EEWORLDEEWORLDEEWORLD

Part Number

Search

LES25A48-1V2RE

Description
conv DC/DC 48v 25a 1.2vout 100w
Categorysemiconductor    Power management   
File Size103KB,3 Pages
ManufacturerArtesyn
Websitehttp://www.artesyn.com
Download Datasheet Parametric View All

LES25A48-1V2RE Overview

conv DC/DC 48v 25a 1.2vout 100w

LES25A48-1V2RE Parametric

Parameter NameAttribute value
Datasheets
Eighth Brick Series
Standard Package64
CategoryPower Supplies - Board Mou
FamilyDC DC Converters
PackagingTray
TypeIsolated Module
Number of Outputs1
Voltage - Input (Min)36V
Voltage - Input (Max)75V
Voltage - Output 11.2V
Voltage - Output 2-
Voltage - Output 3-
Current - Output (Max)25A
Power (Watts) - Manufacture Series30W
Voltage - Isolati2.25kV (2250V)
FeaturesRemote On/Off, OCP, OTP, OVP, SCP, UVLO
Mounting TypeThrough Hole
Package / Case8-DIP Module, 1/8 Brick
Size / Dimensi2.30" L x 0.90" W x 0.19" H (58.4mm x 22.9mm x 4.8mm)
Operating Temperature-40°C ~ 85°C
Efficiency88%
Power (Watts) - Max30W
Other Names393-1120
Eighth-Brick Series
Single output
DC/DC CONVERTERS
High Current, High Efficiency, Low Profile
NEW Product
1
Ultra-high efficiency topology
Industry standard eighth brick footprint (identical to quarter-brick pinout)
Low profile through-hole version
Low profile with 38% space savings over other quarter-brick brick converters
Wide ambient temperature range, -40ºC to +85ºC
80% to 110% output trim
Monotonic start-up in normal and prebiased loads
Basic insulation system
Overvoltage and overtemperature protection
Secondary side control, no optocouplers,
fast transient response
100V, 100ms input voltage transient rated
This is a new high efficiency, open-frame, low profile, single board, isolated DC/DC
converter series in an industry standard eight-brick footprint that provides up to 100W of
output power. The series delivers very high output current at low voltages, and excellent
useable power for today’s high performance applications. The series features an input
voltage range of 36 to 75VDC and is available with output voltages of 1.2V, 1.5V 1.8V, 2.5V,
3.3V and 5.0V. The output voltage is adjustable from 80% to 110% of the nominal value. The
series also has a remote ON/OFF capability. Over-current, over-voltage and over-temperature
protection features are included as standard. Full international safety approval including
EN60950 VDE and UL/cUL60950, reduces compliance costs and time to market.
All specifications are typical at nominal input, full load at 25°C ambient unless otherwise stated
TÜV
2 YEAR WARRANTY
SPECIFICATIONS
OUTPUT SPECIFICATIONS
Voltage adjustability
Minimum load
Overshoot
Undershoot
Transient response
(See Note 1)
INPUT SPECIFICATIONS
Input voltage range
Input current
48V nominal
No load
Remote OFF
36 to 75VDC
50mA
5mA
Open collector ref to -input
Open circuit or >2.4VDC
<0.4VDC
35.5V (typ.)
33.5V (typ.)
15ms (typ.)
15ms (typ.)
At turn-on and turn-off
80% to 110%
0%
None
None
60mV to 120mV typ. deviation
20µs recovery
EMC CHARACTERISTICS
Immunity:
ESD air enclosure
Radiated field enclosure
Conducted
Input transients
EN61000-4-2 8kV/6kV (O/P within spec.)
EN61000-4-3 10V/m (O/P within spec.)
EN61000-4-6 10V
(O/P within spec.)
100V, 100ms
GENERAL SPECIFICATIONS
Basic insulation
Switching frequency
Approvals and
standards
Material flammability
Weight
MTBF
Input/output
Fixed
(See Note 3)
2250VDC
480kHz
EN60950 VDE
UL/cUL 60950
UL94V-0
21g (0.73oz)
Telcordia Tech SR-332 4,034,120 hours
Active high remote ON/OFF
Logic compatibility
ON
OFF
Undervoltage lockout
Start-up time
(See Note 2)
Power up
Power down
ENVIRONMENTAL SPECIFICATIONS
Thermal performance
Operating ambient.
temperature
Non-operating
-40°C to +85°C
-55°C to +125°C
Power up
Remote ON/OFF
PROTECTION
Short-circuit
Over-voltage
Thermal
Continuous
Non-latching
125ºC hot spot temperature with
automatic recovery
International Safety Standard Approvals
UL/cUL CAN/CSA 22.2 No. 60950-00 : UL 60950
File No. E135734
VDE Certificate No. 40005017
CB Report and Certificate to IEC60950, Certificate No. DE1-19783
File Name: eighth_brick.pdf Rev (05): 21 Jun 2004
EEWORLD University - 5 Tips for Quickly Setting Up an Oscilloscope
5 Tips for Quickly Setting Up an Oscilloscope : https://training.eeworld.com.cn/course/4775...
量子阱 Test/Measurement
The problem with nandfalsh
I have a basic question. I am using a 2440 board. I first download Uboot to NorFalsh through jtag, then download Eboot and NK to NandFalsh through Uboot, and then start running from NandFalsh. 1. Can ...
linyis Embedded System
G2553 Serial Port Help
I use the G2553 serial port process, the sending data can enter the receiving interrupt, but mask TXBUF = RXBUF, assign the value in the receiving register to a variable, it can only enter the interru...
小粮zz Microcontroller MCU
Internet Management
State Council Information Office: New Internet technologies cannot be independent of social management 2006-7-7The head of the Internet Bureau of China's State Council Information Office recently stat...
ehk RF/Wirelessly
Automobile Group Subsidiary Recruitment of Car Audio Hardware Engineer/Wince Software Engineer
Beijing Penghao Jiye Technology Development Co., Ltd. is a wholly-owned subsidiary of Beijing Automotive Group, with a registered capital of RMB 22.12 million. It has a team of professionals from famo...
celtic Recruitment
Why does the 315/433M transceiver module receive a low level when the transmitter is at a high level?
Why does the 315/433M transceiver module receive a low level when the transmitter is high? It is easy to do phase inversion at the receiver, but is there any special reason for using the mechanism of ...
超级野狗 RF/Wirelessly

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1716  1634  705  388  2664  35  33  15  8  54 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号