Z General-purpose Basic Switches are built into ZE, ZV,
and ZV2 Switches. They provided high durability and high
breaking capacity.
•
X Basic Switches with magnetic blowout are built into XE,
XV, and XV2 Switches. DC models have also been added
to the series.
•
Three mounting methods (side, base, and diagonal side)
and many types of actuator are available.
•
Terminals face the front when the cover is removed for
easy connection.
•
Switches with ground terminals have CE marking.
•
Approved by UL, CSA, and CCC (Chinese standard).
(Ask your OMRON representative for information on
approved models.)
Be sure to read
Safety Precautions
on page 8 to 9 and
Safety Precautions for All Limit Switches.
CSM_ZE_ZV_ZV2_XE_XV_XV2_DS_E_2_1
Model Number Structure
Model Number Legend
(Not all combinations are possible. Ask your OMRON representative for details.)
@@-@-2@
(1) (2) (3)
(4)
(3) Actuator
Q
Q22
Q21
QA2
QA277
N
N22
N21
NA2
NA277
: Plunger
: Roller plunger
: Crossroller plunger
: Roller arm lever
: One-way action roller arm lever
: Sealed plunger
: Sealed roller plunger (ZE, ZV, ZV2 only)
: Sealed crossroller plunger (ZE, ZV, ZV2 only)
: Sealed roller arm lever
: Sealed one-way action roller arm lever
(1) Built-in Switch
Z
X
: SPDT (AC)
: SPDT (DC)
(4) Conduit/Ground Terminal
*
None
G1
G
SG1
YG1
S
Y
: G 1/2/without ground terminal
: G 1/2/with ground terminal
: Pg13.5/with ground terminal
: 1/2-14NPSM/with ground terminal
: M20/with ground terminal
: 1/2-14NPSM/without ground terminal
: M20/without ground terminal
(2) Mounting Direction
E : Side mounting
V : Base mounting
V2 : Diagonal side mounting
* Consult with your OMRON representative concerning availability, pricing, and delivery of conduit sizes and ground terminal specifications other than those on standard
models.
1
ZE/ZV/ZV2/XE/XV/XV2
Ordering Information
Side mounting
Base mounting
Diagonal side mounting
Mounting
Actuator
AC
Plunger
DC
AC
Roller plunger
DC
General
purpose
AC
Crossroller plunger
DC
AC
Roller arm lever
DC
One-way action roller
arm lever
AC
DC
AC
Sealed plunger
DC
Sealed roller plunger
Sealed
(Booted)
Sealed crossroller
plunger
Sealed roller arm lever
DC
One-way action
sealed roller arm lever
AC
DC
AC
AC
AC
Model
ZE-Q-2
XE-Q-2
ZE-Q22-2
XE-Q22-2
ZE-Q21-2
XE-Q21-2
ZE-QA2-2
XE-QA2-2
ZE-QA277-2
XE-QA277-2
ZE-N-2
XE-N-2
ZE-N22-2
ZE-N21-2
ZE-NA2-2
XE-NA2-2
ZE-NA277-2
XE-NA277-2
Approved
standards
UL
●
CSA
●
Model
ZV-Q-2
XV-Q-2
Approved
standards
UL
●
CSA
●
Model
ZV2-Q-2
XV2-Q-2
Approved
standards
UL
●
CSA
●
●
●
ZV-Q22-2
XV-Q22-2
●
●
ZV2-Q22-2
XV2-Q22-2
●
●
●
●
ZV-Q21-2
XV-Q21-2
●
●
ZV2-Q21-2
---
●
●
●
●
ZV-QA2-2
XV-QA2-2
●
●
ZV2-QA2-2
XV2-QA2-2
ZV2-QA277-2
---
●
●
●
●
---
---
●
●
●
●
ZV-N-2
XV-N-2
●
●
ZV2-N-2
XV2-N-2
●
●
●
●
●
●
●
●
ZV-N22-2
ZV-N21-2
ZV-NA2-2
XV-NA2-2
●
●
●
●
●
●
ZV2-N22-2
ZV2-N21-2
ZV2-NA2-2
XV2-NA2-2
●
●
●
●
●
●
●
●
ZV-NA277-2
---
●
●
ZV2-NA277-2
XV2-NA277-2
●
●
Note: 1. The diagonal side mounting model feature improved sealing property, improved mounting strength through use of M5 screws, increased stability in seating with
large mounting width (31 x 75 mm) and permit coupling of a number of Switch units.
