Note: The actual product is marked differently from the
image shown here.
■
Application Examples
•
Semiconductor test equipment
•
Test & Measurement equipment
•
Communication equipment
•
Data loggers
■
Terminal Arrangement/Internal
Connections
4
3
Mold pin
mark
*
OMRON logo
Pin 1 mark
1
2
932
Model name
LOT.No.
Note: The actual product is marked differently from the image shown here.
*
The indentation in the corner diagonally opposite from the pin 1 mark is from
a pin on the mold.
■
List of Models
Package type Contact form
SOP4
1a
(SPST-NO)
Terminals
Surface-mounting Terminals
Load voltage
(peak value)
*
80 V
Model
G3VM-81G1
G3VM-81G1 (TR)
Minimum package quantity
Number per tube Number per tape and reel
100
-
-
2,500
*
The AC peak and DC value are given for the load voltage.
■
Absolute Maximum Ratings
(Ta = 25°C)
Item
LED forward current
LED forward current reduction rate
LED reverse voltage
Connection temperature
Load voltage (AC peak/DC)
Continuous load current (AC peak/DC)
ON current reduction rate
Connection temperature
Dielectric strength between
I/O (See note 1.)
Ambient operating temperature
Ambient storage temperature
Soldering temperature
Output
Input
Symbol
I
F
∆I
F
/°C
V
R
T
J
V
OFF
I
O
∆I
O
/°C
T
J
V
I-O
Ta
Tstg
-
Rating
50
−0.5
5
125
80
350
−3.5
125
1500
−20
to +85
−40
to +125
260
Unit
mA
mA/°C
V
°C
V
mA
mA/°C
°C
Vrms
°C
°C
°C
Measurement conditions
Ta
≥
25°C
Ta
≥
25°C
AC for 1 min
With no icing or condensation
With no icing or condensation
10 s
Note: 1. The dielectric strength between the input and
output was checked by applying voltage
between all pins as a group on the LED side and
all pins as a group on the light-receiving side.
■
Electrical Characteristics
(Ta = 25°C)
Item
Symbol Minimum Typical Maximum
LED forward voltage
V
F
1.0
1.15
1.3
Reverse current
I
R
-
-
10
Capacity between terminals
C
T
-
15
-
Trigger LED forward current
I
FT
-
1.0
4.0
Maximum resistance with output ON
R
ON
-
1.0
1.2
Current leakage when the relay is open
I
LEAK
-
0.2
1.0
Capacity between terminals
Coff
-
30
40
Capacity between I/O terminals
C
I-O
-
0.8
-
Insulation resistance between I/O terminals
R
I-O
1000
-
-
Turn-ON time
t
ON
-
0.3
0.5
Turn-OFF time
t
OFF
-
0.3
0.5
Output
Input
Unit
V
µA
pF
mA
Ω
nA
pF
pF
MΩ
ms
ms
Measurement conditions
I
F
= 10 mA
Note: 2. Turn-ON and Turn-OFF Times
V
R
= 5 V
I
F
1
4 R
L
V
DD
V = 0, f = 1 MHz
V
OUT
2
3
I
O
= 350 mA
I
F
= 5 mA, I
O
= 350 mA
V
OFF
= 30 V, Ta = 50
°C
V = 0, f = 100 MHz
I
F
f = 1 MHz, V
S
= 0 V
V
I-O
= 500 VDC, R
O
H
≤
60 %
90%
V
OUT
10%
I
F
= 5 mA, R
L
= 200
Ω,
t
ON
t
OFF
V
DD
= 20 V (See note 2.)
1
G3VM-81G1
■
Recommended Operating Conditions
Use the G3VM under the following conditions so that the Relay will operate properly.
