EEWORLDEEWORLDEEWORLD

Part Number

Search

D4C-2720

Description
Basic/quick action/limit switch limit switch
CategoryTopical application    Mechanical and electrical/engineering/automation   
File Size754KB,23 Pages
ManufacturerAll Sensors
Environmental Compliance
Download Datasheet Parametric View All

D4C-2720 Online Shopping

Suppliers Part Number Price MOQ In stock  
D4C-2720 - - View Buy Now

D4C-2720 Overview

Basic/quick action/limit switch limit switch

D4C-2720 Parametric

Parameter NameAttribute value
MakerAll Sensors
Product CategoryBasic/Snap Action/Limit Switch
RoHSyes
typeLimi
Enclosed Switch
D4C
Compact Limit Switch That's Also
Thin and Highly Sealed
Approved by EN, UL, CSA, and CCC (Chinese standard).
(Ask your OMRON representative for information on approved models.)
Sealing characteristics that meet IEC IP67 degree of protection.
Triple-sealed construction:
Plunger section sealed via nitrile rubber packing seal and
diaphragm; switch section sealed via nitrile rubber cap;
cable entrance sealed via encapsulating material.
Cable lengths of 3 and 5 m available on standard models.
Models also available with UL and CSA-certified cables.
Multiple mounting possible with Switches with Plungers.
Models with red LED indicators added to series for easy
confirmation of operation.
(Set by default to light for non-operation.)
VCTF cables with CE marking.
(Applicable only to standard models.)
Be sure to read
Safety Precautions
on page 13 to 14 and
Safety Precautions for All Limit Switches.
Model Number Structure
Model Number Legend
Standard Models
Pre-wired Models
Weather-resistant Models
D4C-@@@
(1) (2)(3)
(1) Rated Current
1: 5 A at 250 VAC, 4 A at 30 VDC
2: 5 A at 125 VAC (with LED indicator)
3: 4 A 30 VDC (with LED indicator)
4: 0.1 A at 125 VAC, 0.1 A at 30 VDC
5: 0.1 A at 125 VAC (with LED indicator)
6: 0.1 A at 30 VDC (with LED indicator)
D4C-@0@@-@@@@@@
(1)
(2)
(3)
(4)
(1) Rated Current
1: 1 A at 125 VAC, 1 A at 30 VDC
(Without operation indicator)
2: 1 A at 125 VAC (with operation indicator)
3: 1 A at 30 VDC (with operation indicator)
D4C-@@@-P
(1)(2)(3) (4)
(1) Rated Current
1: 5 A at 250 VAC, 4 A at 30 VDC
2: 5 A at 125 VAC (with LED indicator)
3: 4 A at 30 VDC (with LED indicator)
4: 0.1 A at 125 VAC, 0.1 A at 30 VDC
(2) Actuator
01: Pin plunger
02: Roller plunger
31: Sealed plunger
32: Sealed roller plunger
24: Roller lever (high-sensitivity model)
(2) Cable Specifications
2: VCTF oil-resistant cable (3 m)
3: VCTF oil-resistant cable (5 m)
(2) Cable Specifications
2: VCTF oil-resistant cable (3 m)
3: VCTF oil-resistant cable (5 m)
4: VCTF (3 m)
5: VCTF (5 m)
6: SJT(O) (3 m)
7: SJT(O) (5 m)
(3) Actuator
20: Roller lever
24: Roller lever (high-sensitivity model)
27: Adjustable roller lever
29: Adjustable rod lever
(3) Wiring Specifications
DK1EJ: Pre-wired models
(3 conductors: DC specification)
AK1EJ: Pre-wired models
(3 conductors: AC specification)
M1J: Connector models for ASI devices
(2 conductors: NO wiring)
(3) Actuator
01: Pin plunger
02: Roller plunger
03: Crossroller plunger
20: Roller lever
24: Roller lever (high-sensitivity model)
31: Sealed pin plunger
32: Sealed roller plunger
33: Sealed crossroller
50: Plastic rod
60: Center roller lever
(4) Structure
P: Weather-resistant
(4) Cable length
03: 0.3 m
Wiring Specifications
Internal switch
COM
NC
NO
Connector
3
2
4
http://www.ia.omron.com/
(c)Copyright OMRON Corporation 2007 All Rights Reserved.
1
Wuxi Huada Guoqi Technology Co., Ltd. is recruiting a custom layout engineer
Dear students, my name is Guan Zhiyong. The IP development department of Wuxi Huada Guoqi Technology Co., Ltd. is recruiting a custom layout engineer. The work location is in Shanghai, specifically on...
guanzhiyong Recruitment
[Repost] Dedicated to embedded beginners who are persistent in knowledge, welcome experts to add to the discussion
Practice is of course the best way to train people, but I think that students in school rarely have such opportunities, let alone undergraduates, and even postgraduates may not have the conditions. So...
zhu Embedded System
Looking for iar for stm8 and corresponding registration machine software
I have just joined the ranks of those who are learning stm8, but I can't find any software I can use on the Internet. Please help me. . . . {:1_85:}...
wzb2015 stm32/stm8
Analysis of Simple Self-Excited Oscillator Circuit
[size=4]The light bulb in the figure represents the speaker.[/size] [size=4]When the switch is pressed, the current charges the capacitor from the path of X1-->C1--->R1--->Q1 base--->Q1--->emitter----...
fish001 Analogue and Mixed Signal
How to automatically display console data in different locations on the terminal
How to automatically divide the console data into workstations and display them on the terminal Example: The workstation numbers are divided into A, B, C, D, E, and F and displayed on terminals A, B, ...
zhutn Embedded System
Can L298 drive a 57 stepper motor rated at 1.5A?
The maximum voltage of chip L298 is 50V, the current is 2A, and the peak value is 4A. As shown in the figure, the A\B\C\D terminals are used as the input signal terminals of the 51 single-chip microco...
GLINT MCU

Technical ResourceMore

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2471  44  2177  1601  124  50  1  44  33  3 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号