• Best-selling guard lock safety-door switch available in several
compact, multi-contact models
• Selectable Operation Key insertion direction and adjustable
mounting ensure installation flexibility
• Built-in switches with multiple-contact construction are available
• Key holding force of 1,300 N minimum
• Can be used for either standard loads or microloads
• Lineup includes models with a conduit size of M20
• IP67 degree of protection
• Variety of metallic heads available
g
Specifications
Standards and ec Directives
conforms to the following ec Directives:
• Machinery Directive
• Low Voltage Directive
• EN 1088
• EN 60204-1
• GS-ET-19
certified Standards
certification
body
TÜV SÜD
UL *1
CQC (CCC)
KOSHA *2
Standard
EN 60947-5-1
(certified direct opening)
UL 508, CSA C22.2 No.14
GB14048.5
EN60947-5-1
file no.
Consult your
representative for
details.
E76675
2003010305064267
2005-196
S
Ul/cSA (Ul 508, cSA c22.2 no. 14)
A300
rated
voltage
120 VAC
240 VAC
Q300
rated
voltage
125 VDC
250 VDC
carry
current
2.5 A
current (A)
make
0.55
0.27
Break
0.55
0.27
Volt-amperes (VA)
make
69
Break
69
carry
current
10 A
current (A)
make
60
30
Break
6
3
Volt-amperes (VA)
make
7,200
Break
720
Solenoid coil characteristics
item
type
24 VDc
24 VDC
-15%
Approx.
200 mA
+10%
110 VAc
110 VAC
±10%
Approx.
50 mA
Class F (130°C max.)
230 VAc
230 VAC
±10%
Approx.
30 mA
*1. Certification for CSA C22.2 No. 14 is certified by the UL mark.
*2. Only certain models have been certified.
Rated operating
voltage (100% ED)
Current consumption
Insulation Class
certified Standard ratings
tÜV (en 60947-5-1), ccc (gB14048.5)
item
Utilization category
Ac-15
3A
240 V
Dc-13
0.27 A
250 V
Rated operating current (Ie)
Rated operating voltage (Ue)
indicator characteristics
item
Rated voltage
Current consumption
Color (LED)
type
leD
10 to 115 VAC/VDC
Approx. 1 mA
Orange
Note: Use a 10 A fuse type gI or gG that conforms to IEC 60269 as a short-
circuit protection device. This fuse is not built into the Switch.
g64
OmrOn Scientific technOlOgieS, inc.
USA
Tel. 1/888/510-4357
canada
Tel. 1/866/986-6766
For the Latest Information
On the Internet:
www.sti.com
or
www.omron.ca
D4nl
Safety interlock Switches
connections
contact form
Indicates conditions where the Key is inserted and the lock is applied. Terminals 12 and 41 are connected internally (as per GS-ET-19).
contact
(door open/closed
detection and lock
monitor)
contact form
Door open/
lock
closed
monitor
detection
Door open/
closed detection
Lock monitor
model
Operating pattern
Lock position
remarks
D4NL-□AF□-□
1NC/1NO + 1NC/1NO
Zb
11
33
12
34
41
53
Zb
42
54
11-42
33-34
53-54
Stroke
Operation
Key insertion
completion position
Extraction
completion
position
ON
Only NC contacts 11-12
have a certified direct
opening mechanism.
The terminals 11-42,
33-34, and 53-54 can be
used as unlike poles.
Only NC contacts 11-12
have a certified direct
opening mechanism.
The terminals 11-42,
33-34, and 51-52 can be
used as unlike poles.
Only NC contacts 11-12
and 31-32 have a
certified direct opening
mechanism.
The terminals 11-42,
31-32, and 53-54 can be
used as unlike poles.
Only NC contacts 11-12
and 31-32 have a
certified direct opening
mechanism.
The terminals 11-42,
31-32, and 51-52 can be
used as unlike poles.
Only NC contacts 11-12
and 21-22 have a
certified direct opening
mechanism.
The terminals 11-42,
21-22, 33-34, and 53-54
can be used as unlike
poles.
Only NC contacts 11-12
and 21-22 have a
certified direct opening
mechanism.
The terminals 11-42,
21-22, 33-34, and 51-52
can be used as unlike
poles.
Only NC contacts 11-12,
21-22, and 31-32 have a
certified direct opening
mechanism.
The terminals 11-42,
21-22, 31-32, and 53-54
can be used as unlike
poles.
Only NC contacts 11-12,
21-22, and 31-32 have a
certified direct opening
mechanism.
The terminals 11-42,
21-22, 31-32, and 51-52
can be used as unlike
poles.
