Z General-purpose Basic Switches are built into ZE, ZV,
and ZV2 Switches. They provided high durability and high
breaking capacity.
•
X Basic Switches with magnetic blowout are built into XE,
XV, and XV2 Switches. DC models have also been added
to the series.
•
Three mounting methods (side, base, and diagonal side)
and many types of actuator are available.
•
Terminals face the front when the cover is removed for
easy connection.
•
Switches with ground terminals have CE marking.
•
Approved by UL, CSA, and CCC (Chinese standard).
(Ask your OMRON representative for information on
approved models.)
Be sure to read
Safety Precautions
on page 8 to 9 and
Safety Precautions for All Limit Switches.
CSM_ZE_ZV_ZV2_XE_XV_XV2_DS_E_2_1
Model Number Structure
Model Number Legend
(Not all combinations are possible. Ask your OMRON representative for details.)
@@-@-2@
(1) (2) (3)
(4)
(3) Actuator
Q
Q22
Q21
QA2
QA277
N
N22
N21
NA2
NA277
: Plunger
: Roller plunger
: Crossroller plunger
: Roller arm lever
: One-way action roller arm lever
: Sealed plunger
: Sealed roller plunger (ZE, ZV, ZV2 only)
: Sealed crossroller plunger (ZE, ZV, ZV2 only)
: Sealed roller arm lever
: Sealed one-way action roller arm lever
(1) Built-in Switch
Z
X
: SPDT (AC)
: SPDT (DC)
(4) Conduit/Ground Terminal
*
None
G1
G
SG1
YG1
S
Y
: G 1/2/without ground terminal
: G 1/2/with ground terminal
: Pg13.5/with ground terminal
: 1/2-14NPSM/with ground terminal
: M20/with ground terminal
: 1/2-14NPSM/without ground terminal
: M20/without ground terminal
(2) Mounting Direction
E : Side mounting
V : Base mounting
V2 : Diagonal side mounting
* Consult with your OMRON representative concerning availability, pricing, and delivery of conduit sizes and ground terminal specifications other than those on standard
models.
1
ZE/ZV/ZV2/XE/XV/XV2
Ordering Information
Side mounting
Base mounting
Diagonal side mounting
Mounting
Actuator
AC
Plunger
DC
AC
Roller plunger
DC
General
purpose
AC
Crossroller plunger
DC
AC
Roller arm lever
DC
One-way action roller
arm lever
AC
DC
AC
Sealed plunger
DC
Sealed roller plunger
Sealed
(Booted)
Sealed crossroller
plunger
Sealed roller arm lever
DC
One-way action
sealed roller arm lever
AC
DC
AC
AC
AC
Model
ZE-Q-2
XE-Q-2
ZE-Q22-2
XE-Q22-2
ZE-Q21-2
XE-Q21-2
ZE-QA2-2
XE-QA2-2
ZE-QA277-2
XE-QA277-2
ZE-N-2
XE-N-2
ZE-N22-2
ZE-N21-2
ZE-NA2-2
XE-NA2-2
ZE-NA277-2
XE-NA277-2
Approved
standards
UL
●
CSA
●
Model
ZV-Q-2
XV-Q-2
Approved
standards
UL
●
CSA
●
Model
ZV2-Q-2
XV2-Q-2
Approved
standards
UL
●
CSA
●
●
●
ZV-Q22-2
XV-Q22-2
●
●
ZV2-Q22-2
XV2-Q22-2
●
●
●
●
ZV-Q21-2
XV-Q21-2
●
●
ZV2-Q21-2
---
●
●
●
●
ZV-QA2-2
XV-QA2-2
●
●
ZV2-QA2-2
XV2-QA2-2
ZV2-QA277-2
---
●
●
●
●
---
---
●
●
●
●
ZV-N-2
XV-N-2
●
●
ZV2-N-2
XV2-N-2
●
●
●
●
●
●
●
●
ZV-N22-2
ZV-N21-2
ZV-NA2-2
XV-NA2-2
●
●
●
●
●
●
ZV2-N22-2
ZV2-N21-2
ZV2-NA2-2
XV2-NA2-2
●
●
●
●
●
●
●
●
ZV-NA277-2
---
●
●
ZV2-NA277-2
XV2-NA277-2
●
●
Note: 1. The diagonal side mounting model feature improved sealing property, improved mounting strength through use of M5 screws, increased stability in seating with
large mounting width (31 x 75 mm) and permit coupling of a number of Switch units.
