EEWORLDEEWORLDEEWORLD

Part Number

Search

D4E-1A10N

Description
Basic/quick action/limit switch roller plunger 5A
CategoryTopical application    Mechanical and electrical/engineering/automation   
File Size617KB,15 Pages
ManufacturerAll Sensors
Environmental Compliance
Download Datasheet Parametric Compare View All

D4E-1A10N Online Shopping

Suppliers Part Number Price MOQ In stock  
D4E-1A10N - - View Buy Now

D4E-1A10N Overview

Basic/quick action/limit switch roller plunger 5A

D4E-1A10N Parametric

Parameter NameAttribute value
MakerAll Sensors
Product CategoryBasic/Snap Action/Limit Switch
RoHSyes
Contact rating5 Amps at 125 Volts, 250 Volts
ActuatorRoller Plunge
work force1200 gf
Termination typeScrew
typeMiniature Enclosed Limit Switch
Small Sealed Switch
D4E-@N
Slim and Compact Switch with Better Seal
and Ensuring Longer Service Life than D4E
• Flat springs with an improved lever ratio of the built-in switch en-
sure smooth snap action and long life expectancy.
• Protection cover protects the built-in switch from dust and oil.
Plunger incorporates a tough seal cap that lasts for a long time.
• One touch connector eliminates need for tedious wiring opera-
tions and reduces downtime for wiring and maintenance (mod-
els with standard, easy-to-use screw terminals are also
available).
• Minute load model with gold cladding is optimal for electronic
control.
• Molded terminal types as well as molded terminal types with op-
erating indicator lamps are available for screw terminal systems.
• No difference in mounting pitch and characteristics between
D4E-@N and D4E models.
• Approved by EN, UL, CSA, and CCC (Chinese standard).
Model Number Structure
Model Number Legend
D4E-@@@@@N
1 2
3
4
3. Terminals
00: AC connector
10: DC connector
20: Screw terminals without a cable
21: Screw terminals with a cable (right-hand)
22: Screw terminals with a cable (left-hand)
23: Molded terminals with a cable (right-hand)
24: Molded terminals with a cable (left-hand)
(Cable is S-FLEX VCTF 3 m)
4. Operation Indicator
None: Without operation indicator
L:
Neon lamp (250 VAC)
L2: LED (24 VDC)
Note: 1.
Only the molded terminal models can be equipped with an
operation indicator.
2.
Desired Switches may not be manufactured depending on
the combination between molds and indicators. Contact our
sales representative for further information.
1. Rated Current
1:
5 A at 125 VAC
(1 A at 125 VAC/30 VDC for model with a connector)
2:
0.1 A at 125 VAC
(0.1 A at 125 VAC/30 VDC for model with a connector)
2. Actuator
A:
Roller plunger
B:
Crossroller plunger
C:
Plunger
D:
Sealed roller plunger
E:
Sealed crossroller plunger
F:
Sealed plunger
G:
Roller lever
H:
One-way action roller lever
138
Small Sealed Switch
D4E-@N

D4E-1A10N Related Products

D4E-1A10N D4E-1C20N D4E-1C10N
Description Basic/quick action/limit switch roller plunger 5A Basic/snap action/limit switch lsw plunger W/ocable Basic/snap action/limit switch plain top plunger 5A
Maker All Sensors All Sensors All Sensors
Product Category Basic/Snap Action/Limit Switch Basic/Snap Action/Limit Switch Basic/Snap Action/Limit Switch
RoHS yes yes yes
Contact rating 5 Amps at 125 Volts, 250 Volts 5 Amps 5 Amps at 125 Volts, 250 Volts
Actuator Roller Plunge Plunge Plunge
work force 1200 gf 42.24 oz 1200 gf
Termination type Screw Screw Screw
type Miniature Enclosed Limit Switch Enclosed Limit Switch Miniature Enclosed Limit Switch
GPIO push-pull mode and open-drain mode in ARM
Please give a brief introduction to the push-pull and open-drain modes of GPIO in ARM...
hu820 ARM Technology
Why can’t I insert column COLUMN in LIST CTRL? Urgent question
Why can't I insert column COLUMN in LIST CTRL? Code: BOOL InitListView(HWND hwndLV) { LV_COLUMN lvc; int i; TCHAR *szColumn[] = {_T("HosN"), _T("PatN"), _T("PatID ")}; int widths[] = {120,100,130}; hw...
hyw123456 Embedded System
Experts, how can I use EVC to write a joystick test program under WINCE?
I use a HJ6-RS232 joystick to communicate with an embedded single-board computer through a serial port for industrial control. It is an SBC9315 single-board computer with an ARM920T core and runs Wind...
ta7680cd7698 Embedded System
ATMEGA128/ATMEGA169 onboard ISP download port compatible design
People who have used M16/32 and M64/128 may be confused. The ISP download interface connection pins of these two AVR microcontrollers are different. This caused us a lot of trouble when designing. The...
tiankai001 Microchip MCU
Angle displacement sensor recommendation
Please recommend a foreign brand of angle displacement sensor. . . . ....
cs184778165 Industrial Control Electronics
Data recorded by vehicle driving recorder should have legal effect
In recent years, road traffic accidents in my country have occurred frequently and are on the rise, causing huge losses to people's lives and property. According to analysis, most accidents are caused...
frozenviolet Automotive Electronics

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 166  1886  1531  2714  1260  4  38  31  55  26 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号