EEWORLDEEWORLDEEWORLD

Part Number

Search

CWR06MB224KB/PR

Description
CAPACITOR, TANTALUM, SOLID, POLARIZED, 35 V, 0.22 uF, SURFACE MOUNT, 1005, CHIP, ROHS COMPLIANT
CategoryPassive components    capacitor   
File Size314KB,21 Pages
ManufacturerVishay
Websitehttp://www.vishay.com
Environmental Compliance
Download Datasheet Parametric View All

CWR06MB224KB/PR Overview

CAPACITOR, TANTALUM, SOLID, POLARIZED, 35 V, 0.22 uF, SURFACE MOUNT, 1005, CHIP, ROHS COMPLIANT

CWR06MB224KB/PR Parametric

Parameter NameAttribute value
Is it Rohs certified?conform to
Objectid1096925812
package instruction, 1005
Reach Compliance Codecompliant
Country Of OriginIsrael
ECCN codeEAR99
YTEOL7.52
capacitance0.22 µF
Capacitor typeTANTALUM CAPACITOR
dielectric materialsTANTALUM (DRY/SOLID)
ESR24000 mΩ
high1.27 mm
JESD-609 codee4
leakage current0.001 mA
length2.54 mm
Installation featuresSURFACE MOUNT
negative tolerance10%
Number of terminals2
Maximum operating temperature125 °C
Minimum operating temperature-55 °C
Package shapeRECTANGULAR PACKAGE
Package formSMT
method of packingTR, EMBOSSED PLASTIC, 7 INCH
polarityPOLARIZED
positive tolerance10%
Rated (DC) voltage (URdc)35 V
GuidelineMIL-PRF-55365/4
size code1005
surface mountYES
Delta tangent0.06
Terminal surfaceGold (Au) - with Nickel (Ni) barrier
Terminal shapeWRAPAROUND
width1.27 mm
CWR06
www.vishay.com
Vishay Sprague
Solid Tantalum Surface Mount Capacitors T
ANTAMOUNT
Conformal Coated, Military MIL-PRF-55365/4 Qualified
FEATURES
• Weibull failure rates B, C, D, T
Exponential failure rates M, P, R, S
Available
• Tape and reel available per EIA 481
• Termination finishes available: gold plate,
Available
solder plated, solder fused and hot solder
dipped
• Material categorization: for definitions of compliance
please see
www.vishay.com/doc?99912
Note
*
This datasheet provides information about parts that are
RoHS-compliant and / or parts that are non RoHS-compliant. For
example, parts with lead (Pb) terminations are not RoHS-compliant.
Please see the information / tables in this datasheet for details
PERFORMANCE CHARACTERISTICS
www.vishay.com/doc?40211
Operating Temperature:
-55 °C to +125 °C
(above 85 °C, voltage derating is required)
Capacitance Range:
0.10 μF to 100 μF
Capacitance Tolerance:
± 5 %, ± 10 %, ± 20 %
Voltage Rating:
4 V
DC
to 50 V
DC
Moisture Sensitivity Level 1
ORDERING INFORMATION
CWR06
TYPE
D
VOLTAGE
B
TERMINATION
FINISH
B = gold
C = hot solder
dipped
H = solder
plated
K = solder
fused
155
CAPACITANCE
K
CAPACITANCE
TOLERANCE
J=±5%
K = ± 10 %
M = ± 20 %
B
FAILURE RATE
%/1000 h
M = 1.0
P = 0.1
R = 0.01
S = 0.001
B = 0.1
C = 0.01
D = 0.001
(1)
T = 0.01
(2)
A
SURGE CURRENT
(OPTIONAL)
Blank = no surge
A = 10 cycles at +25 °C
B = 10 cycles at -55 °C
and +85 °C
C = 10 cycles at -55 °C
and +85 °C
(before Weibull grading)
/TR
PACKAGING
(3)
C=4V
D=6V
F = 10 V
H = 15 V
J = 20 V
K = 25 V
M = 35 V
N = 50 V
This is expressed in
picofarads. The first
two digits are the
significant figures.
The third is the
number of zeros to
follow.
Blank = bulk,
plastic tray
/FA = waffle
pack
/PR =
100 pcs reel
/HR = half reel
/TR = full reel
Notes
(1)
Contact marketing for availability of Weibull D failure rate for 50 V ratings
(2)
T level requires surge current option “C”. Capacitors are recommended for “space applications”. Shipped in tape and reel / or waffle
