THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT
ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT
www.vishay.com/doc?91000
80D
www.vishay.com
Vishay Sprague
NOMINAL CASE SIZE
DxL
1.18 x 1.38 (30.0 x 35.0)
1.38 x 1.38 (35.0 x 35.0)
1.18 x 1.97 (30.0 x 50.0)
1.38 x 1.97 (35.0 x 50.0)
0.984 x 1.57 (25.0 x 40.0)
1.18 x 1.18 (30.0 x 30.0)
1.18 x 1.57 (30.0 x 40.0)
1.18 x 1.97 (30.0 x 50.0)
0.984 x 1.18 (25.0 x 30.0)
1.18 x 1.18 (30.0 x 30.0)
1.38 x 1.18 (35.0 x 30.0)
1.18 x 1.97 (30.0 x 50.0)
1.38 x 1.97 (35.0 x 50.0)
0.984 x 1.18 (25.0 x 30.0)
1.18 x 1.18 (30.0 x 30.0)
0.984 x 1.97 (25.0 x 50.0)
1.18 x 1.97 (30.0 x 50.0)
1.38 x 1.97 (35.0 x 50.0)
0.984 x 0.984 (25.0 x 25.0)
1.18 x 0.984 (30.0 x 25.0)
1.18 x 1.38 (30.0 x 35.0)
1.18 x 1.57 (30.0 x 40.0)
1.18 x 1.57 (30.0 x 40.0)
1.38 x 1.97 (35.0 x 50.0)
1.38 x 1.97 (35.0 x 50.0)
1.38 x 1.97 (35.0 x 50.0)
0.984 x 0.984 (25.0 x 25.0)
0.984 x 1.18 (25.0 x 30.0)
0.984 x 1.57 (25.0 x 40.0)
0.984 x 1.97 (25.0 x 50.0)
1.18 x 1.97 (30.0 x 50.0)
1.38 x 1.97 (35.0 x 50.0)
MAX. ESR (m)
MAX. RIPPLE AT +85 °C (A)
10 kHz TO 40 kHz
4.2
7.2
7.2
10.0
4.9
3.6
4.9
6.1
3.8
3.9
6.6
6.4
10.0
3.5
3.7
5.9
6.2
6.2
3.2
3.6
4.9
5.7
4.7
7.4
6.6
6.6
3.2
3.8
5.2
6.3
7.0
7.4
ELECTRICAL DATA AND ORDERING INFORMATION
CAPACITANCE (μF)
PART NUMBER
120 Hz 10 kHz TO 40 kHz 120 Hz
60.0
33.0
33.0
20.0
57.0
79.0
51.0
40.0
82.0
72.0
40.0
36.0
21.0
139.0
111.0
68.0
55.0
50.0
660.0
460.0
278.0
220.0
248.0
130.0
144.0
141.0
720.0
541.0
343.0
263.0
185.0
191.0
51.0
27.0
27.0
17.0
42.0
63.0
41.0
32.0
55.0
54.0
28.0
28.0
15.0
85.0
74.0
42.0
37.0
37.0
375.0
272.0
165.0
131.0
127.0
82.0
81.0
75.0
377.0
284.0
182.0
140.0
101.0
81.0
3.8
6.2
6.2
8.8
3.9
3.1
4.3
5.3
2.8
3.2
5.0
5.4
8.3
2.2
2.7
3.9
4.7
5.2
1.3
1.7
2.4
2.8
2.1
4.3
3.4
3.4
1.1
1.4
2.0
2.5
3.2
4.0
35 WV
DC
AT +85 °C, SURGE = 44 V
6800.0
10 000.0
12 000.0
15 000.0
3300.0
3300.0
4700.0
6800.0
1500.0
2200.0
3300.0
4700.0
6800.0
680.0
1000.0
1500.0
2200.0
3300.0
150.0
220.0
330.0
470.0
680.0
820.0
1000.0
1200.0
100.0
150.0
220.0
330.0
470.0
680.0
Statements about product lifetime are based on calculations and internal testing. They should only be interpreted as estimations. Also due to external factors, the
lifetime in the field application may deviate from the calculated lifetime. In general, nothing stated herein shall be construed as a guarantee of durability.
80D682P035KC2DE3
80D103P035MC2DE3
80D123P035KE2DE3
80D153P035ME2DE3
80D332P050JD2DE3
80D332P050KB2DE3
80D472P050KD2DE3
80D682P050KE2DE3
80D152P063JB2DE3
80D222P063KB2DE3
80D332P063MB2DE3
80D472P063KE2DE3
80D682P063ME2DE3
80D681P100JB2DE3
80D102P100KB2DE3
80D152P100JE2DE3
80D222P100KE2DE3
80D332P100ME2DE3
80D151P200JA2DE3
80D221P200KA2DE3
80D331P200KC2DE3
80D471P200KD2DE3
80D681P200KD2DE3
80D821P200ME2DE3
80D102P200ME2DE3
80D122P200ME2DE3
80D101P250JA2DE3
80D151P250JB2DE3
80D221P250JD2DE3
80D331P250JE2DE3
80D471P250KE2DE3
80D681P250ME2DE3
50 WV
DC
AT +85 °C, SURGE = 63 V
63 WV
DC
AT +85 °C, SURGE = 79 V
100 WV
DC
AT +85 °C, SURGE = 125 V
200 WV
DC
AT +85 °C, SURGE = 250 V
250 WV
DC
AT +85 °C, SURGE = 300 V
Revision: 20-Jul-16
Document Number: 42060
3
For technical questions, contact:
aluminumcaps4@vishay.com
THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT
ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT
www.vishay.com/doc?91000
Legal Disclaimer Notice
www.vishay.com
Vishay
Disclaimer
ALL PRODUCT, PRODUCT SPECIFICATIONS AND DATA ARE SUBJECT TO CHANGE WITHOUT NOTICE TO IMPROVE
RELIABILITY, FUNCTION OR DESIGN OR OTHERWISE.
