EEWORLDEEWORLDEEWORLD

Part Number

Search

GLC50-28G

Description
Linear & switching power supply 50w 28v @ 1.8A
Categorysemiconductor    Power management   
File Size207KB,2 Pages
ManufacturerAll Sensors
Environmental Compliance
Download Datasheet Parametric View All

GLC50-28G Online Shopping

Suppliers Part Number Price MOQ In stock  
GLC50-28G - - View Buy Now

GLC50-28G Overview

Linear & switching power supply 50w 28v @ 1.8A

GLC50-28G Parametric

Parameter NameAttribute value
MakerAll Sensors
Product CategoryLinear vs. Switching Power Supplies
RoHSyes
productSwitching
Commercial/MedicalCommercial
Output power rating50 W
Input voltage90 VAC to 264 VAC
Number of outputs1
Output voltage (channel 1)28 V
Output current (channel 1)1.8 A
Installation styleChassis
open frame/closedOpen Frame
Output typeSingle Outpu
series connectionGLC
GLC50 Commercial/GLM50 Medical
50 WATT GLOBAL PERFORMANCE SWITCHERS
GLOBAL PERFORMANCE SWITCHERS
Features:
• Cost-effective power source
• Universal input 90-264 Vac
• 2-year warranty
• Compact (4.25” x 2.50” x 1.25”; meets
1U applications)
• Overload and overvoltage protection
• Conducted EMI exceeds FCC Class B and
CISPR 22 Class B (Commercial models) and
CISPR 11 Class B (Medical models)
• Commercial UL/CSA/IEC60950-1, EN60950 approvals
• Medical UL/EN/IEC60601-1, CSA22.2 No. 601,
• RoHS compliant models available (G suffix)
marked to LVD
SPECIFICATIONS
Ac Input
90-264 Vac, 47-63 Hz single phase..
Input Current
Maximum input current at 120 Vac, 60 Hz with full rated output load: 1.5 A
Hold-Up Time
15 ms minimum from loss of ac input at full load, nominal line (115 Vac).
Output Power
50 W continuous, 60 W peak. Peak ratings are for 60 s maximum duration,
10% duty cycle. During peak load condition, output regulation may exceed
total regulation limits.
Output Regulation
To maintain specified regulation on multi-output models, output #1 load
power must be at least 1/5th of, and not greater than 5 times output #2 load
power.
Overload Protection
Fully protected against short circuit and output overload. Short circuit pro-
tection is cycling type power limit on outputs 1 & 2; foldback type on output
3. Recovery after fault is automatic. See output ratings chart for additional
notes or conditions.
Efficiency
70-85% at full rated load, nominal input voltage, depending on model and
load distribution.
Minimum Load
Operating without minimum load will not degrade reliability, but regula-
tion may be affected. Multiple output models require 20% minimum load
on V1 for proper regulation. Single models require 5% minimum load when
a transient load greater than 30% is applied or removed, but will operate
without load.
Input Protection
Internal ac fuse provided. Designed to blow only if a catastrophic failure oc-
curs in the unit—fuse does not blow on overload or short circuit.
Inrush is limited by internal thermistors. Inrush at 240 Vac,
averaged over the first ac half-cycle under cold start
conditions will not exceed 37 A.
Temperature Coefficient
0.03%/°C typical on all outputs.
Output Noise
0.5% rms, 1% pk-pk, 20 MHz bandwidth, differential mode. Measured with noise
probe directly across output terminals of the power supply.
Transient Response
500 μs typical response time for return to within 0.5% of final value for a 50% load
step change. ∆i/∆t<0.2 A/μs. Maximum voltage deviation is 3.5%. Startup/shut-
down overshoot less than 3%.
Voltage Adjustment
Built-in potentiometer adjusts V1 ±5%.
EMI/EMC Compliance
All models include built-in EMI filtering to meet the following emissions require-
ments:
EMI SPECIFICATIONS
Conducted Emissions GLC
Conducted Emissions GLM
Static Discharge
RF Field Susceptibility
Fast Transients/Bursts
Surge Susceptibility
COMPLIANCE LEVEL
EN55022 Class B; FCC Class B
EN55011 Class B; FCC Class B
EN61000-4-2, 6 kV contact, 8 kV air
EN61000-4-3, 3 V/meter
EN61000-4-4, 2 kV, 5 kHz
EN61000-4-5, 1 kV diff., 2 kV com.
DC Power Supplies
Commercial Leakage Current
160 μA 254 Vac @ 60 Hz input (with no deviations).
Commercial Safety
All GLC models are approved to UL1950, CSA22.2 No.
234 Level 3, IEC950 and EN60950.
Medical Leakage Current
100 μA 264 Vac @ 60 Hz input (normal conditions).
Medical Safety
All GLM50 models are approved to UL/EN/IEC60601-1, CSA22.2 No. 601.
All specifications are typical at nominal input, full load at 25
O
C unless otherwise stated
Study Notes: GPIO Operation of TMS320C6748
1. GPIO characteristics of TMS320C6748 Referring to the 1.2Features section of the TI technical document SPRUFL8B (TMS320C674x/OMAP-L1x Processor GPIO User's Guide), we can see that the GPIO of the TM...
灞波儿奔 DSP and ARM Processors
xc866 experimental example
This is a screenshot on Docin, which took me a lot of time. Now I upload it to share with you. It is not very well done, so please just take a look at it....
LRXTL MCU
BLE Course (I): Bluetooth Low Energy Technology and Its Characteristics
[flash]http://v.youku.com/v_show/id_XNTk1OTI1Mzg0.html[/flash]Texas Instruments (TI) Bluetooth low energy devices for sensor applications are truly single-chip integrated solutions. Perfectly combined...
德州仪器_视频 Analogue and Mixed Signal
Serial communication can only output 3 characters
I wrote a serial port program that can receive and output, but when receiving more than 4 characters, garbled characters appear. I don't know if it is a setting problem or a program writing problem. C...
sunnyzeng1 Embedded System
The sensor is connected via Bluetooth and then reads the data from the mpu
...
liangtom125 onsemi and Avnet IoT Innovation Design Competition
Can't use ST-LINK on keil4! ! Can anyone help me figure out how to solve this problem?
I downloaded the MDK3.32 version before, but it didn't work when I used STLINK to download it, so I downloaded the new MDK4.12 version. As a result, the following prompt appeared during the download:o...
jiuzhouliujun stm32/stm8

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 702  199  2254  2427  860  15  5  46  49  18 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号