packaging only
(3)
Individual reels may include capacitors of two date codes that will be separated by an empty pocket.
Reel labels will show both date codes. The date code on the top (DC1) is the inner tape layers or first capacitors reeled
DIMENSIONS
in inches [millimeters]
-
+
H
T
2
(max.)
Weld and dimple
projection identifies
anode (+) terminal
W
T
1 -
P
P
L
CASE CODE
A
B
C
D
E
F
G
H
L
0.100 ± 0.015
[2.54 ± 0.38]
0.150 ± 0.015
[3.81 ± 0.38]
0.200 ± 0.015
[5.08 ± 0.38]
0.150 ± 0.015
[3.81 ± 0.38]
0.200 ± 0.015
[5.08 ± 0.38]
0.220 ± 0.015
[5.59 ± 0.38]
0.265 ± 0.015
[6.73 ± 0.38]
0.285 ± 0.015
[7.24 ± 0.38]
W
0.050 ± 0.015
[1.27 ± 0.38]
0.050 ± 0.015
[1.27 ± 0.38]
0.050 ± 0.015
[1.27 ± 0.38]
0.100 ± 0.015
[2.54 ± 0.38]
0.100 ± 0.015
[2.54 ± 0.38]
0.135 ± 0.015
[3.43 ± 0.38]
0.110 ± 0.015
[2.79 ± 0.38]
0.150 ± 0.015
[3.81 ± 0.38]
H
0.050 ± 0.015
[1.27 ± 0.38]
0.050 ± 0.015
[1.27 ± 0.38]
0.050 ± 0.015
[1.27 ± 0.38]
0.050 ± 0.015
[1.27 ± 0.38]
0.050 ± 0.015
[1.27 ± 0.38]
0.070 ± 0.015
[1.78 ± 0.38]
0.110 ± 0.015
[2.79 ± 0.38]
0.110 ± 0.015
[2.79 ± 0.38]
P
0.030 ± 0.005
[0.76 ± 0.13]
0.030 ± 0.005
[0.76 ± 0.13]
0.030 ± 0.005
[0.76 ± 0.13]
0.030 ± 0.005
[0.76 ± 0.13]
0.030 ± 0.005
[0.76 ± 0.13]
0.030 ± 0.005
[0.76 ± 0.13]
0.050 ± 0.005
[1.27 ± 0.13]
0.050 ± 0.005
[1.27 ± 0.13]
T
1
0.005
[0.13]
0.005
[0.13]
0.005
[0.13]
0.005
[0.13]
0.005
[0.13]
0.005
[0.13]
0.005
[0.13]
0.005
[0.13]
T
2
(max.)
0.015
[0.38]
0.015
[0.38]
0.015
[0.38]
0.015
[0.38]
0.015
[0.38]
0.015
[0.38]
0.015
[0.38]
0.015
[0.38]
Note
• When solder coated terminations are required, add 0.015" [0.38 mm] to termination dimension tolerances
Revision: 23-Oct-2020
Document Number: 40009
1
For technical questions, contact:
tantalum@vishay.com
THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT
ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT
www.vishay.com/doc?91000
Mid-Autumn Festival Gift-TI-36X Pro Scientific Calculator
Thanks to EE for the gift during the Mid-Autumn Festival:Very powerful, with integrated solar charging!!...
电子微创意 Energy Infrastructure?
RedHat Linux installation diagram
My own summary, novice...
chenruichao123 Linux and Android
AXD debugging issues
[size=18px]In the Memory Start address text box, the user can enter the start address according to the memory address to be viewed or modified. The table below will list 64 consecutive addresses. Beca...
tulao Embedded System
Reset mode of TMS320C6678
There are four reset modes in total. The first three reset modes will trigger RESETSTAT, while local reset will not trigger RESETSTAT.(1) Power-on reset(2) Hardware reset(3) Software resetSee the manu...
灞波儿奔 DSP and ARM Processors
C51 Interrupt
In a C51 interrupt function, is it possible to change the value of a global variable? If so, does the variable have to be declared volatile?...
frankwz Embedded System
ucos is transplanted on MCF52233DEMO, and the routine code is all there, but why can't it run normally?
I am a newbie, and I have got the example program transplanted by ucos on MCF52233DEMO, but I can't run it myself...:Sad:Now single tasks can be executed, but multi-tasking cannot be executed. Only th...
silongGG Real-time operating system RTOS

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1284  2367  316  2446  56  26  48  7  50  2 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号