VKP60xTC
NOT RECOMMENDED
FOR NEW DESIGNS
RoHS Compliant
18 - 40 & 33 - 75V Input Range
Each Channel Independently Current
Limited
High Efficiency: 87% Typical
Excellent Cross Regulation
1500V
DC
Isolation Between Input
and Output
500 V
DC
Channel to Channel Isolation
Fixed Frequency Operation
60 Watt Triple Output
Half Brick DC/DC Converter
Operation to 100°C Baseplate
Temperature
50μS Transient Recovery,
0-90% Load Step
Primary & Secondary Remote On/Off
Adjustable Output Voltage
External Synchronization
VKP60MT Series UL/cUL approved
to UL1950 and VDE approved to
EN60950-1
ISO9001
CERTIFIED
For full details go to
www.murata-ps.com/rohs
The VKP60LTC and VKP60MTC Series are
members of the VK high density DC/DC converter
family. They are multiple output DC/DC convert-
ers offered in both a 18-40 and 33-75 input
voltage range. Their versatile architecture featur-
ing fully isolated channels enables the system
designer to utilize the converter in either a single,
dual or triple output scheme without excessive
minimum load requirements or cross regulation
degradation.
The VKP60xTC’s architecture results in an
economical and practical solution for use in dis-
tributed power schemes for today’s demanding
telecommunication and electronic data process-
ing applications requiring ground separation
between noise sensitive digital logic and bipolar
analog components. The VKP60xTC’s proprietary
control circuity responds to 50-100% load steps
in 35μSeconds to within 1% of nominal Vout.
The peak deviation will not exceed 7% of Vout
for pulsed load slew rates in excess of 75 Amps
per microsecond. The VKP60xTC is ideal for
electronic data processing applications utilizing
modern disk drives and low voltage micro-
processors that require dynamic load current
response while maintaining tight output voltage
tolerances.
PRODUCT SELECTION CHART
MODEL
VKP60LT312C
VKP60LT315C
VKP60LT512C
VKP60LT515C
VKP60MT312C
VKP60MT315C
VKP60MT512C
VKP60MT515C
INPUT
VOLTAGE
(V
DC
)
24 (18-40)
24 (18-40)
24 (18-40)
24 (18-40)
48 (33-75)
48 (33-75)
48 (33-75)
48 (33-75)
RATED V
OUT
(V
DC
)
V1 (±)
3.3
3.3
5.1
5.0
3.3
3.3
5.1
5.0
V2 (±)
12
15
12
15
12
15
12
15
V3 (±)
12
15
12
15
12
15
12
15
V1(±)
18
18
12
12
18
18
12
12
RATED MAXIMUM I
OUT
(A)
V2(±)
2.5
2.0
2.5
2.0
2.5
2.0
2.5
2.0
V3(±)
2.5
2.0
2.5
2.0
2.5
2.0
2.5
2.0
www.murata-ps.com
Technical inquiries
-
email:
sales@murata-ps.com,
tel:
508 339 3000
TDC_VKP60xTC.B01 Page 1 of 7
VKP60xTC
60 Watt Triple Output
Half Brick DC/DC Converter
SPECIFICATIONS, ALL MODELS
Specifications are at T
CASE
= +40°C nominal input voltage unless otherwise specified.
PARAMETER
Voltage Range
VKP60LTXXC Series
VKP60MTXXC Series
Reflected Ripple Current
Input Ripple Current
Maximum Input Current
VKP60LTXXC Series
VKP60MTXXC Series
No Load Power Dissipation
Inrush Charge
VKP60LTXXC Series
VKP60MTXXC Series
Quiescent Operating Current
Primary On/Off Disabled
Seconary On/Off Disabled
7.5
15
Peak - Peak
DC to 1KHz
Output Power = 60 W
V
IN
= 16V
V
IN
= 30V
P
OUT
= 0, V
IN MIN
< V
IN
< V
IN MAX
50
60
6
3
6
0.29
0.165
10
25
CONDITIONS
MIN
16
33
TYP
24
48
MAX
40
75
220
UNITS
V
DC
V
DC
mA
dB
A
A
W
mC
mC
mA
mA
INPUT
PARAMETER
ISOLATION
Input to Output
Input to Baseplate
Channel to Channel
Resistance, Input to Output
Capacitance, Input to Output
Leakage Current
GENERAL
Set-point Accuracy
Turn-on Time
Remote On/Off Control Inputs
Primary
Sink Current Logic Low
Vlow
Vhigh
Secondary
Sink Current Logic Low
Vlow
Vhigh
External Synchronization Input
Frequency
Pulse Width
Source Impedance
Input High Voltage
Input Low Voltage
Input Impedance
Switching Frequency
Weight
CONDITIONS
Peak Test
Any Channel to Channel
MIN
1500
1500
500
10
TYP
MAX
UNITS
V
DC
V
DC
V
DC
MΩ
2000
180
1
3.5
Open Collector/Drain
V
IN
= V
IN MAX
5
pF
oA, rms
%
mSec
GENERAL
24
48
7
0.8
Open Collector
100
0.4
Open Collector
mA
V
Open Collector/Drain
μA
V
440
150
4
0
470
470
480
520
320
47
5
1
490
3 (85)
KHz
nSec
Ω
V
V
Ω
KHz
oz (g)
* See Application Notes available on the web at www.murata-ps.com
** X = Either L (24) or M (48)
www.murata-ps.com
Technical inquiries
-
email:
sales@murata-ps.com,
tel:
508 339 3000
TDC_VKP60xTC.B01 Page 2 of 7
VKP60xTC
60 Watt Triple Output
Half Brick DC/DC Converter
SPECIFICATIONS, ALL MODELS
Specifications are at T
CASE
= +40°C nominal input voltage unless otherwise specified.
