EEWORLDEEWORLDEEWORLD

Part Number

Search

ADE7761BARS

Description
energy metering IC with On-chip fault and missing neutral detection
CategoryAnalog mixed-signal IC    The signal circuit   
File Size431KB,24 Pages
ManufacturerADI
Websitehttps://www.analog.com
Download Datasheet Parametric Compare View All

ADE7761BARS Overview

energy metering IC with On-chip fault and missing neutral detection

ADE7761BARS Parametric

Parameter NameAttribute value
Is it Rohs certified?incompatible
MakerADI
Parts packaging codeSSOP
package instructionMO-150AE, SSOP-20
Contacts20
Reach Compliance Codenot_compliant
ECCN codeEAR99
Analog Integrated Circuits - Other TypesANALOG CIRCUIT
JESD-30 codeR-PDSO-G20
JESD-609 codee0
length7.2 mm
Humidity sensitivity level1
Number of functions1
Number of terminals20
Maximum operating temperature85 °C
Minimum operating temperature-40 °C
Package body materialPLASTIC/EPOXY
encapsulated codeSSOP
Encapsulate equivalent codeSSOP20,.3
Package shapeRECTANGULAR
Package formSMALL OUTLINE, SHRINK PITCH
power supply5 V
Certification statusNot Qualified
Maximum seat height2 mm
Maximum supply current (Isup)3.6 mA
Maximum supply voltage (Vsup)5.25 V
Minimum supply voltage (Vsup)4.75 V
Nominal supply voltage (Vsup)5 V
surface mountYES
Temperature levelINDUSTRIAL
Terminal surfaceTin/Lead (Sn85Pb15)
Terminal formGULL WING
Terminal pitch0.65 mm
Terminal locationDUAL
width5.3 mm
Base Number Matches1
Energy Metering IC with On-Chip Fault and
Missing Neutral Detection
ADE7761B
FEATURES
High accuracy, active energy measurement IC supports
IEC 62053-21
Less than 0.1% error over a dynamic range of 1000 to 1
Supplies active power on the frequency outputs, F1 and F2
High frequency output CF is intended for calibration and
supplies instantaneous active power
Continuous monitoring of the phase and neutral current
allows fault detection in 2-wire distribution systems
Current channel input level best suited for shunt and current
transformer sensors
Uses the larger of the two currents (phase or neutral) to bill,
even during a fault condition
Continuous monitoring of the voltage and current inputs
allows missing neutral detection
Uses one current input (phase or neutral) to bill when
missing neutral is detected
Two logic outputs (FAULT and REVP) can be used to indicate
a potential miswiring, fault, or missing neutral condition
Direct drive for electromechanical counters and 2-phase
stepper motors (F1 and F2)
Proprietary ADCs and DSP provide high accuracy over large
variations in environmental conditions and time
Reference 2.5 V ± 8% (drift 30 ppm/°C typical) with external
overdrive capability
Single 5 V supply, low power
GENERAL DESCRIPTION
The ADE7761B is a high accuracy, fault-tolerant, electrical energy
measurement IC intended for use with 2-wire distribution systems.
The part specifications surpass the accuracy requirements as
quoted in the IEC 62053-21 standard. The only analog circuitry
used on the ADE7761B is in the ADCs and reference circuit.
All other signal processing (such as multiplication and filtering)
is carried out in the digital domain. This approach provides
superior stability and accuracy over extremes in environmental
conditions and over time. The ADE7761B incorporates a fault
detection scheme similar to the
ADE7751
by continuously
monitoring both phase and neutral currents. A fault is indicated
when the currents differ by more than 6.25%.
The ADE7761B incorporates a missing neutral detection scheme
by continuously monitoring the input voltage. When a missing
neutral condition is detected (no voltage input), the ADE7761B
continues billing based on the active current signal (see the
Missing Neutral Mode section). The missing neutral condition
is indicated when the FAULT pin goes high. The ADE7761B
supplies average active power information on the low frequency
outputs, F1 and F2. The CF logic output gives instantaneous
active power information.
The ADE7761B includes a power supply monitoring circuit on
the V
DD
supply pin. Internal phase matching circuitry ensures
that the voltage and current channels are matched. An internal
no-load threshold ensures that the ADE7761B does not exhibit
any creep when there is no load.
FAULT
15
FUNCTIONAL BLOCK DIAGRAM
PGA
13
AGND
8
V
DD
1
POWER
SUPPLY MONITOR
V
1A 2
V
1N 4
V
1B 3
MISCAL
7
V
2P 6
V
2N 5
ADC
B>A
A
B
ZERO-CROSSING
DETECTION
MISSING NEUTRAL
GAIN ADJUST
ADC
A>B
HPF
ADE7761B
SIGNAL PROCESSING
BLOCK
LPF
ADC
ADC
3kΩ
2.5V
REFERENCE
9
MISSING NEUTRAL
DETECTION
INTERNAL
OSCILLATOR
14
17
DIGITAL-TO-FREQUENCY CONVERTER
06797-001
10
11
12
16
18
19
20
REF
IN/OUT
RCLKIN
DGND
SCF
S1
S0 REVP CF
F2
F1
Figure 1.
Rev. 0
Information furnished by Analog Devices is believed to be accurate and reliable. However, no
responsibility is assumed by Analog Devices for its use, nor for any infringements of patents or other
rights of third parties that may result from its use. Specifications subject to change without notice. No
license is granted by implication or otherwise under any patent or patent rights of Analog Devices.
Trademarks and registered trademarks are the property of their respective owners.
One Technology Way, P.O. Box 9106, Norwood, MA 02062-9106, U.S.A.
Tel: 781.329.4700
www.analog.com
Fax: 781.461.3113
©2007 Analog Devices, Inc. All rights reserved.

ADE7761BARS Related Products

ADE7761BARS ADE7761B ADE7761BARS-REF ADE7761BARS-RL
Description energy metering IC with On-chip fault and missing neutral detection energy metering IC with On-chip fault and missing neutral detection energy metering IC with On-chip fault and missing neutral detection energy metering IC with On-chip fault and missing neutral detection
How to write GPIB control software using VB
I would like to ask how to use VB to control the operation and reading and writing of the device through GPIB. I have no idea now. I hope experts can recommend some information or source code for me t...
zdk Embedded System
Find the Verilog code for serial-to-parallel conversion
I am working on a 16QAM modulator recently. The first step is to achieve serial-to-parallel conversion? My understanding is that a string of digital signals is input , and each time eight bits are sel...
江南爵爷 FPGA/CPLD
MFC program cannot run on wince
I would like to ask you: I created an MFC Smart Device Application in VS2005, selected Dialog Based, used static libraries, and supported ActiveX controls. 1: Without modifying any code, I directly pu...
chuhui Embedded System
Wince drawing problem!
Experts, I have a program that can save as a BMP file on XP, but now I want to port it to WINCE, but WINCE does not support GetDIBits. Can anyone help me replace it with CreateDIBSection? The function...
dltskp Embedded System
Renesas group purchase activity is about to start, please pay attention
Good news must be notified to everyone in advance, :loveliness: The Renesas DIY event has ended successfully, and the Renesas group purchase event is about to start. It is relatively easy to get a ver...
苏莎莎 Renesas Electronics MCUs
RealViewMDK3.24 evaluation version has been officially released, welcome to upgrade!
Software size: 99.14MDownload address: http://www.realview.com.cn/down-list.asp?id=584Note : For the Chinese version of MDK routine service package, please go to http://www.realview.com.cn/down-list.a...
lijiamin11 stm32/stm8

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1852  291  2403  571  2345  38  6  49  12  48 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号