EEWORLDEEWORLDEEWORLD

Part Number

Search

2647LHA81901L220V1

Description
Rocker Switch, (on)-off-(on), Momentary, 8A, 24VDC, Screw Terminal, Rocker Actuator, Panel Mount
CategoryMechanical and electronic products    switch   
File Size333KB,8 Pages
ManufacturerAPEM
Download Datasheet Parametric View All

2647LHA81901L220V1 Overview

Rocker Switch, (on)-off-(on), Momentary, 8A, 24VDC, Screw Terminal, Rocker Actuator, Panel Mount

2647LHA81901L220V1 Parametric

Parameter NameAttribute value
Objectid313034550
Reach Compliance Codecompliant
Country Of OriginUK
ECCN codeEAR99
YTEOL9.1
Actuator colorORANGE
Actuator length0.354 inch
Actuator materialPOLYAMIDE
Actuator typeROCKER
Other features220VAC FLUORESCENT LAMP
body width24.9936 mm
body height16.9926 mm
Body length or diameter32.004 mm
center contact materialSILVER
Contact (AC) maximum rated power R load0.16HP@250VAC
Contact (AC) maximum rated R load10A@250VAC
Maximum contact current (AC)10 A
Maximum contact current (DC)8 A
Contact (DC) maximum rated R load8A@24VDC
Contact function(ON)-OFF-(ON)
Contact resistance0.01 mΩ
Maximum contact voltage (AC)250 V
Maximum contact voltage (DC)24 V
Dielectric withstand voltage2500VRMS V
Electrical life10000 Cycle(s)
End contact materialSILVER
Shell materialPOLYAMIDE
Insulation resistance1000000000 Ω
Manufacturer's serial number2600
Installation featuresPANEL MOUNT
Maximum operating temperature85 °C
Minimum operating temperature-20 °C
surface mountNO
Switch actionMOMENTARY
Switch typeROCKER SWITCH
Terminal length0.437 inch
Termination typeSCREW
2600 series
Power rocker switches
Distinctive features and specifications
Three rocker shapes : plain, V-shaped or concave
Various rocker colours
Frame with protection guard on 2600LP models
Illuminated or non-illuminated
UL, CSA, VDE and NF (EN 61058-1) approved
ELECTRICAL SPECIFICATIONS
• Max. current/voltage rating with resistive load and approved ratings : see table below.
• Initial contact resistance : 10mΩ max.
• Insulation resistance : 1.000 MΩ min. at 500VDC
• Dielectric strength : 2.500 Vrms 50 Hz min. between terminals
3.000 Vrms 50 Hz min. between terminals and metal panel
• Electrical life : 10.000 cycles at full load
APPROVED RATINGS
FUNCTIONS
CSA (double pole)
CSA 22-2
DIRECT CURRENT
NF
EN 61058-1
UL (double pole)
UL 1054
VDE
EN 61058-1
24 VDC
12 VDC
D
ON - OFF
ON - ON
1/6 HP 125VAC
16A 125VAC
16A 250VAC
1/3 HP 250VAC
10A 125VAC
10A 250VAC
1/6 HP 125/250VAC
-
10A 125VAC
10A 250VAC
1/6 HP 250VAC
1/6 HP 125VAC
16A 125VAC
16A 250VAC
1/3 HP 250VAC
10A 125VAC
10A 250VAC
1/6 HP 125/250VAC
-
-
10(4)A 250VAC
T 85/55
-
10A
15A
ON - OFF - ON
ON - ON - ON
OTHERS
L I option
10(4)A 250VAC
-
L I option
10(4)A 250VAC
L I option
10(4)A 250VAC
-
L I option
10(4)A 250VAC
8A
5A
8A
10A
8A
10A
MATERIALS
GENERAL SPECIFICATIONS
• Case : melamine/polyester
• Frame : polyamide
• Actuator : polyamide
• Contacts :
A
: silver
C
: copper, silver plated
• Panel thickness : 0,8 mm to 4 mm (.031 to .157)
• Operating temperature :
- silver contacts (A) : -20°C to +85°C
- silver plated contacts (C) : -10°C to +55°C
AGENCY APPROVALS
EN 61058-1
EN 61058-1
Availability
: consult factory for details of approved models.
Marking
: approved models are standard marked.
APEM
www.apem.com
D-45
Weak pull-up, open-drain output, push-pull output and Schmitt input of microcontroller IO port
Weak pull-up: A relatively weak pull-up, generally used in communication with peripheral devices, such as the IIC bus, but cannot be used in pull-up applications that require driving capability. When ...
siuhiong 51mcu
Those who know IBMR40E can read this
My computer has 256GB of RAM. I want to expand it to 1GB. It's too far to go to the computer market to install it. I bought a 512GB and a 256GB memory and planned to install it myself, but I can't fin...
zyw_124 Embedded System
Learning Edition Tutorial Lesson 12 IIC Bus
The last lesson, the IIC bus tutorial~...
youki12345 Integrated technical exchanges
How to convert force into digital display PCB board
My company is designing a product that converts the test force into a digital display, and then controls the entire circuit with a resistor or capacitor sensing button. After obtaining the data, it ca...
chj000 PCB Design
Regarding high voltage transmission, I have a vague question
Every time I take a car on the highway, I can see the high-voltage power transmission towers on both sides of the highway. The transmission lines on the towers are not of the same thickness. The line ...
小瑞 Industrial Control Electronics
coprocessor, help!
I am looking at coprocessor stuff. There are two instructions, MCR and MRC, which require the coprocessor's opcode. I have been looking for the opcode definition in the datasheet for a long time but c...
roMoon ARM Technology

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2675  189  2133  877  1840  54  4  43  18  38 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号