1627A
1626A
output
I
Connect two supplies in parallel to double the current
I
Connect two supplies in series to double the voltage
I
Fully overload protected
I
Great regulation
I
Low ripple
I
Coarse and fine voltage controls
I
Constant voltage or constant current operation
output
I
New compact style
I
Reliable, Durable
I
Operate continuously at full load without overheating
I
Continuously monitor voltage and current output on two
meters
Specifications
1620A
Output Voltage
Output Current
Constant Voltage
Operation
Voltage Regulation
Line (120VAC +10%, -6%)
Load (no load - full load)
Recovery Time
Ripple & Noise
Temperature Coefficient
Constant Current Operation
Adjustable Current Range
Current Regulation
Line (120VAC +10%, -6%)
Load
Current Ripple
Metering
Type
Voltmeter Range
Voltmeter Accuracy
Ammeter Range
Ammeter Accuracy
Overload Protection
Power Requirements
Power Consumption
Operating Temperature
Storage Temperature
Dimensions (HxWxD)
Weight
13.2 lbs. (6 kg)
Analog
0-18V
±7% FS
0-5 A
±7% FS
3-digit LED
0-18V
±2% + 2 digits
0-9.99 A
±2% +2 digits
0-18V
0-5A
1621A
0-18 V
0-5A
1622A
0-60 V
0-1.5 A
1623A
0-60 V
0-1.5 A
1626A
0-30 V
0-3 A
m
odels
1627A
0-30 V
0-3 A
<0.02% + 3mV
<0.02% + 3mV
<500ms
<1mVrms
<300ppm/˚C
0-100%
<0.02% + 3mA
<0.02% + 3mA
<3mA
Analog
0-60V
±7% FS
0-3 A
±7% FS
3-digit LED
0-60V
±2% +2 digits
0-9.99 A
±2% =2 digits
Analog
0-30V
±7% FS
0-3 A
±7% FS
3-digit LED
0-30V
±2% +2 digits
0-9.99 A
±2% +2 digits
Current, limiting, reverse polarity, overvoltage, short circuit
120VAC ±10%, 60Hz (120/220/230/24CVAC ±10%, 50/60Hz version available)
210W
220W
210W
32° to 104°F (0˚ to 40˚C), <75% R.H.
5° to 158°F (-15° to +70°C), <85% R.H.
8.07 x 4.53 x 10.63" (205 x 115 x 270 mm)
16.3 lbs. (7.4 kg)
13.2 lbs. (6 kg)
16.3 lbs. (7.4 kg)
13.2 lbs. (6 kg)
16.3 lbs. (7.4 kg)
220W
210W
220W
Accessories
OPTIONAL: Hook-up leads
up to 5 amps Model TL-5A
up to 30 amps Model TL-30
One Year W
arranty