EEWORLDEEWORLDEEWORLD

Part Number

Search

DP3-41

Description
sensor pressure 100kpa gauge
CategoryThe sensor   
File Size665KB,14 Pages
ManufacturerPanasonic
Websitehttp://www.panasonic.co.jp/semicon/e-index.html
Environmental Compliance  
Download Datasheet Parametric Compare View All

DP3-41 Overview

sensor pressure 100kpa gauge

DP3-41 Parametric

Parameter NameAttribute value
Datasheets
DP3 Series
Product Photos
DP3-41
Standard Package1
CategorySensors, Transducers
FamilyPressure Sensors, Transducers
Pressure TypeGauge
Operating Pressure14.50 PSI, 100 kP
Port SizeRc 1/8", 0.125" (3.175mm)
OutpuOpen Collec
Accuracy-
Voltage - Supply12 V ~ 24 V
Termination StyleCable
Operating Temperature-10°C ~ 50°C
Package / CaseModule Box with Display
Factory Setting-
Dynamic CatalogDP3 Series
Other Names1110-2391
PRESSURE SENSORS
DP3
SERIES
Digital
Auto reference
Digital Pressure Sensor with Auto-reference Function
DP5/DPH
Head-separated
DP2
DP3
Digital Display
DP4
High accuracy sensing
at all times with auto-
reference function
* Passed the UL 991 Environment Test
* UL 61010C-1 compatible, Passed the UL 991 Environment Test based on SEMI S2-0200.
[Category applicable for semiconductor manufacturing: TWW2, Process Equipment]
[Applicable standards: UL 61010C-1]
[Additional test / evaluation standards as per intended use: UL991, SEMI S2-0200]
Conforming to
EMC Directive
UL Recognition
Incorporates auto-reference function
Unaffected by changes in reference pressure
By an external signal, the set (threshold) values are
corrected by being shifted by an amount equal to the
pressure change. Hence, judgment by the sensor is
as accurate as before the reference pressure change.
This function is extremely suitable in places having
intense variations in the reference pressure or where
fine settings are required.
DP-M
Example of air-leak test
Threshold level
Auto-reference function follows
reference pressure changes
PE
LED Bar Display
OK
Reference pressure
NG
res
ep
enc
fer
Re hange
c
sur
e
NG?
NG
OK
NG
Reference
pressure
Reference
pressure
Pressure sensor not incorporating
auto-reference function
Reference
pressure
DP3
series
Before reference pressure change
After reference pressure change
Total cost reduction
Till now...one sensor was required for each suction
nozzle
Since the threshold level differs with the suction nozzle, a
sensor was required for each suction nozzle, increasing
the cost significantly.
In case of DP3...operation efficiency UP!
Since the threshold level can be automatically changed
by the auto-reference function, two suction nozzles can
be used, alternately, with one sensor.
DP3-80
MODE
(
Atmospheric
pressure
)
Suction nozzle for trimmers
Auto-refer-
ence input
Suction nozzle for
chip components
Threshold
level for
suction nozzle
for trimmers
Threshold
level for
suction nozzle
for chip
components
For chip components
Vacuum
Before suction Suction OK Suction NG Suction over
Electromagnetic valve
For trimmers
808
Ramco Innovations - 1207 Maple Street, West Des Moines IA USA 50265 - 800-280-6933 - www.ramcoinnovations.com

DP3-41 Related Products

DP3-41 DP3-42 DP3-80 DP3-21 DP3-20 DP3-22 MS-DPX MS-DPX-4 MS-DPX-2
Description sensor pressure 100kpa gauge sensor pressure 1mpa gauge sensor pressure -101.3kpa gauge sensor pressure 100kpa gauge sensor pressure -101.3kpa gauge sensor pressure 1mpa gauge L-shaped bracket surface mount back mounting bracket panel mounting bracket
Standard Package 1 1 1 1 1 1 - - -
Category Sensors, Transducers Sensors, Transducers Sensors, Transducers Sensors, Transducers Sensors, Transducers Sensors, Transducers - - -
Family Pressure Sensors, Transducers Pressure Sensors, Transducers Pressure Sensors, Transducers Pressure Sensors, Transducers Pressure Sensors, Transducers Pressure Sensors, Transducers - - -
Pressure Type Gauge Gauge Gauge Gauge Gauge Gauge - - -
Operating Pressure 14.50 PSI, 100 kP 145 PSI -14.65 ~ +0 PSI, -101 ~ 0 kP 14.50 PSI, 100 kP -14.65 ~ +0 PSI, -101 ~ 0 kP 145 PSI - - -
Port Size Rc 1/8", 0.125" (3.175mm) Rc 1/8", 0.125" (3.175mm) Female, M5 Rc 1/8", 0.125" (3.175mm) Rc 1/8", 0.125" (3.175mm) Rc 1/8", 0.125" (3.175mm) - - -
Outpu Open Collec Open Collec Open Collec Open Collec Open Collec Open Collec - - -
Voltage - Supply 12 V ~ 24 V 12 V ~ 24 V 12 V ~ 24 V 12 V ~ 24 V 12 V ~ 24 V 12 V ~ 24 V - - -
Termination Style Cable Cable Cable Cable Cable Cable - - -
Operating Temperature -10°C ~ 50°C -10°C ~ 50°C -10°C ~ 50°C -10°C ~ 50°C -10°C ~ 50°C -10°C ~ 50°C - - -
Package / Case Module Box with Display Module Box with Display Module Box with Display Module Box with Display Module Box with Display Module Box with Display - - -
Dynamic Catalog DP3 Series DP3 Series DP3 Series DP3 Series DP3 Series DP3 Series - - -
Other Names 1110-2391 1110-2406 1110-2408 1110-2392 1110-2409 1110-2404 - - -
[NXP Rapid IoT Review] SWD Programming Procedure Notes
Rapid-IoT can use SWD for debugging. If you don't buy the hexiwear baseboard and don't plan to make your own expansion board, you can pry open the shell and fly out the SWD signal to connect to the ex...
cruelfox RF/Wirelessly
Basic Knowledge Lecture Hall - Twenty Questions and Answers on Basic Power Supply Knowledge
There are 20 questions below, and each question has an answer. But please don't rush to check the answers after seeing the questions. Try to answer them yourself to see how much knowledge you have abo...
songbo Power technology
Recruiting interns and part-time engineers who develop on WinCE
1. The development location is in Shanghai. We hope you are a local student in Shanghai (graduate students are preferred). 2. We hope you don't care about the size of the company, but only care about ...
pmns Embedded System
Does anyone have a Renesas CS+ license?
[color=#333333][backcolor=rgb(255, 255, 255)][font=微软雅黑][size=18px]Does anyone have a license for CS+ for CC? I am planning to develop something with Renesas in the near future. CS+ prompts “W0511179:...
aozhouduwangyu Renesas Electronics MCUs
[Zhu Zhaoqi takes you to learn embedded systems] Chapter 2 Section 6 U-Boot-2013.04 Startup Analysis 2
Next is to execute the jump instruction "bl lowlevel_init" with return. Call the lowlevel_init function (located in board\samsung\smdk6410\lowlevel_init.s). The job of the lowlevel_init function is to...
qinkaiabc ARM Technology
MPC8xx BDM Download Cable/Debugger for Sale
The MPC8xx BDM download cable/debugger is specially used for downloading and debugging bootrom and vxworks images in the process of developing embedded systems based on PowerPC processors under Window...
86814429 Embedded System

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 125  722  1282  2730  1879  3  15  26  55  38 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号