177-740-5-130GP6K5-18SDG

Description
Cable Assembly, 26AWG,
CategoryThe connector    Connector bracket   
File Size858KB,5 Pages
ManufacturerGlenair
Websitehttp://www.glenair.com/
Environmental Compliance
Download Datasheet Parametric View All

177-740-5-130GP6K5-18SDG Overview

Cable Assembly, 26AWG,

177-740-5-130GP6K5-18SDG Parametric

Parameter NameAttribute value
Is it Rohs certified?conform to
Objectid7005082943
Reach Compliance Codecompliant
Country Of OriginUSA
YTEOL8.23
Other featuresSTANDARD: MIL-DTL-83513
CertificationMIL
Conductor surface treatmentSILVER
conductor materialCOPPER
ConnectorSide1MICRO-D MALE
ConnectorSide2MICRO-D MALE
Connector bracket typeCABLE ASSEMBLY
structureSTRANDED
Cross-sectional area0.129 mm2
DIN complianceNO
IEC complianceNO
insulator materialPOLYTETRAFLUOROETHYLENE
Jacket materialETHYLENE-CHLOROTRIFLUOROETHYLENE
length0.466 mm
MIL complianceYES
Number of conductors130
Maximum operating temperature150 °C
Minimum operating temperature-55 °C
Rated current3 A
Rated voltage150 V
resistance0.125 Ω
shieldNO
stay19X38
Wire gauge26 AWG
Wire and Cable NamesFLEXIBLE CORD AND FIXTURE WIRE
B
SHIELDING EFFECTIVENESS (Db)
1.00E+04
1.00E+05
1.00E+06
1.00E+07
1.00E+08
1.00E+09
SHIELDING EFFECTIVENESS (Db)
Micro-D Harness
EMI Performance with Ground Spring
100
90
80
70
60
50
40
30
20
10
0
1.00E+03
MWDM Micro-D
Shielded Cable Assembly
Single-Ended or Double-Ended–These
easy-to-order cable
assemblies eliminate the need for expensive assembly labor. 100%
tested and ready for use.
Now With Twisted Pairs–No
need to create a procurement
specification for Micro-D cables with twisted pairs. Glenair 177-740
cables are furnished with a full complement of white/blue twisted
pair wires.
Integral Shield Termination–The
connector shell has a platform
to accept Band-It shield termination bands. The cable shield braid is
attached directly to the connector.
Save Labor, Reduce Weight and Improve EMI Shielding
with Glenair’s Micro-D Shielded Cable Assemblies
Aerospace electronics systems require higher and higher levels of protection from radiated emissions. Glenair’s
fully shielded Micro-D cable assemblies meet this need. The cable shield is attached directly onto the one-
piece connector shell and secured with a stainless steel
Band-Master™ ATS
clamp. These pre-wired, 100% tested
assemblies meet the requirements of MIL-DTL-83513. An optional ground spring on the pin connector assures low
shell-to-shell resistance. Available with a variety of wire types and shields, Micro-D shielded assemblies can be
ordered in any length, either single-ended or “back-to-back”.
Ground Spring and EMI Shielding Effectiveness
A gold-plated stainless steel ground spring on the pin connector mating
face offers substantial improvement in EMI protection. The graphs
compare identical connectors tested with and without ground springs.
EMI Performance without Ground Spring
100
90
80
70
60
50
40
30
20
10
0
1.00E+03
1.00E+04
1.00E+05
1.00E+06
1.00E+07
1.00E+08
1.00E+09
frequency (Hz)
frequency (Hz)
© 2013 Glenair, Inc.
High Performance Micro-D Connectors and Cables
U.S. CAGE Code 06324
Printed in U.S.A.
GLENAIR, INC.
1211 AIR WAY
GLENDALE, CA 91201-2497
818-247-6000
FAX 818-500-9912
www.glenair.com
B-14
E-Mail: sales@glenair.com
msp430F5418ADC12 has a large error when used
When I use msp430F5418ADC12, I set P6.3 as the input port. After inserting a voltage, I observed that the conversion value changed greatly and was basically unrelated to the input value. The following...
zhangzy2517 Microcontroller MCU
I'm posting a request for a complete PCB for the nRF905 433M loop antenna
RT. I downloaded the antenna, chip, and via files separately from the Nordic website. Is there anyone who can put them together? Thank you very much!...
rocklinsuv RF/Wirelessly
About ADC module
What is the use of the reference voltage for ADC conversion? What effect does different reference voltages have on the conversion results?...
chuzhitian Microcontroller MCU
Friends who are familiar with the 4-op-amp LF444, please help me take a look
See the attached circuit diagram. The three terminals of the op amp input are divided by precision resistors as offset. By comparing with the voltage of the 4th terminal input (about 0.9--2V), the 4th...
chenkangrong Power technology
Briefly talk about the three major BAS manufacturers and brands
Non-professionals are not allowed to comment, so let me share some ideas with you: Let me talk about Siemens first. I think Siemens' S600 peak system is very good. They have launched many new products...
小瑞 Industrial Control Electronics
How to debug a 50Hz notch filter
I want to ask you experts, how to effectively debug the notch filter? No matter how I change the resistors and capacitors, I can't debug the center frequency and bandwidth to the right level....
tangjc2001 Analog electronics

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1476  2317  2188  518  1576  30  47  45  11  32 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号