EEWORLDEEWORLDEEWORLD

Part Number

Search

AST-FR43/13015/226-0

Description
AST-FR43/13015/226-0
CategoryAnalog mixed-signal IC    The signal circuit   
File Size27KB,2 Pages
ManufacturerTE Connectivity
Websitehttp://www.te.com
Download Datasheet Parametric View All

AST-FR43/13015/226-0 Overview

AST-FR43/13015/226-0

AST-FR43/13015/226-0 Parametric

Parameter NameAttribute value
MakerTE Connectivity
package instruction,
Reach Compliance Codeunknow
Base Number Matches1
SST and AST
Self-sealing heat-shrinkable tubing
Fax-on-Demand:
(800) 260-9099
(650) 361-6523
Before ordering check with
factory for most current data.
FAX ID
2290
Description
Data sheet
Applications
SST and AST provide a simple, positive splice-sealing method
that offers protection under adverse environmental conditions.
Tubing supplied with standard sealant provides water sealing
and environmental protection in wet or underground applica-
tions. The thermoplastic adhesive not only seals, but also pro-
vides mechanical strain relief. The polymer tubing has excellent
insulating, abrasion-resisting, and strain-relief properties.
Features/Benefits
Strain relief.
Waterproofing.
Thick-wall insulation and abrasion-protection.
No need for greases, tape, or epoxy.
Expansion ratios as high as 3:1.
Availability in flame-retardant material.
AST-FR has the following agency approvals:
—ABS (American Bureau of Shipping)
—DNV (Det Norske Veritas)
—Lloyd’s (Lloyd’s Register of Shipping)
Installation
Minimum shrink temperature: 90°C
Minimum full recovery temperature: 121°C
Specifications/Approvals
®
®
Series
SST
SST-FR
UL
CSA
Military
MIL-DTL-23053/15A*,
Class 1 and Class 2
Industry
AST-FR
AST
*Formerly MIL-I-23053/I5A.
ASTM D 685, nonburning
ASTM D 2863, oxygen index
IPCEA S-19-81, cable insulation and jackets
IEEE-383 Section 2.5 massive flame vertical tray
ABS, DNV, Lloyd’s Register
RW 2017
RW 2011
Raychem
Nemosyne 90
Nemosyne FR
Product Dimensions
(inches)
Mil-Spec
approved
part number
SST*-03
SST*-04
SST*-07M
SST*-07
SST*-11M
SST*-11
SST*-13M
SST*-13
SST*-15M
SST*-15
SST*-17M
SST*-17
SST*-20M
SST*-20
SST*-27
SST*-30
SST*-40
SST*-45
In
Agency
approved
part number
AST 8/3
AST 10/4
AST 19/6(M)
AST 19/6
AST 33/10(M)
AST 33/10
AST 43/13(M)
AST 43/13
AST 51/19(M)
AST 51/19
AST 69/23
AST 76/32
AST 114/45
Standard
nominal
length
6
6
6, 9, 12
6, 9, 12
6, 9, 12
6, 9, 12
6, 9, 12
6, 9, 12
6, 9, 12
6, 9, 12
6, 9, 12
6, 9, 12
6, 9, 12
6, 9, 12
12, 18, 24
12, 18, 24
12, 18, 24
12, 18, 24
Internal diameter
Minimum
Maximum
expanded recovered
0.300
.100
0.400
.150
0.750
.220
0.750
.220
1.100
.375
1.100
.375
1.300
.375
1.300
.375
1.500
.500
1.500
.500
1.700
.500
1.700
.500
2.000
.750
2.000
.750
2.700
.900
3.000
1.250
4.000
1.750
4.500
1.750
Wall thickness (nominal)
Expanded
.025
.025
.020
.030
.030
.040
.025
.035
.035
.050
.030
.045
.040
.050
.050
.050
.050
.050
Recovered
††
.060
.060
.060
.095
.105
.120
.105
.120
.120
.140
.120
.140
.120
.155
.155
.155
.155
.155
Recommended cable
range for 600-volt cable
#18 through #14 AWG
#14 through #10 AWG
#8 through #1 AWG
#8 through #1 AWG
#2 through #4/0 AWG
#2 through #4/0 AWG
#2 through #4/0 AWG
#2 through #4/0 AWG
#2/0 AWG through 500 MCM
#2/0 AWG through 500 MCM
#2/0 AWG through 500 MCM
#2/0 AWG through 500 MCM
#350 MCM through 1000 MCM
#350 MCM through 1000 MCM
#500 MCM through 1250 MCM
#900 MCM through 1500 MCM
#1500 MCM through 2500 MCM
#1500 MCM through 2500 MCM
place of asterisk* substitute length of tubing to be ordered. For example, SST*-11, as the third column indicates, comes in 6-, 9-, and 12-inch lengths, so 9-inch SST tubing would be
SST 9-11. The suffix M = medium-wall tubing.
††
Wall thickness will be less if tubing recovery is restricted during shrinkage.
3-42
Tubing
R
Users should independently evaluate the suitability of the product for their application.
How to turn off the power when disabling the network card and turn on the power when enabling it?
As the title says: The platform is PXA270+CE5.0. Since the network card is rarely used, how can I turn off the power when disabling the network card and turn on the power when enabling it? What operat...
z9x386 Embedded System
The next industrial revolution relies on wireless connectivity
Industry 4.0 is considered the next chapter in the evolution of smart manufacturing. Powered by the Internet of Things (IoT), these technologies can now provide real-time connectivity to control and g...
兰博 RF/Wirelessly
Playing with Zynq Serial 20: Modular Design Based on FPGA
1 Overview of Modular DesignModular design is a very important technique in FPGA design. It can make the division of labor and collaboration, simulation testing of a large design easier, and code main...
ove学习使我快乐 FPGA/CPLD
The latest LAYOUT CC1101 transceiver module, small size,
CC1101+PA+LNA is a wireless transceiver module that integrates FSK/ASK/OOK/MSK modulation. CC1101+PA+LNA RF transceiver module is a multi-channel radio product with the lowest system cost in the indus...
zhaofaohua Microcontroller MCU
Regarding the design method of a frequency meter, urgent!
As I didn't explain it clearly last time, the post got buried. I'll post it again. I hope experts can help me. The attachment is a design idea, in which the 8MHz crystal is divided down to 0.8Hz as th...
king0529 MCU
ProtelDXP2004SP2 most classic tutorial
The most classic tutorial of ProtelDXP2004SP2, I hope you like it...
szjhtx PCB Design

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1025  1001  2249  1613  1255  21  46  33  26  43 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号