EEWORLDEEWORLDEEWORLD

Part Number

Search

2641LHC7/127000LI

Description
Rocker Switch, On-off, 10A, 24VDC, Screw Terminal, Rocker Actuator, Panel Mount
CategoryMechanical and electronic products    switch   
File Size333KB,8 Pages
ManufacturerAPEM
Download Datasheet Parametric View All

2641LHC7/127000LI Overview

Rocker Switch, On-off, 10A, 24VDC, Screw Terminal, Rocker Actuator, Panel Mount

2641LHC7/127000LI Parametric

Parameter NameAttribute value
Objectid312981385
Reach Compliance Codecompliant
Country Of OriginUK
ECCN codeEAR99
YTEOL9.1
Actuator colorWHITE
Actuator length0.354 inch
Actuator materialPOLYAMIDE
Actuator typeROCKER
body width24.9936 mm
body height16.9926 mm
Body length or diameter32.004 mm
center contact materialCOPPER
Center contact platingSILVER
Contact (AC) maximum rated power R load0.16HP@250VAC
Contact (AC) maximum rated R load10A@250VAC
Maximum contact current (AC)10 A
Maximum contact current (DC)10 A
Contact (DC) maximum rated R load10A@24VDC
Contact functionON-OFF
Contact resistance0.01 mΩ
Maximum contact voltage (AC)250 V
Maximum contact voltage (DC)24 V
Dielectric withstand voltage2500VRMS V
Electrical life10000 Cycle(s)
End contact materialCOPPER
End contact platingSILVER
Shell materialPOLYAMIDE
Insulation resistance1000000000 Ω
Manufacturer's serial number2600
Installation featuresPANEL MOUNT
Maximum operating temperature55 °C
Minimum operating temperature-10 °C
surface mountNO
Switch typeROCKER SWITCH
Terminal length0.437 inch
Termination typeSCREW
2600 series
Power rocker switches
Distinctive features and specifications
Three rocker shapes : plain, V-shaped or concave
Various rocker colours
Frame with protection guard on 2600LP models
Illuminated or non-illuminated
UL, CSA, VDE and NF (EN 61058-1) approved
ELECTRICAL SPECIFICATIONS
• Max. current/voltage rating with resistive load and approved ratings : see table below.
• Initial contact resistance : 10mΩ max.
• Insulation resistance : 1.000 MΩ min. at 500VDC
• Dielectric strength : 2.500 Vrms 50 Hz min. between terminals
3.000 Vrms 50 Hz min. between terminals and metal panel
• Electrical life : 10.000 cycles at full load
APPROVED RATINGS
FUNCTIONS
CSA (double pole)
CSA 22-2
DIRECT CURRENT
NF
EN 61058-1
UL (double pole)
UL 1054
VDE
EN 61058-1
24 VDC
12 VDC
D
ON - OFF
ON - ON
1/6 HP 125VAC
16A 125VAC
16A 250VAC
1/3 HP 250VAC
10A 125VAC
10A 250VAC
1/6 HP 125/250VAC
-
10A 125VAC
10A 250VAC
1/6 HP 250VAC
1/6 HP 125VAC
16A 125VAC
16A 250VAC
1/3 HP 250VAC
10A 125VAC
10A 250VAC
1/6 HP 125/250VAC
-
-
10(4)A 250VAC
T 85/55
-
10A
15A
ON - OFF - ON
ON - ON - ON
OTHERS
L I option
10(4)A 250VAC
-
L I option
10(4)A 250VAC
L I option
10(4)A 250VAC
-
L I option
10(4)A 250VAC
8A
5A
8A
10A
8A
10A
MATERIALS
GENERAL SPECIFICATIONS
• Case : melamine/polyester
• Frame : polyamide
• Actuator : polyamide
• Contacts :
A
: silver
C
: copper, silver plated
• Panel thickness : 0,8 mm to 4 mm (.031 to .157)
• Operating temperature :
- silver contacts (A) : -20°C to +85°C
- silver plated contacts (C) : -10°C to +55°C
AGENCY APPROVALS
EN 61058-1
EN 61058-1
Availability
: consult factory for details of approved models.
Marking
: approved models are standard marked.
APEM
www.apem.com
D-45
Should DVB-H use L-Band or UHF band? .pdf
Should DVB-H use the L-Band or UHF band? The following article will give you a different view....
JasonYoo Test/Measurement
Classic: Ten Steps of SMT
Classic: Ten Steps of SMT...
fighting Industrial Control Electronics
About the problem of baud rate mismatch during USART communication
[font=微软雅黑][size=4] When sending data to the serial assistant through the USART serial port of CC2530, due to a step of carelessness, the baud rate was set incorrectly. However, stable data was obtain...
Taurus_Xp MCU
Giant's 30.5 billion acquisition of a gaming company was suddenly suspended due to a major matter investigation
[align=left][color=#000][font=Arial, Verdana, sans-serif][size=13.3333px][font=宋体][size=4] The deal of Great Network to acquire Israeli game technology company Playtika for 30.5 billion yuan suddenly ...
tlyl18108837711 Integrated technical exchanges
LPC2214 driver problem for K9F2808U0C
The MCU I use is LPC2214, the external FLASH is K9F2808U0C, and the FLASH is driven by IO analog control signals . There is no JTAG debugging port (really failed), and the data is written by the seria...
dianzijie5 ARM Technology
How to save power on mechanical watches←Power Saving Wizard
How to save electricity with mechanical meter ← Power Saving Wizard C card prepaid meter controller ※ Meter reversal QQ: 272208552 Tel: 13115998303 How to make the card meter go backwards, [If the web...
ji123yun Embedded System

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2253  185  1756  1935  685  46  4  36  39  14 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号