Corcom Product Guide
DC Feedthrough Filters – Class Y4
Catalog: 1654001
Issue Date: 08.2010
FFD Series
Component Recognized by
UL to US and Canadian Requirements
FFD Series
• DC feedthrough filters
• Current ratings from 10 to 200A
• Designed to meet the very stringent safety
requirements of EN133200 class Y4 including
the 2500V pulse test
• Custom versions available
Specifications
Rated Voltage (max):
Rated Current:
Test Voltage (two seconds):
Capacitor Class (EN133200):
Pulse Test (EN133200):
130 VDC
10 to 200A
2500 VDC
Designed to meet Y4
2500V Peak
Ordering Information
10 FFD6 – CA
Filter ID
See Table
FFD Series Screw Terminals
Current Rating
(in A)
Insulation Resistance (within 1 minute):
For C < 0.33µF, R> 15000MΩ
For C > 0.33µF, RC(MΩ*µF)>5000s
Operating Ambient Temperature Range
(at rated current Ir):
10 to 100A: -40°C to +60°C
200A: -40°C to +50°C
Category Temperature Range:
Current Derating Above Ambient:
10-100A: For temperature,
θ Iθ
=
IR
√(85-
θ
)/25
200A: For temperature,
θ Iθ
=
IR
√(85-
θ
)/35
Climatic Category:
MTBF:
40/85/21
> 5 million hours typical
UL94V-0
-40°C to +85°C
5
Feedthrough Filters and Capacitors
Filter Options / Specifications
Inductance
(nH)
70
80
140
90
120
180
240
330
DC
Resistance
(mΩ) Max.
6
3
8
2
1
3
2
2
Insulating Materials Flammability Rating:
Case & Terminal Material:
Nickel Plated Brass
Filter ID
CA
HB
HE
NC
ND
NH
PK
RP
Value (nF)
2 x 10
2 x 100
2 x 100
2 x 470
2 x 470
2 x 470
2 x 1000
2 x 4700
Electrical Schematic
231
Dimensions are in inches and millimeters unless otherwise specified. Values in italics
are metric equivalents. Dimensions are shown for reference purposes only.
Specifications subject to change.
For email, phone or live chat, please go to
tycoelectronics.com/help
corcom.com
Corcom Product Guide
DC Feedthrough Filters – Class Y4
(continued)
Catalog: 1654001
Issue Date: 08.2010
FFD Series
Case Style
Resin Fill
T1 (Terminal thread)
T2 (Mounting thread)
Case Dimensions
A
Part No.
10FFD6-CA
± .04
1
B
± .02
0.5
C
± .08
2
D
± .04
1
E
± .08
2
F
(max)
B
C
D
E
F
A
16FFD6-CA
32FFD6-CA
63FFD6-HB
T1 – Terminal Thread
Part No.
10FFD6-CA/HE
16FFD6-CA/HE
32FFD6-CA/HE
63FFD6-HB/NH
100FFD6-NC/PK
200FFD6-ND/RP
Thread
M3
M4
M6
M8
M10
Torque
max. in.lb.
4
11
22
44
70
100FFD6-NC
200FFD6-ND
10FFD6-HE
16FFD6-HE
32FFD6-HE
63FFD6-NH
100FFD6-PK
T2 – Mounting Thread
Part No.
10FFD6-CA/HE
16FFD6-CA/HE
32FFD6-CA/HE
63FFD6-HB/NH
Thread
M12 x 1
Torque
max. in.lb.
35
200FFD6-RP
3.54
90
3.86
98
6.30
160
7.24
184
8.23
209
5.12
130
5.47
139
6.81
173
8.98
173
10.98
279
0.79
20
0.79
20
0.98
25
1.26
32
1.50
38
0.79
20
0.79
20
1.26
32
1.50
32
2.13
54
1.93
49
2.09
53
3.70
94
4.09
104
4.41
112
3.50
89
3.70
94
4.13
105
5.71
105
7.17
182
0.47
12
0.47
12
0.55
14
0.63
16
0.75
19
0.47
12
0.47
12
0.63
16
0.75
16
0.75
19
0.63
16
0.71
18
1.02
26
1.26
32
1.57
40
0.63
16
0.71
18
1.02
26
1.26
26
1.57
40
0.67
17
0.67
17
0.87
22
1.06
27
1.06
27
0.67
17
0.67
17
1.06
27
1.06
27
1.57
40
M20 x 1
89
100FFD6-NC/PK
M24 x 1
124
200FFD6-ND/RP
M27 x 1.5
142
232
Dimensions are in inches and millimeters unless otherwise specified. Values in italics
are metric equivalents. Dimensions are shown for reference purposes only.
Specifications subject to change.
For email, phone or live chat, please go to
tycoelectronics.com/help
corcom.com
Corcom Product Guide
DC Feedthrough Filters – Class Y4
(continued)
Catalog: 1654001
Issue Date: 08.2010
FFD Series
Available Part Numbers
Standard Performance
10FFD6-CA
16FFD6-CA
32FFD6-CA
63FFD6-HB
100FFD6-NC
200FFD6-ND
High Performance
10FFD6-HE
16FFD6-HE
32FFD6-HE
63FFD6-NH
100FFD6-PK
200FFD6-RP
Performance Data
Typical Insertion Loss
Filter
ID
CA
HB
HE
NC
ND
NH
PK
RP
— Line to Ground in 50 Ohm circuit
Frequency – MHz
0.3
1
4
10
18
27
18
27
30
32
30
32
31
35
34
53
52
85
0.01
-
2
2
7
7
7
14
20
0.03
-
4
4
14
14
14
21
32
0.1
2
10
10
23
23
23
30
40
10
23
62
67
70
70
75
75
100
100
65
95
95
100
100
100
100
100
1000
100
100
100
100
100
100
100
100
5
Feedthrough Filters and Capacitors
233
Dimensions are in inches and millimeters unless otherwise specified. Values in italics
are metric equivalents. Dimensions are shown for reference purposes only.
Specifications subject to change.
For email, phone or live chat, please go to
tycoelectronics.com/help
corcom.com