Part Number

Search

36FCD10

Description
Power line filter 36a phnx-phnx contac flange mount
CategoryThe connector   
File Size734KB,5 Pages
ManufacturerAll Sensors
Environmental Compliance
Download Datasheet Parametric Compare View All

36FCD10 Online Shopping

Suppliers Part Number Price MOQ In stock  
36FCD10 - - View Buy Now

36FCD10 Overview

Power line filter 36a phnx-phnx contac flange mount

36FCD10 Parametric

Parameter NameAttribute value
MakerAll Sensors
Product CategoryPower line filter
RoHSyes
Voltage rating480 VAC
Current rating36 A
filter typePower Line
filterYes
Leakage current9.8 mA
EncapsulationBulk
series connectionFCD (6-50 Amp)
Entrance typePower Line
Corcom Product Guide
Catalog: 1654001
Issue Date: 08.2010
3-phase Delta External Power Line Filter for Frequency Converters
FCD Series
UL Recognized
6FCD10
FCD Series
• Suitable to meet the latest EMC standards
• Insulated safety terminals
• Suitable for EMC troubleshooting in the field
• Very high attenuation
• High insertion loss
• BS models optimized for very high insertion loss
• BS models suitable for infeed/regenerative (ER)
applications
• Touch safe terminals provide easy connections
and prevent inadvertent contact for safety in the
most demanding applications
Specifications
Maximum leakage current
voltage drop to virtual N to PE/V:
6FCD10:
12 & 16FCD10:
25, 36 & 50FCD10:
12 & 16FCD10B:
25& 36FCD10B:
50FCD10B:
80 & 110FCD10B:
150FCD10B:
180 & 230FCD10B:
FCD10BS:
Hipot rating (one minute):
Line to Ground:
Line to Line:
Rated Voltage (max):
Phase to Phase:
Phase to Neutral / Ground:
Operating Frequency:
Rated Current:
.26 mA/V
.45 mA/V
.52 mA/V
.46 mA/V
.52 mA/V
.57 mA/V
.62 mA/V
.63 mA/V
.92 mA/V
3.25 mA/V
2250 VDC
1450 VDC
480 VAC
277 VAC
50/60 Hz
6 to 230A
Ordering Information
150 FCD 10 BS -95
Terminal Block Option
-95 – 95mm terminal block
available on 150A only
omit for standard terminals
Filter Type
B – Single stage
BS – High performance
Single stage.
Omit for dual stage
Input / Output Style
10 – Terminal Block
FCD Series
Current Rating
6, 12, 16, 25, 36, 50, 110,
150, 180 or 230A
118
Operating Ambient Temperature Range
(at rated current Ir):
-10°C to +40°C
In an ambient temperature (Ta) higher than +40°C
the maximum operating current (Io) is calculated as
follows: Io = Ir
√(85-Ta)/45
Electrical Schematics
6FCD10
Power line
Device
PE
PE
Dimensions are in inches and millimeters unless otherwise specified. Values in italics
are metric equivalents. Dimensions are shown for reference purposes only.
Specifications subject to change.
For email, phone or live chat, please go to
tycoelectronics.com/help
corcom.com

36FCD10 Related Products

36FCD10 6FCD10 16FCD10 50FCD10
Description Power line filter 36a phnx-phnx contac flange mount Power line filter 6A phnx-phnx contac flange mount Power line filter 16a phnx-phnx contac flange mount Power line filter 50a phnx-phnx contac flange mount
Maker All Sensors All Sensors All Sensors All Sensors
Product Category Power line filter Power line filter Power line filter Power line filter
RoHS yes yes yes yes
Voltage rating 480 VAC 480 VAC 480 VAC 250 VAC
Current rating 36 A 6 A 16 A 50 A
Leakage current 9.8 mA 4.9 mA 9.8 mA 7 mA
series connection FCD (6-50 Amp) FCD (6-50 Amp) FCD (6-50 Amp) FCD
filter type Power Line Power Line Power Line -
filter Yes Yes Yes -
Encapsulation Bulk Bulk Bulk -
Entrance type Power Line Power Line Power Line -
Does CCS6.0 support DSP2407?
Can DSP2407 use CCS6.0? Is there a big difference with 28 series?...
张锋 Microcontroller MCU
How to write a test bench
I would like to ask for advice from all the experts. I have recently been learning to use the simulation software modelsim. Is there a fixed format for writing test programs?...
cpmg FPGA/CPLD
A test software app store, share it with you
http://www.superyun.com/Appstore/index.html You can download it directly to your phone. It contains software and game programs. You can try it. It will be improved in the later stage. Please tell us w...
zhangjingrui Embedded System
Ask a question about driver installation
I can find the driver file, but it cannot be installed normally. Is this a problem with the inf file or the sys driver? Which routines (such as driverentry, MPInitialize) should be implemented to ensu...
jebelwoo Embedded System
IoT development board comparison——by fyaocn
[size=4]IoT Development Board Pairing - by fyaocn [url=https://bbs.eeworld.com.cn/thread-498234-1-1.html]IoT Development Board Pairing Series 1 - Overview[/url] [url=https://bbs.eeworld.com.cn/thread-...
okhxyyo RF/Wirelessly
Ultrasonic transducer impedance matching problem
Hello everyone, I recently encountered an impedance matching problem about ultrasonic transducers. The equivalent circuit of the ultrasonic transducer is shown in Figure 1.Figure 1 Equivalent model of...
榆枫 Analog electronics

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1781  1411  1452  1210  216  36  29  30  25  5 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号