2. Ask your OMRON representative for information on models with ground terminals.
Specifications
Approved Standards
Agency
UL
CSA
CCC (CQC)
Standard
UL508
CSA C22.2 No.14
GB14048.5
File No.
E76675
LR45746
2003010303077623
Note: 1. Models XE, XV, and XV2 are not approved by UL, CSA, and CCC.
2. Ask your OMRON representative for information on approved models.
Ratings
Non-inductive load (A)
Model
Rated
voltage
125 VAC
250 VAC
480 VAC
125 VDC
250 VDC
8 VDC
14 VDC
30 VDC
125 VDC
250 VDC
Resistive load
NC
ZE-@
ZV-@
ZV2-@
15
15
10
0.5
0.25
10
10
10
10
3
3
3
3
3
1.5
NO
Lamp load
NC
3
2.5
1.5
0.5
0.25
1.5
1.5
1.5
1.5
0.75
NO
1.5
1.25
0.75
NC
15
15
6
0.05
0.03
10
10
10
7.5
2
10
10
10
6
1.5
5
5
5
2
2
Inductive load (A)
Inductive load
NO
Motor load
NC
5
3
1.5
0.05
0.03
2.5
2.5
2.5
2.5
1.5
Note: 1. The above figures are for standard currents.
2. Inductive loads have a power factor of 0.4 min.
(AC) and a time constant of 7 ms max. (DC).
3. Lamp load has an inrush current of 10 times
the steadystate current.
4. Motor load has an inrush current of 6 times the
steady-state current.
NO
2.5
1.5
0.75
Inrush
current
NC
NO
30 A max.
15 A max.
XE-@
XV-@
XV2-@
2
ZE/ZV/ZV2/XE/XV/XV2
Approved Standard Ratings
UL/CSA
Model
Rated voltage
125 VAC
250 VAC
480 VAC
125 VDC
250 VDC
Current
15 A
15 A
15 A
0.5 A
0.25 A
Horsepower
1/8HP
1/4HP
---
Operating speed
Durability
*2
Characteristics
Degree of protection
Mechanical
IP65*1
Z@: 10,000,000 operations min.
X@: 1,000,000 operations min.
Z@: 500,000 operations min., for 15 A,
250 VAC resistive load
X@: 100,000 operations min., for 10 A,
125 VDC resistive load
Plunger type: 0.01 mm/s to 0.5 m/s
Lever type: 0.02 mm/s to 0.5 m/s
120 operations/min
20 operations/min
50/60 Hz
100 MΩ min. (at 500 VDC)
15 mΩ max. (initial value)
50°C max.
1,000 VAC, 50/60 Hz for 1 min
Z@: 2,000 VAC, 50/60 Hz for 1 min
X@: 1,500 VAC, 50/60 Hz for 1 min
Z@: 2,000 VAC, 50/60 Hz for 1 min
X@: 1,500 VAC, 50/60 Hz for 1 min
10 to 55 Hz, 1.5-mm double amplitude*3
1,000m/s
2
min.
100 m/s
2
min.*4
50 m/s
2
min.*5
−10°C
to +80°C (with no icing)
General-purpose type: 35% to 85%RH
Sealed type: 35% to 95%RH
Approx. 260 to 280 g
ZE
Electrical
CCC (GB14048.5)
Applicable category and ratings
AC-12 10 A/250 VAC
Mechanical
Electrical
Rated frequency
Insulation resistance
Contact resistance
Terminal temperature rise
Between terminals
of the same polarity
Between current-
carrying metal
Dielectric
part and ground
strength
Between each
terminal and
non-current-car-
rying metal part
Vibration
Malfunction
resistance
Destruction
Shock
resistance
Malfunction
*3
Operating
frequency
Ambient operating temperature
Ambient operating humidity
Weight
Note: The above figures are initial values.