PARAMETER
CONDITIONS
Case temperature
-40
-50
+100
Case to Ambient
8.2
+100
+125
+115
˚C
˚C
˚C
˚C/W
MIN
TYP
MAX
UNITS
GENERAL
continued
TEMPERATURE
Operation/Specification
Storage
Shutdown
Thermal Impedance
PARAMETER
Output Power
CONDITIONS
Total Combined O/P Power =
60 Watts Max.
I
O Nom
V1
Min
Nom
30
3.3
9
100
.02
Max
60
18
200
3.80
.05
1.0
1.0
25
250
50
5.0
0
Min
V2
Nom
15
12.2
1.25
150
.02
Max
30
2.5
0
250
Dependent on V1
.05
Min
V3
Nom
15
12.2
1.25
150
.02
Max
30
2.5
250
.05
UNITS
W
V
A
mV
V
%/°C
%
%
A
A
mV
μSec
V
%
VKP60xT312C** OUTPUT
Set Point Voltage
Output Current, I
OUT
Output Ripple, p-p
Output Adjust Range
Output Temperature Drift
Line Regulation
Load Regulation
Current Limit Inception
Short-Circuit Current
Transient Response
Peak Deviation
Settling Time
Overvoltage Limit
Efficiency
0.5
DC to 20MHz
*
*
V
IN, Min
<V
IN
>V
IN, Max
I
O
= I
O, Nom
Min Load to Rated Load
Other Outputs Min Load
50 to 100% Load Step
V
OUT
, 1% of V
OUT
,
Nom
I
OUT1
=9A, (I
OUT2
+I
OUT3
)=2.5A
F.L. V
IN
=Nominal
3.15
0.05
0.50
23
19
150
35
4.2
85
86
1.0
2.0
See Regulation Curves
5.0
4.0
5.0
1.0
2.0
See Regulation Curves
5.0
4.0
5.0
PARAMETER
Output Power
Set Point Voltage
Output Current, I
OUT
Output Ripple, p-p
Output Adjust Range
Output Temperature Drift
Line Regulation
Load Regulation
Current Limit Inception
Short-Circuit Current
Transient Response
Peak Deviation
Settling Time
Overvoltage Limit
Efficiency
CONDITIONS
Total Combined O/P Power =
60 Watts Max.
I
O Nom
V1
Min
Nom
30
3.3
9
100
.02
Max
60
18
200
3.80
.05
1.0
1.0
25
250
50
5.0
0
Min
V2
Nom
15
15.85
1
125
Max
30
Min
V3
Nom
15
15.85
1
125
.02
Max
30
2
250
V
.05
UNITS
W
V
A
mV
%/°C
%
%
A
A
mV
μSec
V
%
VKP60xT315** OUTPUT
0.5
DC to 20MHz
*
See Application Notes
*
V
IN, Min
<V
IN
>V
IN, Max
I
O
= I
O, Nom
Min Load to Rated Load
Other Outputs Min Load
50 to 100% Load Step
V
OUT
, 1% of V
OUT, Nom
I
OUT1
=9A, (I
OUT2
+I
OUT3
)=2A
F.L. V
IN
=Nominal
4.2
85
3.15
2
0
250
Dependent on V1
.02
.05
0.05
0.50
23
19
150
35
86
1.0
2.0
See Regulation Curves
4.0
3.2
4.0
1.0
2.0
See Regulation Curves
4.0
3.2
4.0
* See Application Notes available on the web at www.murata-ps.com
** X = Either L (24) or M (48)
www.murata-ps.com
Technical inquiries
-
email:
sales@murata-ps.com,
tel:
508 339 3000
TDC_VKP60xTC.B01 Page 3 of 7
VKP60xTC
60 Watt Triple Output
Half Brick DC/DC Converter
SPECIFICATIONS, ALL MODELS
Specifications are at T
CASE
= +40°C nominal input voltage unless otherwise specified.