2. Ask your OMRON representative for information on models with ground terminals.
Specifications
Approved Standards
Agency
UL
CSA
CCC (CQC)
Standard
UL508
CSA C22.2 No.14
GB14048.5
File No.
E76675
LR45746
2003010303077623
Note: 1. Models XE, XV, and XV2 are not approved by UL, CSA, and CCC.
2. Ask your OMRON representative for information on approved models.
Ratings
Non-inductive load (A)
Model
Rated
voltage
125 VAC
250 VAC
480 VAC
125 VDC
250 VDC
8 VDC
14 VDC
30 VDC
125 VDC
250 VDC
Resistive load
NC
ZE-@
ZV-@
ZV2-@
15
15
10
0.5
0.25
10
10
10
10
3
3
3
3
3
1.5
NO
Lamp load
NC
3
2.5
1.5
0.5
0.25
1.5
1.5
1.5
1.5
0.75
NO
1.5
1.25
0.75
NC
15
15
6
0.05
0.03
10
10
10
7.5
2
10
10
10
6
1.5
5
5
5
2
2
Inductive load (A)
Inductive load
NO
Motor load
NC
5
3
1.5
0.05
0.03
2.5
2.5
2.5
2.5
1.5
Note: 1. The above figures are for standard currents.
2. Inductive loads have a power factor of 0.4 min.
(AC) and a time constant of 7 ms max. (DC).
3. Lamp load has an inrush current of 10 times
the steadystate current.
4. Motor load has an inrush current of 6 times the
steady-state current.
NO
2.5
1.5
0.75
Inrush
current
NC
NO
30 A max.
15 A max.
XE-@
XV-@
XV2-@
2
ZE/ZV/ZV2/XE/XV/XV2
Approved Standard Ratings
UL/CSA
Model
Rated voltage
125 VAC
250 VAC
480 VAC
125 VDC
250 VDC
Current
15 A
15 A
15 A
0.5 A
0.25 A
Horsepower
1/8HP
1/4HP
---
Operating speed
Durability
*2
Characteristics
Degree of protection
Mechanical
IP65*1
Z@: 10,000,000 operations min.
X@: 1,000,000 operations min.
Z@: 500,000 operations min., for 15 A,
250 VAC resistive load
X@: 100,000 operations min., for 10 A,
125 VDC resistive load
Plunger type: 0.01 mm/s to 0.5 m/s
Lever type: 0.02 mm/s to 0.5 m/s
120 operations/min
20 operations/min
50/60 Hz
100 MΩ min. (at 500 VDC)
15 mΩ max. (initial value)
50°C max.
1,000 VAC, 50/60 Hz for 1 min
Z@: 2,000 VAC, 50/60 Hz for 1 min
X@: 1,500 VAC, 50/60 Hz for 1 min
Z@: 2,000 VAC, 50/60 Hz for 1 min
X@: 1,500 VAC, 50/60 Hz for 1 min
10 to 55 Hz, 1.5-mm double amplitude*3
1,000m/s
2
min.