*1. IP65 for
@-N
models and IP60 for
@-Q
models.
*2. The values are calculated at an operating temperature of +5°C to +35°C, and an
operating humidity of 40% to 70%RH. Contact your OMRON sales
representative for more detailed information on other operating environments.
*3. At the operation limit positions.
*4. Only for plunger, sealed plunger, roller arm lever, and sealed roller arm
lever.
*5. Only for crossroller plunger, sealed crossroller plunger, roller plunger, and
sealed roller plunger.
Engineering Data
Electrical Durability
ZE (cosφ = 1)
Durability (x 10
4
operations)
Operating frequency:
20 operations/min
OT: Full stroke
XE (L/R = 0)
Durability (x 10
4
operations)
Operating frequency:
20 operations/min
OT: Full stroke
200
125 VAC
100
70
50
250 VAC
1,000
125 VAC
500
250 VAC
100
480 VAC
50
0
2
4
6
8
10
12
14 16
Switching current (A)
0
1
2
3
5
10
Switching current (A)
ZE (cosφ = 0.4)
Durability (x 10
4
operations)
Operating frequency:
20 operations/min
OT: Full stroke
1,000
500
250 VAC
480 VAC
100
50
0
2
4
6
8
10
12
14
16
XE (L/R = 7 ms)
Durability (x 10
4
operations)
Operating frequency:
20 operations/min
OT: Full stroke
100
70
50
30
20
250 VAC
125 VAC
125 VAC
0
1
2
3
5
Switching current (A)
10
Switching current (A)
3
ZE/ZV/ZV2/XE/XV/XV2
Structure and Nomenclature
Structure
ZE-NA2-2
COM
NC
NO
Contact Form
Pin plunger
Tightening band
Case
Rubber cap (CR)
Note: With the XE-@, XV-@, and XV2-@@, be sure to connect COM to the
+ terminal.
Separator
Built-in switch
Terminal
Conduit
opening
Cover
Seal rubber (NBR)
Note: The conduit thread indication has been changed from "PF1/2" to "G1/2"
accompanying the JIS B 0202 revision. This changes applies only to the
indication; thread sizes and pitches have not been affected.
Dimensions and Operating Characteristics
Side Mounting Models
Plunger
ZE-Q-2
XE-Q-2
Two, M4
(length: 45)
(Unit: mm)
12R *
JIS B0202 G1/2
Effective thread:
4 threads min.
17
PT
Roller Plunger
ZE-Q22-2
XE-Q22-2
Two, M4
(length: 45)
12.7 dia.
×
4.8 *
JIS B0202 G1/2
Effective thread:
4 threads min.
17
19
25.5
2.1
±
0.1
86
* Stainless steel roller
25.4
±
0.12
24
PT
OP
19
25.5
2.1
±
0.1
86
* Stainless steel plunger
25.4
±
0.12
24
OP
23
23
25.4
±
0.3
25.4
±
0.3
Crossroller Plunger
ZE-Q21-2
XE-Q21-2
Two, M4
(length: 45)
12.7 dia.
×
4.8 *
JIS B0202 G1/2
Effective thread:
4 threads min.
17
PT
Roller Arm Lever
ZE-QA2-2
XE-QA2-2
Two, M4
(length: 45)
19.1 dia.
×
7.9 *1
(23.1)
JIS B0202 G1/2
Effective thread:
4 threads min.
