802-048Z121-22PSA-03N

Description
Circular Connector Adapter
CategoryThe connector    The connector   
File Size176KB,1 Pages
ManufacturerGlenair
Websitehttp://www.glenair.com/
Download Datasheet Parametric View All

802-048Z121-22PSA-03N Overview

Circular Connector Adapter

802-048Z121-22PSA-03N Parametric

Parameter NameAttribute value
Objectid7049774696
Reach Compliance Codecompliant
ECCN codeEAR99
Other featuresAQUAMOUSE
Body/casing typeRECEPTACLE-RECEPTACLE
Connector typeCIRCULAR CONNECTOR ADAPTER
Contact point genderMALE-FEMALE
DIN complianceNO
empty shellNO
Filter functionNO
IEC complianceNO
MIL complianceNO
Mixed contactsNO
OptionsHERMETIC
Shell materialSTAINLESS STEEL
Total number of contacts22
802-048 Ordering Information
Series 802 Hermetic Jam Nut Mount Bulkhead Feed–Thru Receptacles
feature
gold plated iron alloy contacts and compression glass dielectric material. The
316 series stainless steel connector shell provides excellent corrosion protection.
Available in PS, SP, PP and SS for PP or SS application, power applied to a given
contact on one end will result in power to contact directly opposite, regardless of
contact identification letter. DWV of contact size #23 is 500 VAC with sizes #20, #16
and #12 rated at 1800 VAC. Hermeticity is rated at: 1 x 10
-7
ccHe/sec @ 1 atmosphere
differential. 802-048 is designed to mate with Glenair 802 Series plugs
How To Order
Sample Part Number
Series
Shell Material and Finish
Shell Size - Insert
Arrangement
Contact Type
Jam Nut Side
Contact Type
Opposite Side
Keyway Position
(See Table I)
Panel Thickness
(See Table II)
O-ring Material
802-048
802-048
= Bulkhead Feed–Thru Hermetic Receptacle
Z1
= Stainless Steel / Passivated RoHS Compliant
ZL
= Stainless Steel / Nickel Plated
INC
= Inconel 600
See Table III
P
= Pin
S
= Socket
P
= Pin
S
= Socket
A
= Normal
B
= Pos. B
C
= Pos. C
D
= Pos. D
-01
= .125/.500
-04
= 1.500/2.00
-07
= 3.000/3.500
See Table IV
-02
= .500/1.00
-05
= 2.000/2.500
-08
= 3.500/4.000
E
= Pos. E
Z1
12-37
P
S
A
01
D
F
= Pos. F
-03
= 1.00/1.500
-06
= 2.500/3.000
Table I: Key Positions
Table II: Panel Thickness
Panel
Thickness
Code
-01
-02
-03
-04
-05
H Panel
Thickness
.125/.500
.500/1.000
1.000/1.5000
1.500/2.000
2.000/2.500
2.500/3.000
3.000/3.500
3.500/4.000
J Maximum
Length
1.750
2.250
2.750
3.250
3.750
4.250
4.750
5.250
Table III: Insert Arrangements
Shell Size
5
6
7
8
9
10
12
14
15
21
Insert Arrangement(s)
-3
-1, -4, -6, -7, -23
-1, -10, -25
-1, -2, -13, -28, -200
-4, -19, -200, -201, -210
-2, -5, -26, -200, -201, -202
-2, -3, -7, -37, -200, -201, -220
-2, -5, -12, -55, -235
-3, -7, -14, -85, -241
-5, -12, -22, -130, -269
A° B°
Key Position
A
Normal
B
C
D
E
F
Key Rotation
150°
75°
95°
140°
75°
95°
210°
210°
230°
275°
275°
210°
-06
-07
-08
Table IV: O-ring Material
Designator
C
E
V
N
Material
Fluorosilicone, Conductive
EPDM
Viton
Nitrile
Designator
S
B
K
Material
Silicone
Butyle Rubber
Kalrez
Dimensions in Inches (millimeters) are subject to change without notice.
© 2014 Glenair, Inc.
Series 80 Mighty Mouse
U.S. CAGE Code 06324
Printed in U.S.A.
GLENAIR, INC.
1211 AIR WAY
GLENDALE, CA 91201-2497
818-247-6000
FAX 818-500-9912
www.glenair.com
E-21
E-Mail: sales@glenair.com
Series 802
Series 802 AquaMouse™ Hermetic
Jam Nut Mount Bulkhead Feed–Thru
E
NUCLEO_G431RB Review Add UART
[i=s]This post was last edited by viphotman on 2019-10-9 13:30[/i]Add UART to NUCLEO_G431RB ADC evaluation routine A hardware circuitThe UART of G431 is connected to the virtual serial port of ST LINK...
viphotman stm32/stm8
LPC1549 GPIO P0.27 output problem
[i=s]This post was last edited by littleshrimp on 2014-8-14 09:09[/i] When adjusting the SPI of LPC1549, I want to use GPIO to control the level of P0.27. The data of DIR and PIN registers in the code...
littleshrimp NXP MCU
Help with some symbols on the schematic [B,N,JP]
I got a PDF schematic. This is the HDMI connection, the other side is the network label, until the HDMI ESD device, what is the B label?Below is the HDMI ESD device, what is the N label?This is the I2...
cl17726 PCB Design
Are you a Stellaris fan? Come grab an iPad or iTouch! The promotion is almost over!
See which friend can win the prize! Looking forward to it!I hope he and other friends can make greater contributions to the forum and everyone!Congratulations first!...
蓝雨夜 Microcontroller MCU
Reminiscing about the days when we held TI seminars
First of all, when I was in Harbin, I attended a seminar. I must have registered online first, and then followed the map to find the star-rated hotel where the seminar was held, and then found the ven...
gaoyang9992006 TI Technology Forum
What is the effect of connecting the negative pole of the electrolytic capacitor to the ground after connecting the resistor?
:) I saw a circuit board where the +3.3V power supply was processed. A 10KΩ resistor was added behind the negative electrode of the (16V/10UF) electrolytic capacitor, and then connected to the analog ...
langzi291 Power technology

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1210  1728  796  1823  470  25  35  17  37  10 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号