Vishay Intertechnology, Inc., its affiliates, agents, and employees, and all persons acting on its or their behalf (collectively,
“Vishay”), disclaim any and all liability for any errors, inaccuracies or incompleteness contained in any datasheet or in any other
disclosure relating to any product.
Vishay makes no warranty, representation or guarantee regarding the suitability of the products for any particular purpose or
the continuing production of any product. To the maximum extent permitted by applicable law, Vishay disclaims (i) any and all
liability arising out of the application or use of any product, (ii) any and all liability, including without limitation special,
consequential or incidental damages, and (iii) any and all implied warranties, including warranties of fitness for particular
purpose, non-infringement and merchantability.
Statements regarding the suitability of products for certain types of applications are based on Vishay’s knowledge of
typical requirements that are often placed on Vishay products in generic applications. Such statements are not binding
statements about the suitability of products for a particular application. It is the customer’s responsibility to validate that a
particular product with the properties described in the product specification is suitable for use in a particular application.
Parameters provided in datasheets and / or specifications may vary in different applications and performance may vary over
time. All operating parameters, including typical parameters, must be validated for each customer application by the customer’s
technical experts. Product specifications do not expand or otherwise modify Vishay’s terms and conditions of purchase,
including but not limited to the warranty expressed therein.
Except as expressly indicated in writing, Vishay products are not designed for use in medical, life-saving, or life-sustaining
applications or for any other application in which the failure of the Vishay product could result in personal injury or death.
Customers using or selling Vishay products not expressly indicated for use in such applications do so at their own risk.
Please contact authorized Vishay personnel to obtain written terms and conditions regarding products designed for
such applications.
No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this document
or by any conduct of Vishay. Product names and markings noted herein may be trademarks of their respective owners.
When using PIC16F73, when performing port operations, using statements like PORTC=0xff to output high and low levels on the I/O port, PORTC works very well, but after the operation on PORTB, a level t...
Reprinted from [url]http://www.eepw.com.cn/article/268232.htm[/url] [size=14px]The instruction set can be divided into two parts: complex instruction set (CISC) and reduced instruction set (RISC). The...
First of all, this PSoC4 Pioneer Kit, brand new, unopened, 100 RMB... Specific pictures: [url=http://item.taobao.com/item.htm?spm=a1z10.1.w137644-1358093687.40.LegaAx&id=37737189404]http://item.taobao...
I have a stupid question.If I write a multiplication program in C language,for example: a=b*c,how does this instruction run in the microcontroller? Is it doneby the hardware multiplier configured on t...
As a natural human-machine interface, voice can make the in-vehicle navigation system safer and more user-friendly. Through the functional comparison of domestic and foreign in-vehicle navigation s...[Details]
Ultrasonic tooth cleaning machines have been widely used in the medical field. Most ultrasonic tooth cleaning machines used at home and abroad now use analog oscillation circuits. There are the follow...[Details]
This article introduces a miniature home electrocardiograph. The instrument has powerful functions: display monitoring, storage, playback, printing, record management, power alarm, telephone or Intern...[Details]
Obtaining real-time and reliable traffic information has always been a bottleneck problem in the development of intelligent transportation systems. The establishment of an intelligent transportatio...[Details]
The hardware circuit principle is shown in Figure 1. In the specific design, each part should consider the anti-interference problem to minimize the impact of interference on the performance of the...[Details]
Emulation Features
Emulation provides a set of standard operations for integration and debugging. Some of its main features are as follows:
BreakpointsA
common feature of emulatio...[Details]
As the whole equipment is becoming increasingly miniaturized and power-saving, low-dropout linear regulators (LDOs) with low power consumption are becoming the mainstream in the market for linear regu...[Details]
Portable devices with audio functions (such as portable media players and multimedia mobile phones) require long audio playback time, that is, long battery life. To extend the battery life of port...[Details]
Signal sources have developed to a very wide range today. We can classify them according to the frequency range: ultra-low frequency (0.1m~1kHz), audio (20Hz~20kHz), video (20kHz~10MHz), radio fre...[Details]
1 Introduction
The intelligent meter reading system is a system that reads the data of multiple user meters in a centralized manner through the transmission media by the master station. It...[Details]
introduction
Controller Area Network (CAN) is a bus standard proposed by Bosch of Germany to solve the information communication between automotive electronic control units. With its exc...[Details]
In a Class D audio power amplifier, the preamplifier is a relatively important module. It is located at the front of the entire topology and completes the processing of the input signal source,...[Details]
With the continuous emergence of new technologies and the increasing complexity of DSP real-time systems, there are more and more different types of external devices. Writing drivers for these exte...[Details]
1. Introduction
Rolling bearings are the most widely used general mechanical components in various rotating machines. Whether their operating status is normal often directly affects the perfo...[Details]
Introduction
As a kind of biometric identification, fingerprint recognition has incomparable advantages in identity recognition over other means: human fingerprints are unique and stable; wit...[Details]