EEWORLDEEWORLDEEWORLD

Part Number

Search

ZWS300BAF24/A

Description
AC/DC converter 24v 12.5A 300w
Categorysemiconductor    Power management   
File Size477KB,2 Pages
ManufacturerTDK Corporation
Websitehttp://www.tdk.com
Environmental Compliance  
Download Datasheet Parametric View All

ZWS300BAF24/A Overview

AC/DC converter 24v 12.5A 300w

ZWS300BAF24/A Parametric

Parameter NameAttribute value
Datasheets
ZWS300BAF Series
ZWS-BAF Series Instr Manual
ZWS300BAF/A Spec
ZWS300BAF/A Drawing
Standard Package1
CategoryPower Supplies - External/Internal (Off-Board)
FamilyAC DC Converters
TypeEnclosed
Number of Outputs1
Voltage - Inpu85 ~ 265 VAC
Voltage - Output 124V
Voltage - Output 2-
Voltage - Output 3-
Voltage - Output 4-
Current - Output (Max)12.5A
Power (Watts)300W
ApplicationsITE (Commercial)
Voltage - Isolati3kV (3000V)
Efficiency88%
Operating Temperature-10°C ~ 60°C
FeaturesAdjustable Output, PFC, Universal Inpu
Mounting TypeChassis Mou
Size / Dimensi7.09" L x 3.31" W x 1.54" H (180.0mm x 84.0mm x 39.0mm)
Minimum Load Required-
ApprovalsCE
Power (Watts) - Max300W
Associated Produc455-1186-ND - CONN HOUSING VH 5POS 3.96MM WHT455-1168-ND - CONN HOUSING VH 8POS 3.96MM WHT
ZWS300BAF Series
300W Single Output, Convection Cooled Power Supplies
Features
Universal Input (85 - 265VAC)
Power Factor Corrected
Convection cooling (300W) or Forced Air (336-338W)
Five year warranty
Less than 0.5mA earth leakage current
Key Market Segments & Applications
Specifications
Model
Input Voltage
Input Current
Inrush Current
(1)(2)
Power Factor
Leakage Current
Off Load Power Draw
Temperature Coefficient
Overcurrent Protection
(3)
Overvoltage Protection
Hold Up Time (Typ)
(1)
Efficiency
(1)
Remote On/Off
Operating Temperature
12V & 15V Models
Operating Temperature
24V, 36V & 48V Models
Storage Temperature
Humidity (non condensing)
Cooling
Withstand Voltage
V
A
A
-
mA
W
%/°C
-
V
ms
%
-
°C
°C
ZWS300BAF
85-265VAC (47-63Hz), 120-370VDC
(5)
3.7 / 1.9 (Convection cooled rating)
15 / 30
0.97 at 100VAC, 0.93 at 200VAC, Meets EN61000-3-2
0.5mA Max. Typically 0.2mA (100VAC), 0.4mA (230VAC)
Typically 0.1W at 100VAC, 0.5W at 200VAC, 0.8W at 265VAC when unit is in inhibit
<0.02%/°C
>116% of convection cooled rated output current (>105% for 12V model)
12V: 13.8-16.2V, 15V: 17.3-20.3V, 24V: 28.8-33.6V, 36V: 41.4-48.6V, 48V: 55.2-64.8V
18ms at 100VAC input (Convection cooled rating)
12 & 15V models: 86 / 89%, 24V, 36V & 48V models: 88 / 91% (Convection cooled rating)
Optional, see instruction manual
Convection: -10°C to +70°C, derate linearly to 40% load from 40°C to 70°C
1.4m/s Airflow: -10°C to +70°C, derate linearly to 60% load from 50°C to 70°C
Convection: -10°C to +70°C, derate linearly to 40% load from 45°C to 70°C
0.7m/s Airflow: -10°C to +70°C, derate linearly to 60% load from 50°C to 70°C
1.4m/s Airflow: -10°C to +70°C, derate linearly to 70% load from 60°C to 70°C
-30 to +75°C
Operating: 30 - 90%RH, Storage: 10 - 90%RH
Convection or forced air
Input to Ground 2kVAC (20mA), Input to Output 3kVAC (20mA), Output to Ground 500VAC
(20mA) for 1 min.
>100M at 25°C & 70%RH, Output to Ground 500VDC
10 - 55Hz (1 minute sweep), 19.6m/s
2
constant X, Y, Z 1 hour each
< 196.1 m/s
2
UL60950-1, CSA60950-1, EN60950-1, EN50178 OV II, CE Mark
EN55011/EN55022-B, FCC Class B, VCCI-B
EN61000-4-2 (lvl2, 3), -3 (lvl 3), -4 (lvl 3), -5 (lvl 3, 4), -6 (lvl 3), -8 (lvl 4), -11; EN61000-6-2
540g (open frame)
3.31 x 1.65 x 7.09” (84 x 42 x 180) open frame
Five Years
°C
%RH
-
-
Isolation Resistance
-
Vibration (non operating)
-
Shock
-
Safety Agency Certifications
-
(4)
Conducted & Radiated EMI
-
Immunity
-
Weight (Typ)
g
Size (WxHxD)
in (mm)
Warranty
yrs
Notes:
(1) 100 / 200VAC Input
(2) 25°C ambient (cold start)
(3) Avoid prolonged operartion in overload
(4) Forced air rating: Class A radiated
(5) Safety certified for AC input only
1-800-526-2324 • www.us.tdk-lambda.com/lp/
113
Disclaimer: us.tdk-lambda.com/lp/legal.htm
【Link Node Trial】Failed to connect the phone to the board
[size=4]I tried to burn the program, but the phone couldn't find the board. . . . :faint:[/size] [size=4][/size] [size=4] [/size] [size=4]Has anyone tested this? ? [/size]...
数码小叶 RF/Wirelessly
【mpy】STM32 supports using HSI as the main clock
MicroPython has set up an HSI clock option, allowing the use of HSI as the master clock. The advantage is that it is more adaptable, but the disadvantage is that USB may not be used. [url]https://gith...
dcexpert MicroPython Open Source section
A small problem based on Windows programming
#include LRESULT CALLBACK WndProc(HWND,UINT,WPARAM,LPARAM); //---------The following initialization window class------------ int WINAPI WinMain(HINSTANCE hInstance,HINSTANCE hPrevInst, LPSTR lpszCmdLi...
zuoqi Embedded System
OK...........................
.............................. [[i] This post was last edited by pr8800 on 2009-3-24 17:04 [/i]]...
pr8800 Embedded System
PROTEL99 Design Skills
[align=left]1. Common errors in schematics: [/font] [font=Tahoma](1) ERC[/font][font=Songti] reports that the pin is not connected to the signal: [/font] [font=Tahoma]a. [/font][font=Songti]I/O[/font]...
jdbzhl PCB Design
How to access C51's external RAM?
I have expanded a 6264 using 74LS373 and 74LS138. The address of 6264 is 0x6000. How can I access 6264 using #define XPORT XBYTE[0x6000]? Can I use unsinged char xdata temp? I am a beginner in C51. Pl...
dyqq46 Embedded System

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 498  165  124  375  888  11  4  3  8  18 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号