Lock position
Door open/
closed detection
Lock monitor
D4NL-□BF□-□
1NC/1NO + 2NC
11
33
Zb
12
34
41
51
Zb
42
52
11-42
33-34
51-52
Stroke
Operation
Key insertion
completion position
Extraction
completion
position
ON
Lock position
Door open/
closed detection
Lock monitor
D4NL-□CF□-□
2NC + 1NC/1NO
11
31
Zb
12
32
Zb
41
53
42
54
11-42
31-32
53-54
Stroke
Operation
Key insertion
completion position
Extraction
completion
position
ON
g
Lock position
Door open/
closed detection
Lock monitor
D4NL-□DF□-□
2NC + 2NC
Zb
11
31
12
32
41
51
Zb
42
52
11-42
31-32
51-52
Stroke
Operation
Key insertion
completion position
Extraction
completion
position
ON
Lock position
Door open/
closed detection
Lock monitor
Zb
Zb
12
22
34
41
53
42
54
D4NL-□EF□-□
2NC/1NO + 1NC/1NO
11
21
33
11-42
21-22
33-34
53-54
Stroke
Operation
Key insertion
completion position
Extraction
completion
position
ON
Lock position
Door open/
closed detection
Lock monitor
Zb
Zb
12
22
34
41
51
42
52
D4NL-□FF□-□
2NC/1NO + 2NC
11
21
33
11-42
21-22
33-34
51-52
Operation
Key insertion
completion position
ON
Stroke
Extraction
completion
position
Lock position
Door open/
closed detection
Lock monitor
D4NL-□GF□-□
3NC + 1NC/1NO
Zb
11
21
31
12
22
32
41
53
Zb
42
54
11-42
21-22
31-32
53-54
Operation
Key insertion
completion position
ON
Stroke
Extraction
completion
position
Lock position
Door open/
closed detection
Lock monitor
Zb
Zb
12
22
32
41
51
42
52
D4NL-□HF□-□
3NC + 2NC
11
21
31
11-42
21-22
31-32
51-52
Stroke
Operation
Key insertion
completion position
Extraction
completion
position
ON
OmrOn Scientific technOlOgieS, inc.
USA
Tel. 1/888/510-4357
canada
Tel. 1/866/986-6766
For the Latest Information
On the Internet:
www.sti.com
or
www.omron.ca
g65
D4nl
Safety interlock Switches
Dimensions and Operating characteristics
Switches
D4nl-□□□□-B
15.5
30.5
Pre-travel distance
8
(mm)
Red
Black
10.0
15.3
Four, head mounting screws
Operation Key
Three, 4.3-dia. holes
4
29
6.5
Operating
characteristics
Key insertion force
Key extraction
force
Pre-travel distance
movement before
being locked
D4nl-□□□□-
BS
15 N max.
30 N max.
9 mm max.
3 mm min.
28.5 4.4
Dummy cap
Indicator
UNLOCK
32
±0.2
6.5
29
0.5
59
(13.3)
LOCK
(55.8)
Five, cover
mounting screws
(32.3)
55
±0.2
(3)
(95)
4
0.5
35.5
5
Release key
(30.7)
(57.9)
79
±0.2
(88.5)
4.5
Conduit cap
Cap screw
29
6.5
(15.3)
g
(10)
UNLOCK
LOCK
Conduit opening
D4nl-□□□□-B4
15.5
30.5
8
Red
Pre-travel distance
Black
10.0
15.3
Four, head mounting screws
Operation Key
Three, 4.3-dia. holes
4
29
6.5
Operating
characteristics
Key insertion force
Key extraction force
Pre-travel distance
movement before
being locked
D4nl-□□□□-
B4
15 N max.
30 N max.
9 mm max.
3 mm min.
28.5 4.4
Dummy cap
Indicator
UNLOCK
32
±0.2
6.5
29
0.5
59
(13.3)
LOCK
(55.8)
Five, cover
mounting screws
(95)
(32.3)
55
±0.2
(3)
4
Cap screw
4.5
Conduit cap
29
6.5
(15.3)
0.5
35.5
5
M8 hexagonal material
or equivalent
8
21
Releasing tool
Release key
(provided)
10.5
(10)
(30.7)
(57.9)
79
±0.2
(88.5)
UNLOCK
LOCK
Conduit opening
Notes:
1. Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions.
2. There are fluctuations in the contact ON/OFF timing for Switches with multiple poles (2NC, 2NC/1NO, or 3NC). Confirm performance before application.
g66
OmrOn Scientific technOlOgieS, inc.
USA
Tel. 1/888/510-4357
canada
Tel. 1/866/986-6766
For the Latest Information
On the Internet:
www.sti.com
or
www.omron.ca
D4nl
Safety interlock Switches
Dimensions and Operating characteristics (continued)
D4nl-□□□□-BS
15.5
30.5
Pre-travel distance
8
(mm)
Red
Black
10.0
15.3
Four, head mounting screws
Operation Key
Three, 4.3-dia. holes
4
29
6.5
Operating
characteristics
Key insertion force
Key extraction
force
Pre-travel distance
movement before
being locked
D4nl-□□□□-
BS
15 N max.
30 N max.
9 mm max.
3 mm min.