PARAMETER
Output Power
Set Point Voltage
Output Current, I
OUT
Output Ripple, p-p
Output Adjust Range
Output Temperature Drift
Line Regulation
Load Regulation
Current Limit Inception
Short-Circuit Current
Transient Response
Peak Deviation
Settling Time
Overvoltage Limit
Efficiency
CONDITIONS
Total Combind O/P Power =
60 Watts Max
I
O Nom
V1
Min
Nom
30
5.1
6.0
125
.02
Max
60
12
200
5.50
.05
0.10
1.0
16
300
50
6.8
0
Min
V2
Nom
15
12
1.25
150
Max
30
Min
V3
Nom
15
12
1.25
150
.02
Max
30
2.5
250
V
.05
UNITS
W
V
A
mV
%/°C
%
%
A
A
mV
μSec
V
%
VKP60xT512** OUTPUT
0.5
DC to 20MHz
*
*
V
IN, Min
<V
IN
>V
IN, Max
I
O
= I
O, Nom
Min Load to Rated Load
Other Outputs Min Load
50 to 100% Load Step
V
OUT
, 1% of V
OUT, Nom
I
OUT1
=6A, (I
OUT2
+I
OUT3
)=2.5A
F.L. V
IN
=Nomina
4.75
2.5
0
250
Dependent on V1
.02
.05
0.05
0.50
16
12.6
200
35
6.0
86
87
1.0
2.0
See Regulation Curves
5.0
4.0
5.0
1.0
2.0
See Regulation Curves
5.0
4.0
5.0
PARAMETER
Output Power
Set Point Voltage
Output Current, I
OUT
Output Ripple, p-p
Output Temperature Drift
Line Regulation
Load Regulation
Current Limit Inception
Short-Circuit Current
Transient Response
Peak Deviation
Settling Time
Overvoltage Limit
Efficiency
CONDITIONS
Total Combined O/P Power =
60 Watts Max
I
O Nom
V1
Min
Nom
30
5.0
6
100
4.60
.02
0.05
0.50
16
12.6
200
35
6.0
86
87
Max
60
12
200
.05
0.10
1.0
16
300
50
6.8
0
5.50
Min
V2
Nom
15
15.3
1
125
.02
Max
30
Min
V3
Nom
Max
30
2
250
V
.05
15
15.3
2
0
1
250
125
Dependent on V1
.05
.02
UNITS
W
V
A
mV
%/°C
%
%
A
A
mV
μSec
V
%
VKP60xT515** OUTPUT
0.5
DC to 20MHz
*
Output Adjust Range
V
IN, Min
<V
IN
>V
IN, Max
I
O
= I
O, Nom
Min Load to Rated Load
Other Outputs Min Load
50 to 100% Load Step
V
OUT
, 1% of V
OUT, Nom
I
OUT1
=6A, (I
OUT2
+I
OUT3
)=2A
F.L. V
IN
=Nominal
*
1.0
2.0
See Regulation Curves
4.0
3.2
4.0
1.0
2.0
See Regulation Curves
4.0
3.2
4.0
* See Application Notes available on the web at www.murata-ps.com
** X = Either L (24) or M (48)
VKp60
xTyz-
L
C
ORDERING INFORMATION
Device Family
Indicates 100 Watt Regulated Unit
Model Number
Selected from Table of Electrical Characteristics
Where:
x = Input Voltage (L = 24V
DC
, M = 48V
DC
)
T = Number of Outputs (Triple ‘T’)
y = 3 for 3.3V, 5 for 5V
z = 12 for 12V, 15 for 15V
Lead Length
0.250" - No Number
0.145" - (6)
0.110" - (8)
RoHS Compliant
www.murata-ps.com
Technical inquiries
-
email:
sales@murata-ps.com,
tel:
508 339 3000
TDC_VKP60xTC.B01 Page 4 of 7
VKP60xTC
60 Watt Triple Output
Half Brick DC/DC Converter
TYPICAL PERFORMANCE CURVES
Specifications are at T
CASE
= +40°C nominal input voltage, nominal load, recommended external components applied, unless otherwise specified.
(Refer to Application Note DCAN-9 at www.murata-ps.com)
EFFICIENCY vs TEMPERATURE
T
CASE
= +40°C, nominal input voltage, nominal load, recommended external
components applied, unless otherwise specified.*
ABSOLUTE MAX. RATINGS
Output Short-Circuit
Duration
Baseplate Temperature
Lead Temperature
(soldering, 10 seconds max)
Storage Temperature
Input to Output Isolation
Continuous
+100°C
+300°C
+125°C
1500 V
DC
Change in Efficiency (%)
Case Temperature (°C)
www.murata-ps.com
Technical inquiries
-
email:
sales@murata-ps.com,
tel:
508 339 3000
TDC_VKP60xTC.B01 Page 5 of 7