100 m/s
2
min.*4
50 m/s
2
min.*5
−10°C
to +80°C (with no icing)
General-purpose type: 35% to 85%RH
Sealed type: 35% to 95%RH
Approx. 260 to 280 g
ZE
Electrical
CCC (GB14048.5)
Applicable category and ratings
AC-12 10 A/250 VAC
Mechanical
Electrical
Rated frequency
Insulation resistance
Contact resistance
Terminal temperature rise
Between terminals
of the same polarity
Between current-
carrying metal
Dielectric
part and ground
strength
Between each
terminal and
non-current-car-
rying metal part
Vibration
Malfunction
resistance
Destruction
Shock
resistance
Malfunction
*3
Operating
frequency
Ambient operating temperature
Ambient operating humidity
Weight
Note: The above figures are initial values.
*1. IP65 for
@-N
models and IP60 for
@-Q
models.
*2. The values are calculated at an operating temperature of +5°C to +35°C, and an
operating humidity of 40% to 70%RH. Contact your OMRON sales
representative for more detailed information on other operating environments.
*3. At the operation limit positions.
*4. Only for plunger, sealed plunger, roller arm lever, and sealed roller arm
lever.
*5. Only for crossroller plunger, sealed crossroller plunger, roller plunger, and
sealed roller plunger.
Engineering Data
Electrical Durability
ZE (cosφ = 1)
Durability (x 10
4
operations)
Operating frequency:
20 operations/min
OT: Full stroke
XE (L/R = 0)
Durability (x 10
4
operations)
Operating frequency:
20 operations/min
OT: Full stroke
200
125 VAC
100
70
50
250 VAC
1,000
125 VAC
500
250 VAC
100
480 VAC
50
0
2
4
6
8
10
12
14 16
Switching current (A)
0
1
2
3
5
10
Switching current (A)
ZE (cosφ = 0.4)
Durability (x 10
4
operations)
Operating frequency:
20 operations/min
OT: Full stroke
1,000
500
250 VAC
480 VAC
100
50
0
2
4
6
8
10
12
14
16
XE (L/R = 7 ms)
Durability (x 10
4
operations)
Operating frequency:
20 operations/min
OT: Full stroke
100
70
50
30
20
250 VAC
125 VAC
125 VAC
0
1
2
3
5
Switching current (A)
10
Switching current (A)
3
ZE/ZV/ZV2/XE/XV/XV2
Structure and Nomenclature
Structure
ZE-NA2-2
COM
NC
NO
Contact Form
Pin plunger
Tightening band
Case
Rubber cap (CR)
Note: With the XE-@, XV-@, and XV2-@@, be sure to connect COM to the
+ terminal.
Separator
Built-in switch
Terminal
Conduit
opening
Cover
Seal rubber (NBR)
Note: The conduit thread indication has been changed from "PF1/2" to "G1/2"
accompanying the JIS B 0202 revision. This changes applies only to the
indication; thread sizes and pitches have not been affected.
Dimensions and Operating Characteristics
Side Mounting Models
Plunger
ZE-Q-2
XE-Q-2
Two, M4
(length: 45)
(Unit: mm)
12R *
JIS B0202 G1/2
Effective thread:
4 threads min.
17
PT
Roller Plunger
ZE-Q22-2
XE-Q22-2
Two, M4
(length: 45)
12.7 dia.
×
4.8 *
JIS B0202 G1/2
Effective thread:
4 threads min.
17
19
25.5
2.1
±
0.1
86
* Stainless steel roller
25.4
±
0.12
24
PT
OP
19
25.5
2.1
±
0.1
86
* Stainless steel plunger
25.4
±
0.12
24
OP
23
23
25.4
±
0.3
25.4
±
0.3
Crossroller Plunger
ZE-Q21-2
XE-Q21-2
Two, M4
(length: 45)
12.7 dia.
×
4.8 *
JIS B0202 G1/2
Effective thread:
4 threads min.
17
PT
Roller Arm Lever
ZE-QA2-2
XE-QA2-2
Two, M4
(length: 45)
19.1 dia.
×
7.9 *1
(23.1)
JIS B0202 G1/2
Effective thread:
4 threads min.