PT
17
39.7
*2
OP
19
25.5
2.1
±
0.1
86
25.4
±
0.12
24
44
±
0.8
19.3
19
25.5
2.1
±
0.1
23
23
25.4
±
0.3
* Stainless steel roller
25.4
±
0.3
86
25.4
±
0.12
24
*1. Stainless sintered roller
*2. Adjustable between 0° and 225°
Note: 1. Unless otherwise specified, a tolerance of
±0.4
mm applies to all dimensions.
2. The diagrams shown the Switches with two, M4 screws (length: 45) attached. (The screws are provided.)
Operating
characteristics
Operating force
Release force
Pretravel
Over Travel
Movement Differential
Operating Position
Model
OF
RF min.
PT max.
OT min.
MD max.
OP
ZE-Q-2
2.45 to 3.43 N
1.12 N
0.4 mm
5.5 mm
0.05 mm
XE-Q-2
5.00 N max.
1.12 N
0.9 mm
5.5 mm
0.47 mm
ZE-Q22-2
2.45 to 3.43 N
1.12 N
0.5 mm
3.6 mm
0.05 mm
XE-Q22-2
5.00 N max.
1.12 N
0.9 mm
3.6 mm
0.47 mm
ZE-Q21-2
2.45 to 3.43 N
1.12 N
0.5 mm
3.6 mm
0.05 mm
XE-Q21-2
5.00 N max.
1.12 N
0.9 mm
3.6 mm
0.47 mm
ZE-QA2-2
5.59 N max.
1.67 N
4 mm
6 mm
0.4 mm
---
XE-QA2-2
6.47 N max.
1.67 N
6 mm
5.5 mm
0.72 mm
38.2±0.8 mm
49.7±1 mm
49.7±1 mm
4
ZE/ZV/ZV2/XE/XV/XV2
One-way Action Roller Arm Lever
ZE-QA277-2
18.7 dia.
×
9 *1
XE-QA277-2
(40)
17.4R
JIS B0202 G1/2
Effective thread:
4 threads min.
17
Operate in this
direction only
Sealed Plunger
ZE-N-2
XE-N-2
12R *
JIS B0202 G1/2
Effective thread:
4 threads min.
39.7
*2
PT
PT
44
±
0.8
19.3
19
25.5
2.1
±
0.1
23
Two, M4
(length: 45)
Two, M4
(length: 45)
17
19
25.5
2.1
±
0.1
86
* Stainless steel plunger
OP
23
25.4
±
0.3
25.4
±
0.12
86
*1. Stainless sintered alloy roller
*2. Adjustable between 0° and 225°
24
25.4
±
0.3
25.4
±
0.12
24
Sealed Roller Plunger
ZE-N22-2
Two, M4
(length: 45)
12.7 dia.
×
4.8 *
JIS B0202 G1/2
Effective thread:
4 threads min.
17
19
25.5
2.1
±
0.1
86
* Stainless steel roller
25.4
±
0.12
24
Sealed Crossroller Plunger
ZE-N21-2
PT
12.7 dia.
×
4.8 *
JIS B0202 G1/2
Effective thread:
4 threads min.
17
PT
OP
Two, M4
(length: 45)
OP
19
25.5
2.1
±
0.1
86
25.4
±
0.12
24
23
23
25.4
±
0.3
25.4
±
0.3
* Stainless steel roller
Sealed Roller Arm Lever
ZE-NA2-2
XE-NA2-2
19.1 dia.
×
7.9 *1
39.7
(23.1)
*2
One-way Action Sealed Roller Arm Lever
18.7 dia.
×
9 *1
ZE-NA277-2
XE-NA277-2
(40)
17.4R
JIS B0202 G1/2
Effective thread:
4 threads min.
Operate in this
direction only
39.7
*2
Two, M4
(length: 45)
JIS B0202 G1/2
Effective thread:
4 threads min.
