EEWORLDEEWORLDEEWORLD

Part Number

Search

15SRB8-S

Description
Power line filter 15a wire-leaded
CategoryThe connector   
File Size656KB,5 Pages
ManufacturerAll Sensors
Environmental Compliance
Download Datasheet Parametric View All

15SRB8-S Online Shopping

Suppliers Part Number Price MOQ In stock  
15SRB8-S - - View Buy Now

15SRB8-S Overview

Power line filter 15a wire-leaded

15SRB8-S Parametric

Parameter NameAttribute value
MakerAll Sensors
Product CategoryPower line filter
RoHSyes
Voltage rating250 VAC
Current rating15 A
Installation styleFlange
Termination typeSolde
filter typeEMI/RFI Power Line
frequency50Hz, 60 Hz
Leakage current33.2 uA
productPower Line Filters
series connectionSRB
Corcom Product Guide
Catalog: 1654001
Issue Date: 08.2010
Minimum Depth, Cost-effective Shielded Power Inlet Filter
SRB Series
SRBP
UL Recognized
CSA Certified
VDE Approved*
SRBS8
SRB1
SRB2
SRB Series
• Smallest depth Corcom RFI filter available
• Complete shield
• Wide range of capacitor values
• Attenuates coupled EMI up to 300MHz
• Minimal to low leakage current versions are
suitable for patient and non-patient contact
medical equipment.
• Full range of mounting and termination options
including unique vertical and horizontal
orientation slide in mounts eliminate the need for
mounting hardware
Specifications
Maximum leakage current each Line to Ground:
@120 VAC
@250 VAC
Capacitor ID / Value
60 Hz
50 Hz
Blank / None
2
µA
5
µA
Q / 33 pF
2.1
µA
3.65
µA
R / 100 pF
9.6
µA
16.6
µA
S / 220 pF
19.2
µA
33.2
µA
T / 330 pF
24.0
µA
41.5
µA
W / 470 pF
0.04 mA
0.07 mA
X / 1000 pF
0.07 mA
0.13 mA
Y / 2200 pF
0.16 mA
0.28 mA
Z / 3300 pF
0.24mA
0.42 mA
Hipot rating (one minute):
Line to Ground:
Line to Line:
Rated Voltage (max.):
2250 VDC
1450 VDC
250 VAC
50/60 Hz
15A*
3
Power Inlet Filters & Power Entry Modules
Ordering Information
15 SRB S 1 - Q
Capacitor ID
See Chart
Omit if none
Output Styles
1 – Spade terminals
(back)
2 – Spade terminals
(bottom)
8 – Wire leads
P – PC board pins
Mounting Style
S – Snap-in
X – Slide-in (
short edge / horizontal)
Y – Slide-in (
long edge / vertical)
Omit for flange mount
SRB Series
Current Rating
15A
*15A versions are tested by Underwriters Laboratories
to US and Canadian requirements and are
VDE approved at 10A, 250VAC
Operating Frequency:
Rated Current:
Operating Ambient Temperature Range
(at rated current Ir):
-10°C to +40°C
In an ambient temperature (Ta) higher than +40°C
the maximum operating current (Io) is calculated as
follows: Io = Ir
√(85-Ta)/45
Capacitor Options
Capacitor ID
Q
R
S
T
W
X
Y*
Z*
Capacitor Value
33 pF
100 pF
220 pF
330 pF
470 pF
1000 pF
2200 pF
3300 pF
*Not available in SRB8, SRBX or SRBY styles
203
Dimensions are in inches and millimeters unless otherwise specified. Values in italics
are metric equivalents. Dimensions are shown for reference purposes only.
Specifications subject to change.
For email, phone or live chat, please go to
tycoelectronics.com/help
corcom.com
Compile Error in FPGA
Error: Tcl error: package "rtl" isn't loaded statically What is this error? Can't find a solution online? Thanks! :)...
水木秋寒 FPGA/CPLD
Why can't MSP430AD and DA work at the same time?
[table=98%] [tr][td][float=right] [url=http://ad-apac.doubleclick.net/jump/N3736.EEWORLD/B2649702.6;sz=100x250][img]http://ad-apac.doubleclick.net/ad/N3736.EEWORLD/B2649702.6;sz=100x250[/img][/url][/f...
Mr.ma Microcontroller MCU
mc39i startup problem
I would like to ask how to judge whether the GPRS module MC39I has been started? I made an ARM board that uses the GPRS module MC39I to access the Internet. The voltage of the MC39I vdd pin is 2.99V, ...
babaluosha Embedded System
How long have you not spent the Lantern Festival at home?
After graduating from school, I basically stay away from home, and I only spend about ten days at home every year. It has been more than ten years since I spent the Lantern Festival at home. How about...
采样电阻 Talking
Why *** error 65: access violation at C:0x0A00 : no 'execute/read' permission
As the title says, when I execute the main program to the end number }, there is always this error, that address is empty, what's going on?...
manbuzhe Embedded System
[Beetle ESP32-C3 Review] Part 2: vscode+idf+oled running through
[i=s]This post was last edited by lingxin_yuhe on 2022-8-24 10:29[/i]Preface: I have built the VScode+idf development environment. Later, I want to make a small demo of real-time time and weather disp...
lingxin_yuhe RF/Wirelessly

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1476  2317  2188  518  1576  30  47  45  11  32 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号