3
Base Number Matches1
HGN-365A
IEC 60320 INLET SOCKET WITH SINGLE OR DOUBLE FUSE HOLDER,
SNAP-IN OR FLANGE MOUNT
MECHANICAL DIMENSIONS
(Unit: mm)
SNAP-IN
30.8
28.3
28.5
31.0
33.0
35.0
32.3
Use only with a 250V Fuse
SUGGESTED PANEL CUTOUT
(MOUNTING FROM FRONT)
THICKNESS OF PANEL IS FROM
1.00mm to 1.6mm
FEATURES
The HGN-365A filter series offers a wide variety of options
with a current rating up to 10A, 250VAC. This power entry
module offers industry standard 5 x 20mm fuse/s with IEC
connector. This series offers an option of having a single or
double fuse in the same package. These filters are also used
for health care equipment and offer extremely low leakage
current to comply with UL544 & 2602.
A Ground Choke can be added to enhance the grounding
ability of the circuit. A bleeder resistor can also be added to
prevent excessive voltages from developing across the filter
capacitors when there is no load.
2x
6
33.0
Use only with a 250V Fuse
42.6
48.5
(58.4)
6.3
27.8
31.0
FLANGE MOUNT
28.3
36.0
28.0 Max
31.0
APPLICATIONS
Computer & networking equipment, Measuring & control
equipment, Data processing equipment, laboratory instruments,
Switching power supplies, other electronic equipment.
2x
3.6
32.4 Typ.
2x
3.6
RECOMMENDED
PANEL CUTOUT
(MOUNTING FROM FRONT)
36.0
44.0
TECHNICAL DATA
Rated Voltage: 115/250VAC
Rated Current: 1A, 2A, 3A, 4A, 6A, 8A, 10A
Power Line Frequency: 50/60Hz
Max. Leakage Current each
Line to Ground:
@ 115VAC 60Hz: 0.5mA
@ 250VAC 50Hz: 1.0mA
@ 115VAC 60Hz: 2
µ
A*
@ 250VAC 50Hz: 5
µ
A*
Hipot Rating (one minute)
Line to Ground: 2250VDC
Line to Line: 1450VDC
Temperature Range: -25C to +85C
* Medical application
Panel Thickness 1mm to 1.6mm
(58.4)
48.5
42.6
6.3
27.8
31.0
Specifications subject to change without notice. Dimensions (mm). See Appendix A for
recommended power cord. See PDI full line catalog for detailed specifications on power cords.
70
145 Algonquin Parkway, Whippany, NJ 07981 • 973-560-0019 • FAX: 973-560-0076
e-mail: filtersales@powerdynamics.com •
www.powerdynamics.com
Headhunting position——Barcode handheld terminal development engineer
Barcode Handheld Terminal Development Engineers 1. 2 persons, college degree or above; 2. Familiar with manufacturing logistics business and barcode/RFID technology, and experience in warehouse and pr...
tianquan Embedded System
MFC requires WINVER to be #defined to 0x0400 or greater
When the project was created, it was wm5.0. Later, another simulator was selected. When compiling, "MFC requires WINVER to be #defined to 0x0400 or greater" appeared. How should I solve it?...
250200729 Embedded System
【TI's First Low Power Design Competition】Sacq's Wolverine (2): Reinstalling IAR
(1) Do I really need to upgrade the IDE? When I opened the box of the Wolverine development board, the first thing I saw was a yellow project label - a reminder to update to the latest version of the ...
sacq Microcontroller MCU
Application of ADSL broadband access technology in Korean communications1
I. Overview The main reason why Korea Telecom launched ADSL business was due to fierce market competition. Since telecommunication business was completely liberalized, in addition to Korea Telecom, ma...
songbo RF/Wirelessly
Questions about option byte
The chip is RL78G13 Development environment CS+ I used the code generator. After generating the code, I could not find the code related to the option byte. Where did the code generator put the code re...
bpshui Renesas Electronics MCUs
LaunchPad does not work
I have a used LaunchPad. When I plugged it into the computer for the first time, LED0 flashed once and then went out. No other LEDs were on. I don't know what happened. The computer didn't respond at ...
长毛小兔 Microcontroller MCU

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1405  352  16  1869  2735  29  8  1  38  56 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号