WL-4A112

Description
Basic/quick action/limit switch limit switch
CategoryTopical application    Mechanical and electrical/engineering/automation   
File Size4MB,43 Pages
ManufacturerAll Sensors
Environmental Compliance
Download Datasheet Parametric View All

WL-4A112 Online Shopping

Suppliers Part Number Price MOQ In stock  
WL-4A112 - - View Buy Now

WL-4A112 Overview

Basic/quick action/limit switch limit switch

WL-4A112 Parametric

Parameter NameAttribute value
MakerAll Sensors
Product CategoryBasic/Snap Action/Limit Switch
RoHSyes
Two-circuit Limit Switch/Long-life Two-circuit Limit Switch
WL/WLM
Wide Range of Two-circuit Switches;
Select One for the Operating
Environment/Application
A wide selection of models are available, including the
overtravel models with greater OT, indicator-equipped
models for checking operation, low-temperature models,
heat-resistant models, and corrosion-proof models.
Microload models are added to the product lineup.
Approved standards: EC/IEC, UL, CSA, CCC (Chinese
standard).
Contact your OMRON representative for information on
approved models.
Be sure to read
Safety Precautions
on page 39 to 42 and
Safety Precautions for All Limit Switches.
CSM_WL_WLM_DS_E_6_1
Features
Standard Models
Many Variations in Standard Limit Switches
Features Common to All Models
DPDB Operation
The double-pole, double-break structure ensures circuit braking.
1
Za
(NO)4
3(NO)
2
4
3
A Wide Range of Models
The WL Series provides a complete range of Limit Switches with a
long history of meeting user needs. Select environment-resistant
specifications, actuators for essentially any workpiece, operating
sensitivity matched to the workpiece, operation indicators to aid
operation and maintenance, and various wiring specifications.
(NC)1
2(NC)
Load
Load
Environment-resistant Models
Select from Six Types of Environment Resistance
The series includes Airtight Switches, Hermetic Switches, Heat-
resistant Switches, Low-temperature Switches, Corrosion-proof
switches, and Weather-proof Switches. Select the one required by the
onsite environment.
Degree of Protection; IP67
O-rings, cover seals, and other measures provide a water-proof, drip-
proof structure (IP67).
Approved Standards to Aid Export Machines
Various WL/WLM switches are approved by UL, CSA, TÜV, EN/IEC,
and CCC making them ideal for export machines.
Spatter-prevention Models
Excellent Performance on Arc Welding Lines or Sites with
Spattering Cutting Powder
High-precision Models Available in All Switch Types;
Ideal for Position Control
High-precision models achieve a very small movement to operation
(approx. 5°) and a repeat accuracy that is twice that of basic models.
Ideal for Welding Sites
Stainless steel and resins that resist adhesion of spatters are used to
prevent troubles caused by zinc powder generated during welding.
Long-life Models
Mechanical Endurance of 30 Million Operations
Operation Indicators for Easier Daily
Inspections*
Confirm operation with a neon lamp or LED for
easier startup confirmations and maintenance.
* Operation indicators are provided on Indicator-
equipped switches, Spatter-prevention Basic
Switches, and Long-life Basic Switches.
Long-life Models for High-frequency Applications
Long life has been achieved by increasing the resistance to friction
and creating better sliding properties in the head mechanism. Greater
visibility is provided when setting with a fluorescent display for setting
the stroke.
Operation
indicator
Models with Connectors to Reduce Wiring
Reduce wiring with one-touch connection. Models with direct-wired
and prewired connectors that make Switch replacement easier are
also available.
1
Application of Chemical Vapor Deposition in Back-end Process of Integrated Circuit Manufacturing
Application of Chemical Vapor Deposition in Back-end Process of Integrated Circuit Manufacturing[Source: "Semiconductor Technology"] [Author: Yi Wanbing1,2,3, Tu Ruineng1, Zhang Bingyi1, Wu Jin1, Mao ...
fighting PCB Design
Drawing AD schematic diagram
When drawing AD schematics, I don't know how to draw common mode inductors. If I encounter components that are not in the system library, but are difficult to draw in the schematic library, what shoul...
NJMKL PCB Design
Application of Computer Control Technology in Tire Vulcanization System
Abstract: The central control PLC, intelligent temperature controller and pressure instrument are used to replace the original three-pin recorder to realize closed-loop control and recording of extern...
frozenviolet Industrial Control Electronics
Digital Signal Processing Exercises Answers
Solutions to exercises in "Digital Signal Processing" Solutions to exercises in Oppenheim's "Digital Signal Processing"....
songbo DSP and ARM Processors
BulkUSB problem, urgent.
I would like to ask if there are any brothers who use the bulkusb that comes with DDK? After I compiled and installed it, it prompted an exclamation mark and could not be installed correctly. I don't ...
liyang203 Embedded System
SD card reading and writing problems
The pocket experiment platform of g2553 has a 2G TF card inserted. After downloading the official routine, the TF card cannot be read or written. (What does it mean when the routine says that only the...
zjw158 Microcontroller MCU

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1533  2364  2126  2525  1111  31  48  43  51  23 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号