28.5 4.4
Release key
Indicator
UNLOCK
32
±0.2
6.5
29
0.5
59
(13.3)
LOCK
(31.5)
(55.8)
Five, cover
mounting screws
(95)
(32.3)
55
±0.2
(3)
4
Cap screw
4.5
Conduit cap
29
6.5
(15.3)
0.5
35.5
5
Dummy cap
(30.7)
(57.9)
79
±0.2
(88.5)
UNLOCK
LOCK
Conduit opening
D4nl-□□□□-B4S
15.5
30.5
Pre-travel distance
8
g
15.3
Red
10.0
Four, head mounting screws
Operation Key
Three, 4.3-dia. holes
4
29
6.5
Black
28.5 4.4
Release key
Indicator
UNLOCK
Operating
characteristics
Key insertion force
Key extraction force
Pre-travel distance
movement before
being locked
D4nl-□□□□-
B4S
15 N max.
30 N max.
9 mm max.
3 mm min.
32
±0.2
6.5
29
0.5
59
(13.3)
LOCK
(31.5)
(55.8)
Five, cover
mounting screws
(30.7)
(57.9)
79
±0.2
(88.5)
(32.3)
55
±0.2
(3)
(95)
4
Cap screw
4.5
Conduit cap
29
6.5
(15.3)
0.5
35.5
5
Releasing tool
Dummy
(provided)
cap
10.5
21
M8 hexagonal material
or equivalent
8
Notes:
1. Unless otherwise specified, a tolerance
of ±0.4 mm applies to all dimensions.
2. There are fluctuations in the contact
ON/OFF timing for Switches with multiple
poles (2NC, 2NC/1NO, or 3NC). Confirm
performance before application.
UNLOCK
LOCK
Conduit opening
Operation Keys
D4DS-K1
7
30
15
7
Four, 2.15R
17.5
13
4.3
13
Black
28
D4DS-K3
14
4
28
8 dia.
4.5 dia.
9 dia.
Angle adjustment bolt
13
20°
2
6.3
15
28
2
30
40
56
D4DS-K2
9
30
28
6
10.5
7
15
7
Four, 2.15R
D4DS-K5
20.9
4
24.6
22.5
Mounting Holes
(Enlargement)
17
15
4.5
8
13
15°
43
13
Black
18°
41
30
55
41
43
2 4.3
6.5
18
(7)
OmrOn Scientific technOlOgieS, inc.
USA
Tel. 1/888/510-4357
canada
Tel. 1/866/986-6766
For the Latest Information
On the Internet:
www.sti.com
or
www.omron.ca
g67
D4nl
Safety interlock Switches
Dimensions and Operating characteristics (continued)
I would like to ask, when using the M5311 module for NB project, how is the communication encryption between the device and the ONENET platform done? I have read some materials and videos, but I can't...
I compiled the RDA example in "EVC Advanced Programming and Application Development" and downloaded it to PPC 2003 to run. When PULL, //Get the corresponding data from the server void CRDAExamDlg::OnB...
I just started using ISE, using V14.3. I found that no matter what I do, it is very slow. It takes half a day to open an IP core. Is it because the version is too high? . . . Because I have been using...
1 Introduction
The high temperature tester is mainly used for temperature tracking measurement and data acquisition during the heating process. By systematically analyzing the test data, the...[Details]
A standard cell
is an electrochemical
cell
used as a voltage reference standard in many electrical standards laboratories
. If properly maintained, standard cells are very stable. The ...[Details]
introduction
MEMS is a high-tech that has flourished on the basis of integrated circuit production technology and dedicated micro-electromechanical processing methods. Pressure sensors develop...[Details]
Today, with energy becoming increasingly scarce, the utilization of natural energy has become the focus of people's attention. Among various natural energies, the endless solar energy is highly fav...[Details]
0 Introduction
High-precision current source can provide high-precision current supply for precision instruments, and is suitable for automatic measurement tasks of various resistors in semico...[Details]
Direct digital frequency synthesis (DDS) has fast frequency switching and modulation capabilities and is widely used. However, when low power consumption and low cost are the main considerations, D...[Details]
1 Introduction
Automatic Test
System The ATS (Automatic Test System) integrates all the stimulus and measurement equipment required for testing.
The computer
efficiently comp...[Details]
Designing low power circuits while achieving acceptable performance is a difficult task. Doing so in
the RF
bands increases the challenge dramatically. Today, nearly everything has wireless...[Details]
TPMS is the abbreviation of "Tire Pressure Monitoring System". It is mainly used to automatically monitor the tire pressure in real time when the car is driving, and to alarm for tire leakage and l...[Details]
The battery and its management system are one of the key technologies of electric vehicles. In the past few years, most companies have encountered embarrassment in the development of electric vehic...[Details]
The cruise control system (CCS) of a vehicle is also called a constant speed driving system. It is an electronic control device that uses advanced electronic technology to automatically adjust the ...[Details]
As we all know, the manufacturing of modern automobiles is divided into four major processes: stamping, welding, painting and assembly, and the powertrain constitutes five inseparable production pr...[Details]
Since the implementation of the self-weight toll collection system, the highway administration has not only high requirements for the vehicle axle recognition rate, but also requires a long service li...[Details]
1. Don't say "Give me a code" as the first sentence when you see someone else's reply. You should think about why. When you figure it out yourself
and refer to other people
's
tips, you will...[Details]
No matter which processor you are learning, the first thing you need to understand is the registers and working mode of the processor.
ARM has 37 registers, including 31 general registers and ...[Details]