EEWORLDEEWORLDEEWORLD

Part Number

Search

FMXMB1118IDE-03.200000M-TD

Description
Quartz Crystal,
CategoryPassive components    Crystal/resonator   
File Size260KB,1 Pages
ManufacturerFrequency Management International
Environmental Compliance
Download Datasheet Parametric View All

FMXMB1118IDE-03.200000M-TD Overview

Quartz Crystal,

FMXMB1118IDE-03.200000M-TD Parametric

Parameter NameAttribute value
Is it Rohs certified?conform to
Objectid145048858423
package instructionHC-49/US, 2 PIN
Reach Compliance Codecompliant
Ageing5 PPM/YEAR
Crystal/Resonator TypePARALLEL - FUNDAMENTAL
Drive level50 µW
frequency stability0.001%
frequency tolerance40 ppm
load capacitance18 pF
Installation featuresTHROUGH HOLE MOUNT
Nominal operating frequency3.2 MHz
Maximum operating temperature60 °C
Minimum operating temperature-10 °C
physical sizeL11.5XB4.65XH4.1 (mm)/L0.453XB0.183XH0.161 (inch)
Series resistance180 Ω
surface mountNO
FMXMB
SERIES
Thru-hole Crystals
Low Profile
Thru-Hole Package
Multiple Package Heights
Low Cost
HC-49/US
SPECIFICATIONS
Issue 6 - 10182012
Parameter
Frequency Range
Operation Mode
Load Capacitance (CL)
Frequency Tolerance
Temperature Tolerance
Operating Temperature
Storage Temperature
Equivalent Series Resistance (ESR)
Shunt Capacitance (C0)
Drive Level
Aging @ 25°C
All specifications subject to change without notice.
Specification
3.2 - 90 MHz
See Operation Mode and ESR Table
18 pF Std., 8 - 60 pF and Series available
±30 ppm @ 25°C Std. (See Cal. Tol. for Options)
±50 ppm Std. (See Temp. Tol. for Options)
0 to +70°C Std. (See Temp. Range for Options)
-55 to +125°C
See Operation Mode and ESR Table
7 pF max.
50 uW typical, 1 mW max.
±5 ppm per year max.
HC-49/US
OPERATION MODE AND ESR TABLE
Frequency (MHz)
3.200 - 5.999
6.000 - 7.999
8.000 - 9.999
10.00 - 14.99
15.000 - 40.000
27.000 - 70.000
MODE
Fundamental
Fundamental
Fundamental
Fundamental
Fundamental
3
rd
Overtone
MAX ESR (Ohms)
180
100
70
60
40
120
DIMENSION “H” TABLE
STANDARD MARKING
FMI XX.XXX
XX.XXX FREQUENCY in MHz
Package
B1
B2
B3
Max. Height
0.161” (4.1mm)
0.126” (3.2mm)
0.118” (3.0mm)
NOTE: Standard Specifications for product indicated in
color
Dimensions:
Inches
(mm)
PART DESCRIPTION SYSTEM
MARKING: See Page 52, Format A
FMXM B1 1 18 H J A - XX.XXXXXXM - CM
Product Family
Crystal
Package
B1,
B2 or B3
Mode
1 - Fundamental
3 - 3rd Overtone
Load Cap. (CL)
18 - Standard (pF)
00 - Series
## - Custom (pF)
Cal.
D
E
F
G
H
I
J
X
Tol. @ 25°C
±10 ppm
±15 ppm
±20 ppm
±25 ppm
±30 ppm
±40 ppm
±50 ppm
Custom
*Temp. Tol.
D ±10 ppm
E ±15 ppm
F ±20 ppm
G ±25 ppm
H ±30 ppm
I ±40 ppm
J ± 50 ppm
X Custom
Frequency (MHz)
Temp. Range
**
A 0 to 70 °C
B -20 to 70 °C
C -40 to 85 °C
D -10 to 50 °C
E -10 to 60 °C
F -30 to 60 °C
J 0 to 50 °C
X Custom
Options
BI - Base Insulator
LT - Lead Trimming
LF - Lead Forming
PD - Parameter Data
TD - Temp. Data
CM - Custom Mark
BLANK - None Req’d.
**Check with us for availability.
-55°C TO +125°C Available, Limited Stability Options,
please consult the factory.
1-800-800-XTAL
[9825]
www.fmi-inc.com
11
These are interview questions for a mobile software company. Can you help me do them?
7. How many of the below are FALSE about constants? I.They may occur on the left of :=( := 赋值 ) II.They may occur on the left of =( = 比较 ) III. They may occur on the right of := IV.They may occur on t...
jp19848 Embedded System
The use and differences between CODE and DATA
I would like to ask what is the difference between the following two program segments, the functions should be the same, but I don’t know if there is any difference? Also, under what circumstances is ...
cyllouis Embedded System
Analysis of the winning work of Huang Zhiwei of the 2011 D topic LC resonant amplifier from the University of South China
[i=s] This post was last edited by paulhyde on 2014-9-15 03:00 [/i] [color=#000000][b][font=宋体][size=14pt]Huang Zhiwei from the University of South China [/size][/font] Analysis of the winning works o...
黄智伟 Electronics Design Contest
[Help] Easy ARM2200 uses D12 module and the command cannot be sent
When I use Easy ARM2200 and D12 to connect for USB testing, why when I use the outportd function to send data to D12, the correct value appears on the eight-bit data line of D12, but when I use the ou...
wangku001wei ARM Technology
What is this error?
Sat Oct 30, 2021 10:39:43: Failed to write chunk with size 128 at address 0x8000: SWIM PROG error [42006]: Error getting prog statusWhat is this error? IAR STM8, burning an empty program also reports ...
zhang520 stm32/stm8
Question about timer
I use the timer to start the AD conversion. I would like to ask if the timer continues to count after the AD interrupt service subroutine is started, or does it start counting after the interrupt serv...
neckfully Analogue and Mixed Signal

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2704  935  847  2593  152  55  19  18  53  4 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号