Description
cir brkr thrm 1.8A 250vac 48vdc
CategoryCircuit protection    Circuit protection   
File Size336KB,4 Pages
ManufacturerE-T-A [E-T-A Circuit Breakers]
Download Datasheet Parametric View All

106-M2-P30-1.8A Overview

cir brkr thrm 1.8A 250vac 48vdc

106-M2-P30-1.8A Parametric

Parameter NameAttribute value
Is it lead-free?Lead free
MakerE-T-A [E-T-A Circuit Breakers]
Reach Compliance Codecompli
Circuit protection typeTHERMAL CIRCUIT BREAKER
Thermal Overcurrent Circuit Breakers 104/105/106-...
Description
Miniaturised single pole thermal circuit breaker with push-to-reset,
tease-free, trip-free, snap action mechanism (R-type TO CBE to EN
60934). Available in versions for PCB or panel mounting, snap-in or
threadneck, or as an integral type. Approved to CBE standard EN
60934 (IEC 60934). For higher current ratings see type 1140.
Typical applications
Motors, transformers, solenoids, printed circuit boards, hand-held
machines and appliances, marine applications, caravans.
Ordering information
Type No.
104
PCB mounting type (-PR), or integral type (-P30/P10)
105
snap-in panel mounting
106
threadneck panel mounting with hex and knurled nut (hardware
bulk shipped with 5 pcs plus)
106-M2
threadneck panel mounting 3/8-27UNS with collar, hex nut and
knurled nut (hardware bulk shipped with 5 pcs plus)
Terminal design
P10
blade terminals A6.3-0.8 (QC .250)
P30
blade terminals A2.8-0.8 (QC .110)
PR
solder terminal pins for PCB mounting (type 104 only)
PR3
PCB mounting (vertical), type 104 only
Current ratings
0.05...10 A
106
-
P30 - 5 A
ordering example
104-...
Technical data
105-...
106-...
2
The exact part number required can be built up from the table of choices shown
above. Ordering references for optional features should be omitted if not required.
Preferred types
Preferred types Standard current ratings (A)
0.5 0.8 1 1.2 1.5 2
106-P10-
106-P30-
x
x
x
x
x
x
x
x
x
x
x
x
3
x
x
4
x
x
5
x
x
6
x
x
8
x
x
10
x
x
Standard current ratings and typical internal resistance values
Current
rating (A)
0.05
0.08
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
1
1.2
1.5
Internal
resistance (Ω)
285
134
81
22
8.7
5.5
3.3
2.45
1.6
1.45
0.9
0.6
0.4
Current
rating (A)
1.8
2
2.5
3
3.5
4
4.5
5
6
7
8
10
Internal
resistance (Ω)
0.28
0.25
0.18
0.11
0.076
0.067
0.051
≤ 0.05
≤ 0.05
≤ 0.05
≤ 0.05
≤ 0.05
For further details please see chapter: Technical Information
Voltage rating
AC 240 V; DC 48 V
(UL: AC 250 V; DC 48 V)
Current ratings
0.05...10 A
Auxiliary circuit
0.5 A, AC 240 V, DC 28 V
Typical life
0.05...5 A 1,000 operations at 2 x I
N
, inductive
DC 28 V: 3,000 operations at 2 x I
N
, inductive
6...8 A
500 operations at 2 x I
N
, inductive
10 A
50 operations at 2 x I
N
, inductive
Ambient temperature
-20...+60 °C (-4...+140 °F) T 60
Insulation co-ordination
rated impulse
pollution
(IEC 60664 and 60664 A) withstand voltage
degree
2.5 kV
2
reinforced insulation in operating area
Dielectric strength
test voltage
(IEC 60664 and 60664A)
operating area
AC 3,000 V
Insulation resistance
> 100 MΩ (DC 500 V)
Interrupting capacity I
cn
0.05...8 A
6 x I
N
AC
0.05...10 A 6 x I
N
DC
Interrupting capacity
I
N
U
N
(UL 1077)
0.05...10 A
AC 250 V
2,000 A
0.05...10 A
DC 48 V
200 A
Degree of protection
operating area IP40
(IEC 60529/DIN 40050)
terminal area IP00
Vibration
10 g (57-500 Hz) ± 0.76 mm (10-57 Hz),
to IEC 60068-2-6, test Fc,
10 frequency cycles/axis
Shock
25 g (11 ms) to IEC 60068-2-27, test Ea
Corrosion
96 hours at 5 % salt mist,
to IEC 60068-2-11, test Ka
Humidity
240 hours at 95 % RH,
to IEC 60068-2-78, test Cab
Mass
approx. 10 g
Approvals
Authority
VDE /SEV
UL
CSA
CQC
Standard
IEC/EN 60934
UL1077
C22.2 No 235
GB 17701
Rated voltage
AC 240 V
DC 48 V
AC 250 V
DC 48 V
AC 250 V
DC 48 V
AC 240 V
DC 48 V
Current ratings
0.02 A… 8 A
0.02 A…10 A
0.05 A…10 A
0.05 A…10 A
0.05 A…10 A
0.05 A…10 A
0.05 A…8 A
0.05 A…10 A
2015/16
www.e-t-a.de
2
- 15
What is the relationship between TAPI and TSPI in CE6.0? Is there a one-to-one correspondence? How does TAPI call TSPI? How is TSPI executed?
What is the relationship between TAPI and TSPI in CE6.0? Is there a one-to-one correspondence? How does TAPI call TSPI? How is TSPI executed?...
hozamon Embedded System
Do I need to add a pull-down resistor to the GPIO of STM32?
In the past, I mainly used 51 and lpc microcontrollers. This is my first time designing a STM32 microcontroller circuit. Based on previous experience, I designed it to absorb current. But after the PC...
bigbat stm32/stm8
How to set up APN in Windows?
I bought a mobile data card with a bound IP (10.14.170.108) and an APN network named dyshl.sd. I use a saro 3100 gprs modem. How can I set it up in windows 2003 so that I can use this fixed IP to acce...
stingxing Embedded System
P89LPC912 MCU Data Sheet
P89LPC912 is a microcontroller packaged in a single-chip package, suitable for many occasions requiring high integration and low cost. It can meet many performance requirements. P89LPC912 uses a high-...
rain MCU
5G has been commercially available for more than a year. Have you felt it?
It feels like the battle for 5G is still just around the corner, but before I knew it, I realized that 5G has been commercially available for more than a year.Netizens, have you felt the benefits of 5...
okhxyyo RF/Wirelessly
How to set the input buffer of MScomm?
I am writing something that uses the MSComm control of VC++6.0 for communication. I found that the size of the received data is different when the size is set. For example: In the case of self-transmi...
huhongfeng Embedded System

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1072  2408  2644  1236  317  22  49  54  25  7 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号