EEWORLDEEWORLDEEWORLD

Part Number

Search

HL5100-G

Description
Basic/snap-action/limit switch LS pin plug ground Terminal
CategoryTopical application    Mechanical and electrical/engineering/automation   
File Size716KB,6 Pages
ManufacturerAll Sensors
Environmental Compliance
Download Datasheet Parametric Compare View All

HL5100-G Overview

Basic/snap-action/limit switch LS pin plug ground Terminal

HL5100-G Parametric

Parameter NameAttribute value
MakerAll Sensors
Product CategoryBasic/Snap Action/Limit Switch
RoHSyes
General-purpose Limit Switch
HL-5000
Economical, Miniature Limit Switch Boasting
Rigid Construction
The Head, Box, and Cover mate with ridged surfaces to maintain
strength.
A unique Head structure provides a large OT for smooth operation.
Easy-to-wire conduit opening design.
Ideal for application in printing machines, forming machines, and light
machines.
(High Switches with high sealing characteristics, such as WL or D4C
Switches, in locations subject to oil, water, or precipitation.)
Models with grounding terminals conform to the CE marking.
Approved by CCC (Chinese standard).
(Ask your OMRON representative for information on approved models.)
Be sure to read
Safety Precautions
on page 4 to 5 and
Safety Precautions for All Limit Switches.
CSM_HL-5000_DS_E_3_1
Model Number Structure
Model Number Legend
(Not all combinations are possible. Ask
your OMRON representative for details.)
Specifications
Approved Standards
Agency
CCC (CQC)
Standard
GB14048.5
File No.
2003010303077624
HL-5
@@
å`HL-5ņņ
(1)(2)
(1) Actuators
000: Roller lever
030: Adjustable roller lever
050: Adjustable rod lever
100: Sealed plunger
200: Sealed roller plunger
300: Coil spring
Note: Ask your OMRON representative for information on approved models.
Ratings
Rated
voltage
125 VAC
250 VAC
12 VDC
24 VDC
125 VDC
250 VDC
Non-inductive load (A)
Resistive
Lamp load
load
NC
NO
NC
NO
5
1.5
0.7
5
1
0.5
5
3
5
3
0.4
0.2
0.4
0.2
Inductive load (A)
Inductive
Motor load
load
NC
NO
NC
NO
3
2
1
3
1.5
0.8
4
3
4
3
(2) Ground Terminal Specifications
Blank : Without ground terminal
G
: With ground terminal/M5 tapping on the rear side
Ordering Information
Actuator
Roller lever
Adjustable
roller lever
Adjustable
rod lever
Sealed
plunger
Sealed roller
plunger
Coil spring
Model
HL-5000
*
Note: 1. The above figures are for steady-state currents.
2. Inductive loads have a power factor of 0.4 min. (AC) and a time
constant of 7 ms max. (DC).
3. Lamp load has an inrush current of 10 times the steady-state current.
4. Motor load has an inrush current of 6 times the steady-state current.
HL-5030
*
Inrush NC
current NO
24 A max.
12 A max.
HL-5050
*
Approved Standard Ratings
CCC (GB14048.5)
Applicable category and ratings
AC-15 3 A/250 VAC
HL-5100
*
HL-5200
HL-5300
* HL-5000 Limit Switches are offered with a choice of ground terminal/M5
tapping on the rear side conforming to various standards. When placing an
order, add the code to the model number to indicate if ground terminal/M5
tapping on the rear side is required.
-G: with ground terminal/M5 tapping on the rear side.
1

HL5100-G Related Products

HL5100-G HL-5201 HL-5100 HL-5200 HL-5500
Description Basic/snap-action/limit switch LS pin plug ground Terminal Basic/quick action/limit switch limit switch Basic/snap action/limit switch LS pin plunger Basic/snap action/limit switch LS roller plunger Basic/snap action/limit switch LS remote plunger
Maker All Sensors All Sensors All Sensors All Sensors All Sensors
Product Category Basic/Snap Action/Limit Switch Basic/Snap Action/Limit Switch Basic/Snap Action/Limit Switch Basic/Snap Action/Limit Switch Basic/Snap Action/Limit Switch
RoHS yes no yes yes yes
ADS Antenna Matching Simulation Design
1Open ADS and create a new project fileClick Create A New Project and the following dialog box will pop up:Two points to note here: 1. Project Technology Files must select the correct unit, usually mi...
btty038 RF/Wirelessly
Japan has set five major medical electronic technology directions by 2020
[i=s] This post was last edited by 5525 on 2016-5-25 21:04 [/i] 1. Robots that can perform or assist in surgery 2. Artificial organs 3. Low-invasive medical devices 4. Image diagnostic equipment 5. Me...
5525 Robotics Development
Looking for a job as a hardware development engineer.
My surname is Li, I am a second-rate student from a second-rate school [a junior college student who also makes trouble], looking for a full-time hardware R&D engineer, or in the electronic technology...
cl17726 Recruitment
Why do we need VLANs?
[p=25, null, left][b]Why do we need VLAN[/b][/p][p=25, null, left]1. What is VLAN?[/p][p=25, null, left]VLAN (Virtual LAN) is translated into Chinese as "Virtual Local Area Network". A LAN can be a ne...
qwqwqw2088 Mobile and portable
Programming of PWM square wave generation for CC430f5137 series microcontrollers,
This is the program I wrote to generate PWM waves. It doesn't work properly. Please help me. Thank you. void pwm(void) {P1DIR |= 0x02; // P1.1 output(ccR0)TA1CCTL0 = CCIE; // CCR0 interrupt enabledTA1...
yyhlsl Microcontroller MCU
Help with 1602 LCD display problem, how to display a variable
sprintf(Data,"%d",temp); LCD_Write_String(0,0,Data); DelayMs(200); But it can't be displayed on the machine. Data is an array, temp is a char type variable. What I want to do is to display the value o...
ll6030711 51mcu

Technical ResourceMore

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 552  886  505  509  2668  12  18  11  54  44 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号