PT
17
39.7
*2
OP
19
25.5
2.1
±
0.1
86
25.4
±
0.12
24
44
±
0.8
19.3
19
25.5
2.1
±
0.1
23
23
25.4
±
0.3
* Stainless steel roller
25.4
±
0.3
86
25.4
±
0.12
24
*1. Stainless sintered roller
*2. Adjustable between 0° and 225°
Note: 1. Unless otherwise specified, a tolerance of
±0.4
mm applies to all dimensions.
2. The diagrams shown the Switches with two, M4 screws (length: 45) attached. (The screws are provided.)
Operating
characteristics
Operating force
Release force
Pretravel
Over Travel
Movement Differential
Operating Position
Model
OF
RF min.
PT max.
OT min.
MD max.
OP
ZE-Q-2
2.45 to 3.43 N
1.12 N
0.4 mm
5.5 mm
0.05 mm
XE-Q-2
5.00 N max.
1.12 N
0.9 mm
5.5 mm
0.47 mm
ZE-Q22-2
2.45 to 3.43 N
1.12 N
0.5 mm
3.6 mm
0.05 mm
XE-Q22-2
5.00 N max.
1.12 N
0.9 mm
3.6 mm
0.47 mm
ZE-Q21-2
2.45 to 3.43 N
1.12 N
0.5 mm
3.6 mm
0.05 mm
XE-Q21-2
5.00 N max.
1.12 N
0.9 mm
3.6 mm
0.47 mm
ZE-QA2-2
5.59 N max.
1.67 N
4 mm
6 mm
0.4 mm
---
XE-QA2-2
6.47 N max.
1.67 N
6 mm
5.5 mm
0.72 mm
38.2±0.8 mm
49.7±1 mm
49.7±1 mm
4
ZE/ZV/ZV2/XE/XV/XV2
One-way Action Roller Arm Lever
ZE-QA277-2
18.7 dia.
×
9 *1
XE-QA277-2
(40)
17.4R
JIS B0202 G1/2
Effective thread:
4 threads min.
17
Operate in this
direction only
Sealed Plunger
ZE-N-2
XE-N-2
12R *
JIS B0202 G1/2
Effective thread:
4 threads min.
39.7
*2
PT
PT
44
±
0.8
19.3
19
25.5
2.1
±
0.1
23
Two, M4
(length: 45)
Two, M4
(length: 45)
17
19
25.5
2.1
±
0.1
86
* Stainless steel plunger
OP
23
25.4
±
0.3
25.4
±
0.12
86
*1. Stainless sintered alloy roller
*2. Adjustable between 0° and 225°
24
25.4
±
0.3
25.4
±
0.12
24
Sealed Roller Plunger
ZE-N22-2
Two, M4
(length: 45)
12.7 dia.
×
4.8 *
JIS B0202 G1/2
Effective thread:
4 threads min.
17
19
25.5
2.1
±
0.1
86
* Stainless steel roller
25.4
±
0.12
24
Sealed Crossroller Plunger
ZE-N21-2
PT
12.7 dia.
×
4.8 *
JIS B0202 G1/2
Effective thread:
4 threads min.
17
PT
OP
Two, M4
(length: 45)
OP
19
25.5
2.1
±
0.1
86
25.4
±
0.12
24
23
23
25.4
±
0.3
25.4
±
0.3
* Stainless steel roller
Sealed Roller Arm Lever
ZE-NA2-2
XE-NA2-2
19.1 dia.
×
7.9 *1
39.7
(23.1)
*2
One-way Action Sealed Roller Arm Lever
18.7 dia.
×
9 *1
ZE-NA277-2
XE-NA277-2
(40)
17.4R
JIS B0202 G1/2
Effective thread:
4 threads min.
Operate in this
direction only
39.7
*2
Two, M4
(length: 45)
JIS B0202 G1/2
Effective thread:
4 threads min.
