EEWORLDEEWORLDEEWORLD

Part Number

Search

804-021-02M12-203PC

Description
Circular Connector, 16 Contact(s), Aluminum Alloy, Male, Solder Terminal, Plug,
CategoryThe connector    The connector   
File Size592KB,4 Pages
ManufacturerGlenair
Websitehttp://www.glenair.com/
Download Datasheet Parametric View All

804-021-02M12-203PC Overview

Circular Connector, 16 Contact(s), Aluminum Alloy, Male, Solder Terminal, Plug,

804-021-02M12-203PC Parametric

Parameter NameAttribute value
Objectid7191205265
Reach Compliance Codecompliant
ECCN codeEAR99
YTEOL8.67
Other featuresPOLARIZED
Back shell typeSOLID
Body/casing typePLUG
Connector typeCIRCULAR CONNECTOR
Contact point genderMALE
Coupling typeSNAP
DIN complianceNO
empty shellNO
Environmental characteristicsIMMERSION RESISTANT
Filter functionNO
IEC complianceNO
MIL complianceNO
Plug informationMULTIPLE MATING PARTS AVAILABLE
Mixed contactsNO
Installation typeBOARD AND PANEL
OptionsWATERPROOF
Shell surfaceNICKEL PLATED
Shell materialALUMINUM ALLOY
Housing size12
Termination typeSOLDER
Total number of contacts16
Series 804 Push-Pull Mighty Mouse
PC Tail or Solder Cup Panel Mount Plug
804-009, 804-021 Ordering Information
Panel Mount Plugs
save space inside the box compared to Series 804 removable
contact receptacles. Factory-installed non-removable contacts. Solder cup or
printed circuit board terminals. Available in front or rear panel and flange mount
versions.
Ingress Protection, Unmated
Specify
804-009
connectors for applications where
open face water immersion is not a requirement. For IP67 ingress protection and
MIL-STD-810 Method 512 immersion requirements, specify
804-021
watertight
connectors certified to meet one atmosphere pressure differential in open face
condition from -40° to +70°C.
"Push-Pull" Quick-Disconnect
Canted spring securely retains the mating plug.
How To Order
Sample Part Number
Series
G
-00
Jam Nut, Front Panel
Mount
Series 804
Shell Style (See Table I)
Shell Material and Finish
Shell Key Positions
(See Table II)
Table I: Shell Style
-07
Jam Nut, Rear Panel
Mount
© 2014 Glenair, Inc.
804-009
804-009
= Panel Mount Plug, Standard Potting
804-021
= Panel Mount Plug
,Resilient Silicone Potting for
Watertight Seal from -40° to +70°C (1 ATM Pressure Differential)
-00
= Front Panel Mount Jam Nut (See Table IV)
-02
= Flange Mount
-07
= Rear Panel Mount Jam Nut (See Table III)
C
= Aluminum / Black Anodize (Non-Conductive); RoHS Compliant
M
= Aluminum / Electroless Nickel; RoHS Compliant
MT
= Aluminum / Nickel-PTFE RoHS Compliant
NF
= Aluminum / Cadmium with Olive Drab Chromate
ZNU
= Aluminum / Zinc-Nickel with Black Chromate
Z1
= Stainless Steel / Passivated; RoHS Compliant
-07
NF
10-26
E
A
Shell Size - Insert Arrangement
See Contact Arrangements Page G-2
P
= Pin, PC Tail
E
= Pin, Solder Cup
Contact Type
S
= Socket, PC Tail
F
= Socket, Solder Cup
Omit
= Single Master Key
A
= Normal
B
= Pos. B
C
= Pos. C
D
= Pos. D
E
= Pos. E
F
= Pos. F
Table II: Alternate Keyway Positions
Pos.
150°
75°
95°
140°
75°
95°
210°
210°
230°
275°
275°
210°
A
B
-02
Flange Mount
C
D
E
F
Dimensions in Inches (millimeters) are subject to change without notice.
Series 80 Mighty Mouse
U.S. CAGE Code 06324
Printed in U.S.A.
GLENAIR, INC.
1211 AIR WAY
GLENDALE, CA 91201-2497
818-247-6000
FAX 818-500-9912
www.glenair.com
G-12
E-Mail: sales@glenair.com
Ramtron launches 8051 MCU with embedded FRAM
Ramtron International has released the VRS51L3074, the world's first 8051 MCU embedded with non-volatile FRAM memory. Ramtron has added FRAM to its high-speed and flexible Versa 8051 series to enable ...
rain 51mcu
msp430 interrupt query
if(CH376_SPI_INT==BIT7) { P2IFG=~BIT7; return TRUE;} else { P2IFG=~BIT7; return FALSE; } Query 2.7 interrupt. Without _EINT() to open global interrupt, can the interrupt be queried by querying the int...
kaka0202 Microcontroller MCU
avr 5110
Is there any program to drive Nokia5110 with avr mega128, preferably with ad da...
卢沟晓 LED Zone
TI Analog Engineer's Pocket Reference
A practical e-book that captures 50 years of analog design experience, a handy reference for analog engineers. [list] [*]Key constants and transformations[*]Basic op amp configuration[*]Sensor overvie...
dcexpert Analogue and Mixed Signal
Could you please give me some advice, can the following circuit be established? What is the reason why it cannot be established?
[img]http://images22.51.com/6000/tf_digital/87d285dd879de62385f561622f9df420.jpg[/img] The circuit is drawn by myself, and my personal analysis is as follows. I hope you can correct me if there are an...
xiong8707 Analog electronics
24C04 Read and write problems after FF
I am using 51 to read and write to 24C04. I encountered a problem, that is, the data after the read and write address 0xff exceeds the 8-bit address. How can I read the data after the 0xff address?Sin...
米兰的小工匠 51mcu

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 904  1114  603  1815  746  19  23  13  37  16 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号