Parameter NameAttribute value
MakerAll Sensors
Product CategoryBasic/Snap Action/Limit Switch
RoHSyes
typeLimi
Enclosed Switch
D4C
Compact Limit Switch That's Also
Thin and Highly Sealed
Approved by EN, UL, CSA, and CCC (Chinese standard).
(Ask your OMRON representative for information on approved models.)
Sealing characteristics that meet IEC IP67 degree of protection.
Triple-sealed construction:
Plunger section sealed via nitrile rubber packing seal and
diaphragm; switch section sealed via nitrile rubber cap;
cable entrance sealed via encapsulating material.
Cable lengths of 3 and 5 m available on standard models.
Models also available with UL and CSA-certified cables.
Multiple mounting possible with Switches with Plungers.
Models with red LED indicators added to series for easy
confirmation of operation.
(Set by default to light for non-operation.)
VCTF cables with CE marking.
(Applicable only to standard models.)
Be sure to read
Safety Precautions
on page 13 to 14 and
Safety Precautions for All Limit Switches.
Model Number Structure
Model Number Legend
Standard Models
Pre-wired Models
Weather-resistant Models
D4C-@@@
(1) (2)(3)
(1) Rated Current
1: 5 A at 250 VAC, 4 A at 30 VDC
2: 5 A at 125 VAC (with LED indicator)
3: 4 A 30 VDC (with LED indicator)
4: 0.1 A at 125 VAC, 0.1 A at 30 VDC
5: 0.1 A at 125 VAC (with LED indicator)
6: 0.1 A at 30 VDC (with LED indicator)
D4C-@0@@-@@@@@@
(1)
(2)
(3)
(4)
(1) Rated Current
1: 1 A at 125 VAC, 1 A at 30 VDC
(Without operation indicator)
2: 1 A at 125 VAC (with operation indicator)
3: 1 A at 30 VDC (with operation indicator)
D4C-@@@-P
(1)(2)(3) (4)
(1) Rated Current
1: 5 A at 250 VAC, 4 A at 30 VDC
2: 5 A at 125 VAC (with LED indicator)
3: 4 A at 30 VDC (with LED indicator)
4: 0.1 A at 125 VAC, 0.1 A at 30 VDC
(2) Actuator
01: Pin plunger
02: Roller plunger
31: Sealed plunger
32: Sealed roller plunger
24: Roller lever (high-sensitivity model)
(2) Cable Specifications
2: VCTF oil-resistant cable (3 m)
3: VCTF oil-resistant cable (5 m)
(2) Cable Specifications
2: VCTF oil-resistant cable (3 m)
3: VCTF oil-resistant cable (5 m)
4: VCTF (3 m)
5: VCTF (5 m)
6: SJT(O) (3 m)
7: SJT(O) (5 m)
(3) Actuator
20: Roller lever
24: Roller lever (high-sensitivity model)
27: Adjustable roller lever
29: Adjustable rod lever
(3) Wiring Specifications
DK1EJ: Pre-wired models
(3 conductors: DC specification)
AK1EJ: Pre-wired models
(3 conductors: AC specification)
M1J: Connector models for ASI devices
(2 conductors: NO wiring)
(3) Actuator
01: Pin plunger
02: Roller plunger
03: Crossroller plunger
20: Roller lever
24: Roller lever (high-sensitivity model)
31: Sealed pin plunger
32: Sealed roller plunger
33: Sealed crossroller
50: Plastic rod
60: Center roller lever
(4) Structure
P: Weather-resistant
(4) Cable length
03: 0.3 m
Wiring Specifications
Internal switch
COM
NC
NO
Connector
3
2
4
http://www.ia.omron.com/
(c)Copyright OMRON Corporation 2007 All Rights Reserved.
1
Design of Embedded Web Server Based on TMS320DM642
[size=5]Design of Embedded Web Server Based on TMS320DM642[/size] [size=5][/size] [size=5] [/size] [size=5][/size]...
Jacktang DSP and ARM Processors
Dear experts, I would like to ask how to add excitation to the HMC1043 geomagnetic sensor. Thank you.
Dear experts, I would like to ask how to add excitation to the HMC1043 geomagnetic sensor. Thank you....
JERRR Analog electronics
The DSL chips of the two boards handshake successfully through the ATM interface, but the ping fails.
What could be the reason for this? If you need any more information, please feel free to ask!...
chenls Embedded System
ucos ii interrupt task problem
I'm doing some ucos porting recently, but I use multiple interrupts to receive and send. In the system's interrupt management, I can nest interrupts, but in the task, I interrupt to receive data and t...
zouweihua Real-time operating system RTOS
Everyone please help me!!!
I want this circuit to have high current and high frequency. Is there any way? The limit is +-10...
sjhhhy Analog electronics
Rotating LED Problem
[i=s]This post was last edited by chenmoni on 2017-4-23 08:16[/i] I made a rotating LED according to the pictures and programs on the Internet, but the light is always on. Please help me find out if t...
chenmoni 51mcu

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2816  1683  1091  2154  360  57  34  22  44  8 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号