17
PT
53.4
±
0.8
19.3
19
25.5
2.1
±
0.1
86
25.4
±
0.12
24
Two, M4
(length: 45)
PT
53.4
±
0.8
19.3
19
25.5
2.1
±
0.1
86
25.4
±
0.12
24
17
23
23
25.4
±
0.3
25.4
±
0.3
*1. Stainless sintered alloy roller
*2. Adjustable between 0° and 225°
*1. Stainless steel roller
*2. Adjustable between 0° and 225°
Note: 1. Unless otherwise specified, a tolerance of
±0.4
mm applies to all dimensions.
2. The diagrams shown the Switches with two, M4 screws (length: 45) attached. (The screws are provided.)
The progress is a bit slow, I can't catch up with everyone, so I'll release a design plan first. [b]1. Design goals[/b] It includes two parts: functions that must be completed and functions that are o...
Tingfengqieyin 16:48:08 May I ask, during CCS simulation, will the contents of the address where the interrupt vector table is located be modified when the program is running? Now when the program is ...
I am new to AVR series microcontrollers and have a lot of questions. I am eager to know how to burn the program into ATMEGA8 (what software, hardware, etc. are needed). Thank you very much! ! [[i] Thi...
How to use timer to realize interrupt? What are the specific operation steps? What should be paid attention to? The following is an example of using timer interrupt by an engineer: Now it is required ...
[i=s]This post was last edited by my student number on 2016-4-23 12:55[/i] [b][size=24px]2. Run the first script[/size][/b] From this tutorial, we will start running Python scripts on the pyboard. Aft...
The same-direction amplifier is made of TL062 and powered by a single 12V power supply. When 0V is input at the input, the output is directly more than 11V. I don't know where the problem is. I hope f...
Hardware designers have begun to adopt FPGA technology in high-performance DSP designs because it can provide 10-100 times faster computing than PC-based or microcontroller-based solutions. Previou...[Details]
1 Introduction
As an emerging microfabrication technology, micro-electromechanical system (MEMS) technology has begun to be applied in various fields. It can integrate functions such as inform...[Details]
The data collector of the automatic weather station is generally designed based on a single-chip microcomputer or a PC/104 bus controller. It has the characteristics of good compatibility with PC, low...[Details]
AD8205 is
a single-supply high-performance differential
amplifier
launched by
Analog
Devices of the United States
. The typical single-supply voltage is 5V, and its common-mode volta...[Details]
1 Introduction
PROFIBUS is an international, open, and manufacturer-independent fieldbus standard. It is widely used in manufacturing automation, process industry automation, and automatio...[Details]
On the afternoon of July 10, Beijing time, Taiwan's largest chip designer MediaTek expects its smartphone chip shipments to grow by double digits in the third quarter of this year, and the company is ...[Details]
General LED lighting has a current limiting resistor in the driving circuit, and the power consumed by the resistor has nothing to do with the LED light emission. In order to improve efficiency, a...[Details]
Flooded Batteries
This battery developed in Germany can be used to power flashlights, strobe lights and toys as long as it is filled with water. This battery can be stored for 50 years and can...[Details]
Introduction
Liquid crystal, as a display device, is widely used in low-power products such as instruments, meters, and electronic equipment with its unique advantages. In the past, the displ...[Details]
introduction
At present, measuring instruments are developing towards networking, and each individual embedded instrument will become a node on the Internet. This system realizes the network...[Details]
Introduction
As the country increases its efforts to control the atmospheric environment, motorcycle emission regulations will become stricter year by year, and motorcycles that do not meet the...[Details]
0 Introduction
Under normal circumstances, the three-phase power in the power system is symmetrical, and they meet certain amplitude and phase conditions; but when the load changes, the syst...[Details]
The above is to use MB1404 as a stereo composite signal transmitter. You can use the internal high-frequency amplifier and oscillator or not! According to my experience, I still recommend beginners...[Details]
1 Introduction
With the rapid economic development, my country's electricity demand has been growing at a rate of more than 20% per year. According to the current economic development trend an...[Details]
Cars equipped with xenon headlights are already common on the road. Whether they are standard equipment on high-end cars or embellishments on modified cars, xenon lamps are gradually becoming a sym...[Details]