Item
Load voltage (AC peak/DC)
Operating LED forward current
Continuous load current (AC peak/DC)
Ambient operating temperature
Symbol
V
DD
I
F
I
O
Ta
Minimum
-
5
-
25
Typical
-
-
-
-
Maximum
64
30
350
60
Unit
V
mA
mA
°C
MOS FET Relays
■
Engineering Data
LED forward current vs. Ambient
temperature
I
F
- Ta
Continuous load current I
O
(mA)
LED forward current I
F
(mA)
100
700
600
Continuous load current vs. Ambient
temperature
I
O
- Ta
LED forward current vs. LED forward
voltage
I
F
- V
F
LED forward current I
F
(mA)
100
Ta = 25
°C
30
80
500
400
300
10
60
3
40
1
200
100
0.3
20
0
-20
0
20
40
60
80
100
120
0
-20
0.1
0
20
40
60
80
100
120
0.6
0.8
1
1.2
1.4
1.6
1.8
Ambient temperature Ta (°C)
Ambient temperature Ta (°C)
LED forward voltage V
F
(V)
Continuous load current vs. On-state
voltage
I
O
- V
ON
Continuous load current I
O
(mA)
400
Ta = 25
°C
I
F
= 5 mA
On-state resistance vs. Ambient
temperature
R
ON
- Ta
On-state resistance R
ON
(Ω)
I
O
= 350 mA
IO = 500 mA
I
F
= 5 mA
IF = 5 mA
t < 1s
Trigger LED forward current vs.
Ambient temperature
I
FT
- Ta
Trigger LED forward current I
FT
(mA)
5
I
O
= 350 mA
t < 1s
2
1.6
4
200
1.2
3
0
0.8
2
-200
0.4
1
-400
-0.5
-0.25
0
0.25
0.5
0
-20
0
0
20
40
60
80
100
-20
0
20
40
60
80
100
On-state voltage V
ON
(V)
Ambient temperature Ta (°C)
Ambient temperature Ta (°C)
Turn ON, Turn OFF time vs. LED
forward current
t
ON
, t
OFF
- I
F
Turn ON, Turn OFF time t
ON
, t
OFF
(µs)
5000
3000
t
ON
1000
500
300
t
OFF
100
50
30
Ta = 25
°C
V
DD
= 20 V
R
L
= 200
Ω
Turn ON, Turn OFF time vs. Ambient
temperature
t
ON
, t
OFF
- Ta
Turn ON, Turn OFF time t
ON
, t
OFF
(µs)
3000
V
DD
= 20 V
R
L
= 200
Ω
I
F
= 5 mA
1000
500
300
t
ON
5000
Current leakage vs. Ambient
temperature
I
LEAK
- Ta
Current leakage I
LEAK
(pA)
10000
3000
1000
300
100
50
30
t
OFF
100
V
OFF
= 80 V
30
V
OFF
= 50 V
V
OFF
= 30 V
10
1
5
10
50
100
500 1000
10
-20
10
0
20
40
60
80
100
-20
0
20
40
60
80
LED forward current I
F
(mA)
Ambient temperature Ta (°C)
Ambient temperature Ta (°C)
■
Safety Precautions
•
Refer to
"Common Precautions"
for all G3VM models.
2
Appearance/Dimensions
■
Appearance
SOP (Small Outline Package)
SOP4
SOP4 type
Mold pin mark
*
OMRON logo
Pin 1 mark
932
Model name
LOT.No.
Note: The actual product is marked differently from the image shown here.
*
The indentation in the corner diagonally opposite from the pin 1 mark is from a pin on the mold.
■
Dimensions
Surface-mounting Terminals
Weight: 0.1 g
4.4
±0.25
(Unit: mm)
Actual Mounting Pad
Dimensions
(Recommended Value, TOP VIEW)
3.9
±0.2
2.1 max.
0.15
6 to 6.3
1.2
0.4
±0.1
2.54
±0.25
Note: The actual product is marked differently from the image shown here.
0.1
±0.1
0.6
±0.3
7.0
±0.4
0.8
2.54
•
Application examples provided in this document are for reference only. In actual applications, confirm equipment functions and safety before using the product.
•
Consult your OMRON representative before using the product under conditions which are not described in the manual or applying the product to nuclear control systems, railroad
systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment, and other systems or equipment that may have a serious
influence on lives and property if used improperly. Make sure that the ratings and performance characteristics of the product provide a margin of safety for the system or
equipment, and be sure to provide the system or equipment with double safety mechanisms.
Note: Do not use this document to operate the Unit.