17
PT
53.4
±
0.8
19.3
19
25.5
2.1
±
0.1
86
25.4
±
0.12
24
Two, M4
(length: 45)
PT
53.4
±
0.8
19.3
19
25.5
2.1
±
0.1
86
25.4
±
0.12
24
17
23
23
25.4
±
0.3
25.4
±
0.3
*1. Stainless sintered alloy roller
*2. Adjustable between 0° and 225°
*1. Stainless steel roller
*2. Adjustable between 0° and 225°
Note: 1. Unless otherwise specified, a tolerance of
±0.4
mm applies to all dimensions.
2. The diagrams shown the Switches with two, M4 screws (length: 45) attached. (The screws are provided.)
Mobile phone design trends make it increasingly difficult to meet these requirements by adding antennas, but still find ways to support new RF standards and meet multi-band coexistence expansion requi...
I used SJF to burn the compiled marquee program [img]http://docs.google.com/File?id=dd24dnkn_26hc2g37fs_b[/img] After burning, setting it to boot from NAND FLASH had no effect, and there was still no ...
The battle over smartphone operating systems is endless and is only getting more intense.
For terminals, the importance of operating systems is self-evident. This melee in the operating system market ...
[size=4]In the past, eight out of ten people who worked on drones were from the fields of aviation, pneumatics, and mechanics, and they were more concerned about how to make the aircraft fly stably, f...
I have 20+ PIC16F1825 dual in-line chips. Anyone want them? qq421403872 I have 8-bit Fujitsu emulators I have 50+ AT89c52s I have 2 Nuvoton development boards I have...
1. Overview
Will passive devices
produce nonlinear intermodulation distortion? The answer is yes! Although there is no systematic theoretical analysis, it has been found in engineerin...[Details]
Do you often have to add brake fluid to your car's brakes? The fact that you need to pump out the brake fluid to make sure there is no gas in the brake fluid line may not be done by the car owner h...[Details]
For a long time, due to the limitation of hardware conditions, the display devices of traditional small handheld devices such as PDA are usually monochrome LCD, and the user interface is very simpl...[Details]
Abstract: In order to realize wireless automatic alarm and monitoring of major safety places, based on the basic principle of pyroelectric infrared sensing, a detector for receiving infrared radia...[Details]
1 Development of LED Film and Television Lighting
1.1 The significance of developing film and television lighting
Lighting power consumption accounts for a large proportion of the total p...[Details]
Mobile phones, MP3s, tablet computers, laptops, digital cameras, handheld game consoles, navigation devices, etc., all these mobile devices are powered by mobile batteries, and the battery life is ...[Details]
Features
POE technology can ensure the safety of existing structured cabling while ensuring the normal operation of the existing network and minimizing costs. The IEEE 802.3af standard is ...[Details]
1 Introduction
Fieldbus is a serial, digital, multi-point communication data bus between field equipment/instruments installed in the production process area and automatic control devices/syst...[Details]
1. Introduction
Stepper motor is a basic component that converts electrical energy into kinetic energy. It has been widely used in a variety of electromechanical equipment, such as various machine...[Details]
Today, fleet management innovation has made great progress. Whether trucks, buses, taxis or other means of transportation, wireless satellite positioning systems are used to enable dispatchers to u...[Details]
"Multimeter" is the abbreviation of multimeter, which is an indispensable tool in our electronic production. The advantages of multimeter are that it has many uses, a wide range, an...[Details]
1 Theoretical Analysis
Ultrasonic waves
When propagating in a suspension, the ultrasonic waves that encounter the suspended particles are scattered and attenuated at the interface, an...[Details]
Background
The proliferation of ultra-low-power wireless sensor nodes for measurement and control purposes, combined with new energy harvesting techniques, has made it possible to create ful...[Details]
Multimedia applications such as mobile TV, mobile gaming, and audio playback present a huge challenge to power management design in mobile phones. Mobile phone designers need to keep the phone smal...[Details]
According to a survey by the International Energy Agency, Asia and Australia used 1.65 trillion liters of oil for energy in 2004. The survey also showed that since 1990, the demand for oil has been...[Details]